A.J.Antunes roundup MS-150 Скачать руководство пользователя страница 15

15

P/N 1010881 Rev. F 03/12

replaceMenT parTS (continued)

1  0010159  Filter Assy., Water Tank  1
2  7000370 Relay 

1

3  4060374  Ground Lug, Copper  1
4  0011802  Pump/Tube Assy.,  

 

 

24VAC  

 

5  7000391  A/C Line Isolator Board 1 
6  7000237  Top Cover Assy.  

 

 

(Incl. #41 & #42) 

7  0011314  Steam Vent Assy. 

1

8  0021131  Floor/Chassis Weld.  1
9  0012547  Access Cover Weld.   1 

10  7000246  Generator, 230V 

1

11  0300129  Stud, Cover Hold Down 1
12  040P138*  Locknut, 1/2” 

1

13  040K251  Strain Relief (Incl. #12)  1
14  05P2199* Spacer 

2

15  0503431  Diffuser, Steam 

1

16  4050229  Line Filter 

1

17  0503433  Cover, Generator 

1

18  0503434  Cover, End Housing  1
19  0503435  Retainer, Thermocouple 1
20 0503988 Spatula 

1

21  0505733  Liner, Cavity  

1

22  0504248  Bracket - Capacitor  1
23  0503472  Bracket, Hi-Limit  

  

Support 

24  0700453  Power Cord, CEE 7/7   1 

 

 

(Mfg. No. 9100429) 

 

0700437  Power Cord, IEC-309  1 

 

 

(Mfg. No. 9100421)

25  00203-0091 Assy. Sub, MSFilter  1
26  100P967  Label, Marking 

1

27  1001036  Label, Control Panel   1
28  2000203  Tube, Restrictor, 1/4”  1

29  0503429  Support, Generator   1 

  

Upper. 

30  7000849  Silicon Tube Kit,  

 

 

Water Pump 

 

31  2040106  Adapter, Tube/Hose  1
32  2040145  Elbow, Female,  

 

 

1/8" x 1/4" 

33  2040146  Tee, Female,  

 

 

1/8" x 1/4" 

34  7000693  Water Fitting Kit  

 

 

(Incl. #28, 31, 32 & 33)

35  210K108  Foot, Rubber (4 Pack)  1
36  2100119  Handle, Spatula 

1

37  4050180  Heat Sink 

1

38  0011370  2” Leg Kit (Incl. #35)  4
39  2100118  Guard, Handle 

40  0503536  Drip Pan  

1

41  2100249  Guard, Knob 

1

42 2100273 Knob 

1

43  211P101  Clamp, Hose, 3/8" 

1

44  211P195  Clamp, Hose 

1

45  338P102*  Bolt, Handle Mounting  1
46  7000446  Generator Tube,  

  

3-5/8" 

 

47  2100279  Guard, Spatula 

 

 

(not shown)

48  300P102*  Nut, Speed, “U”, #8-32  2
49  304P105*  Nut, Hex, KEPS,  

 

 

#4-40, Zinc 

50  306P101*  Nut, Hex, #6-32 

2

51  306P105*  Screw, Machine,  

 

 

#6-32 x 1/2"  

52  306P123*  Screw, Machine,  

 

 

#6-32 x 7/8” 

53  306P130*  Nut, Hex, KEPS, #6-32 2

54  306P134*  Screw, Machine,  

 

 

#6-32 x 3/8"

55  308P103*  Screw, Machine,  

 

 

#8-32 x 1/4"

56  4070078  Control Board,  

  

Temperature/Timer, 

 

 

 

24V, 50/60 Hz 

57  308P105*  Screw, Machine,  

 

 

#8-32 x 1/2" 

58  308P120*  Screw, Machine,  

 

 

#8-32 x 5/8" (sltrshd) 

59  308P124*  Screw, Machine,  

 

 

#8-32 x 1/2" (one-way) 

60  308P143*  Nut, Hex, KEPS, #8-32 2
61  310P136*  Screw, Machine,  

 

 

#10-32 x 1-1/4"  

  

(splanhd) 

62  310P149*  Screw, Machine,  

 

 

#10-32 x 7/8" 

63  7000136  Terminal Block, 3-Pole 1
64  325P170*  Nut, Wing, 1/4-20 

1

65  7000542  Rocker Switch, 

 

 

Power On/Off 250V 

66  4010166  Switch, Momentary   1 

  

(Green) 

 

4010190  Switch, Momentary   1 

  

(White)

67  7000319  Transformer,  

  

115-230/24/12V 

68  7000135  Thermostat, Hi-Limit  1
69  4050214  Thermocouple, Type-K  1
70  406P107  Cable Tie (not shown) 3

* Only available in quantities of 10.

 Item part No.  Description 

Qty.

 Item part No.  Description 

Qty.

 Item part No.  Description 

Qty.

Содержание roundup MS-150

Страница 1: ...P N 1010881 Rev G 03 12 MS 150 owner s manual miracle steamer Manufacturing Numbers 9100421 9100429 www ajantunes com POWER UP READY DOWN PROGRAM START STOP ...

Страница 2: ...tandards This unit has been tested at the factory to ensure dependable trouble free operation Warranty Information Please read the full text of the Limited Warranty in this manual If the unit arrives damaged contact the car rier immediately and file a damage claim with them Save all packing materials when filing a claim Freight damage claims are the respon sibility of the purchaser and are not cov...

