16
Troubleshooting
Trouble
Possible cause
Suggested remedy
Engine will not start or will
not keep running
1. Low on fuel/oil content
1. Add fuel/oil mix
2. Ignition switch in “Off” position
2. Turn to “ON” position
3. Faulty spark plug
3. Replace spark plug
4. Choke in wrong position
4. Adjust choke accordingly
5. Fuel tap in closed position
5. Open fuel tap
6. Unit loaded during start-up
6. Remove load from unit
7. Spark plug wire loose
7. Attach wire to spark plug
8. Dirty fuel filters
8. Clean filters as per instructions
No electrical output
1. Faulty receptacle
1. Have service centre replace receptacle
2. Circuit breaker kicked out
2. Depress and reset
3. Defective capacitor
3. Have service centre replace capacitor
4. Faulty power cord
4. Replace cord
Repeated circuit breaker
tripping
1. Overload
1. Reduce load.
2. Faulty cords or equipment.
2. Check for damaged, bare, or frayed wires
on equipment. Replace.
Generator overheating
1. Generator overloaded.
1. Reduce load
2. Insufficient ventilation.
2. Move to adequate supply of fresh air.
Содержание A750
Страница 17: ......