Troubleshooting
Trouble
Possible cause
Suggested remedy
Engine will not start
1. Low on fuel or oil content
1a. Add Fuel ( ensure fuel is fresh)
1b. Fill oil in motor until oil runs out
of filler hole
2. Generator not sitting on level ground.
2. Move generator to level ground.
Oil sensors will detect low oil if the
generator is not level.
3. Ignition switch in “Off” position
3. Turn the ignition to the ‘START’ position
on electric start models, or ‘ON’ position
if manually starting.
4. Faulty spark plug
4. Replace or clean spark plug
5. Choke in wrong position
5. Adjust choke accordingly
6. Fuel shut-off valve in closed position
6. Open fuel shut-off valve
7. Unit loaded during start-up
7. Remove load from unit
8. Spark plug wire loose
8. Attach wire to spark plug
No electrical output
1. Faulty receptacle
1. Have service centre replace receptacle
2. Dirty or stale fuel in carburettor bowl.
2. Open the drain screw on the carburetor
bowl and allow the fuel to drain for
approx 5 sec. Close drain and retry start
3. Circuit breaker turned off
3. Depress or lift to reset
4. Worn brushes
4. Have service centre replace brushes
5. Faulty power cord
5. Replace cord
Repeated circuit
breaker tripping
1. Overload
1. Reduce load
2. Faulty cords or equipment
2. Check for damaged, bare, or frayed
wires on equipment. Replace.
3. Check rating label of the appliance.
3. Compare the suggested limits on similar
appliances in the section of this manual,
“
What can I use the generator for?”