26
M512-3 Juggler : User Guide
© 2021 7thSense
Connect a Juggler Optical Data Bus
Connect a Juggler Optical Data Bus
Jugglers in a system should be racked adjacent to each other, since optical connections must be
short and loop freely. If you are using multiple Jugglers on a data bus, make these connections first,
before inputs and outputs; they can become quite congested with many units.There are two bus
configurations, 4 and 8 lane, with each lane having a capacity of up to the equivalent of UHD 60fps 10-
bit 4:4:4.
Please note
that as a critical component, optical cables used should be supplied or approved by
7thSense. Cables do not need to be short but the minimum bend radius of a free-hanging cable
should be not less than 10 times the cable outside diameter.
This page covers the physical cabling. For an explanation of how this works, and the use of the data
bus in the Compere software, see:
Ø
Bus Connections in a Juggler System
8-Lane ‘Full’ Bus
With the MPO (Multi-Fibre Push-on) optical fibre option, twice the bandwidth is available. Each fibre-
optic cable carries 8 lanes, 4 in each direction:
Units are daisy-chained unit to unit, 1 to 2 and loop back from the last unit to the first in the same way.
Cables
Use MTP/MPO 12-fibre 50/125 patch cables, type B, Female to Female.
103
Содержание Pixel Processing Juggler
Страница 1: ...Pixel Processing Juggler M512 3 User Guide ...
Страница 12: ...12 M512 3 Juggler User Guide 2021 7thSense What Juggler Can Do ...
Страница 23: ...23 M512 3 Juggler User Guide 2021 7thSense Rear Panel Connections ...
Страница 72: ...72 M512 3 Juggler User Guide 2021 7thSense Network Configuration ...
Страница 147: ......