troublesHootING (continued)
Problem
Possible Cause
Corrective action
The unit displays the following mes-
sage:
Upper Sensor Fail
Lower Sensor Fail
Note
: A thermocouple which has
become grounded will cause erratic
controller behavior
The Thermocouple in the Platen cir-
cuit has failed.
The toaster cannot be operated
with this type of failure. Contact
your Authorized Service Agency for
service.
A control relay has a short or the
Thermocouple is not pushed into the
Platen correctly.
The toaster will open the C1
contactor, disabling the toaster.
Contact your Authorized Service
Agency for service.
The overtemp thermocouple tempera-
ture is greater than 250º F (121º C)
but less than 350º F.(176º C).
There is a problem with the main
convection blower.
The toaster will shut down. Allow
the toaster to cool down and
restart. If this condition persists,
contact your Authorized Service
Agency for service.
The overtemp thermocouple tempera-
ture is greater than 350 F or an open
thermocouple condition exists.
There is a problem with the main
convection blower.
The toaster will shut down. Allow
the toaster to cool and then restart.
If this condition persists, contact
your Authorized Service Agency for
service.
The unit is running too hot.
Cooling Fan failure.
The toaster will operate normally
until the compartment ambient
temperature exceeds 160º F. (71º
C) At this point, the toaster will shut
down. Contact your Authorized
Service Agency for service.
The unit displays the following mes-
sage:
WARNING! Power Fault
Unplug now!!!
Contactor and control relay failures.
Unit has detected IR current or rising
Platen temperature with the power
off.
Immediately unplug the power cord
and call your Authorized Service
Agency for service. The unit must
not be operated with this kind of
failure.