7th Sense Medialon MAS Pro Dante D Скачать руководство пользователя страница 2

 

 

 

Connecting External Equipment 

To ensure best performance from the server and compliance with relevant EMC regulations, this 

equipment should only be used with high-quality shielded data and signal cables. 
Only equipment and accessories approved to IEC 60950-1 and SELV circuits may be 

connected to the server. All equipment and accessories shall comply to the relevant standard 

for the server’s port to which it is connected. 

Environment 

General 

This equipment is intended for use in a commercial (not domestic) environment and should be 

operated in a clean, dust free area (e.g. a server room).  
The equipment is intended for operation in benign environments; that is, not subject to 

corrosive or explosive atmospheres, moisture or flammable gases. The server is non-protected 

against ingress of liquid (IPx0). The server is not designed to be subject to excessive 

mechanical shock or vibration. 
This equipment is not suitable for use in locations where children are likely to be present. 

 

Only used at altitude 

not exceeding 2000 m 

 

Only used in not-tropical 

climate regions 

Thermal 

Do not block any of the unit’s air vents and ensure the ambient temperature around the unit is 

compatible with the environmental characteristics stated below. 
Particularly when mounted in a rack cabinet with front or rear doors the ambient temperature 

around the unit may be higher than the ambient room temperature. 

Electrical 

Before connecting power to the MAS Pro Dante, ensure the electricity supply is compatible 

with the electrical ratings shown here and on the server product label. The unit shall not be 

connected to an IT (unearthed neutral) power distribution system and the mains socket-outlet 

used shall connect to the building installation ground. 
The server is connected to and disconnected from the mains supply with the IEC 60320 power 

connector on the rear of the unit.  

Maintenance 

Air Filter 

A user-serviceable air filter is located on the server’s front panel. It is important to remove and 

clean or replace the filter periodically to avoid overheating. 
MAS Pro Dante is supplied with one spare filter pad, others can be provided by your supplier. 

It should not be run without filters, since accumulations of dust inside the server can affect 

performance.  

Cleaning 

External casing and the front panel should be carefully wiped with a soft cloth and antistatic 

solution. 

Server internal maintenance 

Internal maintenance must only be undertaken by suitable qualified service personnel. 

Warning

: Do not operate the server with any covers removed as the air flow through 

the unit may be compromised leading to overheating. 

Warning

: Motherboard CMOS battery replacement: Danger of explosion if incorrect battery 

used or battery incorrectly installed. Contact your supplier for further instructions. 

Any alterations to the product’s specification, including additional/alternative 

components, BIOS changes, overclocking, etc., may invalidate the warranty or impact 

the server’s performance. Additionally, such changes or modifications could cause equipment 

no longer to comply with the relevant EMC regulations, and void the user’s authority to operate 

the equipment. If in doubt, please contact your supplier. 

Electrostatic discharge (ESD) 

When handling electronic assemblies, take precautions to avoid electrostatic discharge (ESD) 

causing damage. Precautions should include the wearing of an ESD protective wrist strap and 

using antistatic bags for electronic assemblies when not installed in a server. 