GlucoMen
®
areo 2K - User Manual - MASTER
4801002/19210 (w) x 300 (h)
I - BLACK C
Страница 1: ...e Self Monitoring System 2 System overview 2 1 Meter FRONT TEST STRIP PORT UP DOWN BUTTONS ENTER BUTTON TEST STRIP PORT Test strip should be inserted here ENTER BUTTON Press and hold for 2 seconds to access meter memory 6 1 or longer 4 seconds to enter setup mode while not testing 7 UP DOWN BUTTONS Press or to scroll through different options and or values BACK BATTERY HOLDER NFC ANTENNA DATA TRAN...
Страница 2: ...lucoMen areo 2K meter use GlucoMen areo Sensor or GlucoMen areo β Ketone Sensor only Do not use other test strips it causes inaccurate test results Do not use test strips after their expiry date The expiry date is either written on the test strip vial next to the symbol glucose sensor or on the foil pouch β ketone sensor For accurate test results allow the meter and test strips to adjust to the su...
Страница 3: ...mode simultaneously press the UP DOWN buttons for two seconds while the drop icon is blinking on the screen Once CTL mode is enabled CTL mark is displayed together with ctl message written in bigger characters on the main screen c Gently shake the control solution vial before testing Discard a drop before use Squeeze a drop of control solution onto a clean hard dry surface d Touch the control solu...
Страница 4: ...testing Discard a drop before use Squeeze a drop of control solution onto a clean hard dry surface d Touch the control solution drop with the tip of the test strip until the check window is full A beeper will sound if enabled as the countdown timer starts on the screen NOTE The test will not start if you apply your control solution directly to the check window The test starts when the meter detect...
Страница 5: ...F You can turn it on by pressing or Press to confirm the selection and move on to the next step c Press or to select the hour Press to confirm the selection and move on to the next step d Press or to select the minutes Press to confirm the selection and move on to the alarm 2 setting e Set alarm 2 and 3 by following steps b to d After you have finished setting all alarms press to return to the set...
Страница 6: ...o not reset time and date all subsequent test results will be stored with the incorrect date and time Dispose of old batteries according to local environmental regulations CAUTION Improper use may cause explosion or leakage of flammable liquid Do not expose the batteries to extremely high temperatures Do not expose the batteries to extremely low air pressure 9 Troubleshooting 9 1 HI and LO message...
Страница 7: ...emperature 5 to 45 C 41 to 113 F for glucose testing 10 to 40 C 50 to 104 F for β ketone testing Relative Humidity 20 to 90 no dew condensation for glucose testing 85 for β ketone testing Meter Storage Conditions Temperature 20 to 50 C 4 to 122 F Relative Humidity 20 to 90 Control Solutions Storage Temperature 4 to 30 C 39 2 to 86 F Operating environment The meter complies with applicable electrom...
Страница 8: ...l and electronic equipment The meter is in compliance with Directive 2014 53 EU on radio equipment The full text of the EU Declaration of Conformity is available at the following internet address www red menarinidiagnostics com 11 Warranty Your GlucoMen areo 2K meter is guaranteed to be free of material and workmanship defects for 2 years from the date of purchase except as noted below If at any t...
Страница 9: ...48010 02 19 GlucoMen areo 2K User Manual MASTER 48010 02 19 210 w x 300 h I BLACK C ...