Страница 3: ...person in order to avoid a hazard Do not modify the power supply cord plug if it does not fit the outlet have a proper outlet installed by a qualified electrician Do not use an extension cord with this appliance Electrical ground is required on this appliance Check with a qualified electrician if you are unsure if the appliance is properly grounded If a chemical cleaner is used be sure it is safe ...

Страница 4: ...IEC 309 16 Amp 230 Volt Pin Sleeve MS 150 9100429 230 3300 14 4 50 60 CEE 7 7 16 Amp 250 Volt Model Mfg No Agency Approvals MS 150 9100421 9100429 A S D L I S T E CM O I N NIT A T C T I S L US E D D L I S T E C US INTERTEK Model No Width A Depth B Height C MS 150 9100421 9100429 21 533 mm 21 3 8 543 mm 10 1 4 260 mm RE AD Y A C B ...

Страница 5: ... Liner Figure 1 Washing Parts Figure 2 Assembling Handle Bolt Handle Spatula Handle Guard Wire Trivet Electrical Plug the power cord into the appropriate power outlet Refer to the specification plate for the proper voltage 1 Place the unit on a sturdy level table or other work surface 2 Turn off the power 3 Ensure that the line voltage corre sponds to the stated voltage on the units specification ...

Страница 6: ... the control from OPERATION to PROGRAM mode 3 To change the Total Cycle Time in minutes press or to change the time 4 Press and release again and press or to change the Total Cycle Time in seconds 5 To change the SHO factory settings make sure the control is in PROGRAM mode then press and hold both and simultaneously for 1 2 seconds and release SHO will be displayed 6 Press and release and then pr...

Страница 7: ...ARNING Turn the power off unplug the power cord and all the unit to cool down before performing any service or maintenance WARNING Be sure to follow all the precautions proce dures and safety steps listed in the Important Safety Information section of this manual Steam Vent Spatula Drip Pan Spatula Liner Top Cover Figure 6 Daily Cleaning MS 150 Generator Temperature The unit has three Generator te...

Страница 8: ...le 4 Clean the Filter by running it under tap water Replace the Filter if the screen is torn or damaged 5 Reinstall the Filter Stem into the bot tom hole of the tank Figure 8 6 Fill the Water Tank close the Tank Door and test the unit NOTE Do NOT overfill the unit s water tank Only fill the tank to 90 full 7 Using a sponge or a dry towel remove the delimer solution from the Generator surface then ...

Страница 9: ...s inoperable Thermocouple is inoperable Control Board is inoperable Steam Generator is inoperable Loose burnt or broken wires in circuit The unit s main electrical panel circuit breaker trips Damaged receptacle plug or cord a loose connec tion or an internal component failure Turn the power off allow the unit to cool to room temperature and then restart the unit Contact your maintenance person or ...

Страница 10: ...is manual Generator surface is bare Generator surface must have a thin calcium mineral coating for proper steaming Refer to the Maintenance section of this manual Generator Steam Ports are restricted Clean the Steam Ports as described in the Maintenance section of this manual Generator Cover is warped or loose Verify that the Generator Cover Wing Nut is tight If noticeable steam escapes around the...

Страница 11: ...11 P N 1010881 Rev F 03 12 Wiring Diagram ...

Страница 12: ...12 P N 1010881 Rev F 03 12 RE AD Y 64 11 18 20 45 36 21 66 65 6 7 8 10 12 13 24 62 38 35 70 57 54 54 54 42 41 40 39 29 17 15 57 Replacement Parts ...

Страница 13: ...33 35 210K108 Foot Rubber 4 Pack 1 36 2100119 Handle Spatula 1 37 4050180 Heat Sink 1 38 0011370 2 Leg Kit Incl 35 4 39 2100118 Guard Handle 1 40 0503536 Drip Pan 1 41 2100249 Guard Knob 1 42 2100273 Knob 1 43 211P101 Clamp Hose 3 8 1 44 211P195 Clamp Hose 1 45 338P102 Bolt Handle Mounting 1 46 7000446 Generator Tube 2 3 5 8 47 2100279 Guard Spatula 1 not shown 48 300P102 Nut Speed U 8 32 2 49 304...

Страница 14: ...14 P N 1010881 Rev F 03 12 Replacement Parts continued 43 31 32 33 23 55 28 46 4 49 43 46 30 30 30 RE AD Y 32 57 48 67 59 60 51 49 63 68 55 49 19 55 5 16 22 25 56 69 37 2 26 RE AD Y RE AD Y 34 43 1 9 55 ...

Страница 15: ...33 35 210K108 Foot Rubber 4 Pack 1 36 2100119 Handle Spatula 1 37 4050180 Heat Sink 1 38 0011370 2 Leg Kit Incl 35 4 39 2100118 Guard Handle 1 40 0503536 Drip Pan 1 41 2100249 Guard Knob 1 42 2100273 Knob 1 43 211P101 Clamp Hose 3 8 1 44 211P195 Clamp Hose 1 45 338P102 Bolt Handle Mounting 1 46 7000446 Generator Tube 2 3 5 8 47 2100279 Guard Spatula 1 not shown 48 300P102 Nut Speed U 8 32 2 49 304...

Страница 16: ...eding maximum weight capacity 4 lbs This warranty does not cover water contamination problems such as foreign material in water lines or inside solenoid valves It does not cover water pressure problems or failures resulting from improper incorrect voltage supply This warranty does not cover Travel Time Mileage in excess of 2 hours 100 miles 160 km round trip from the nearest authorized service age...