![7starlake SKY12-X06 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/7starlake/sky12-x06/sky12-x06_user-manual_3070549006.webp)
6
Chapter 3: Specification
12.1” TFT LCD Display & Resistor Touch screen
Resolution
1024x768 XGA
Brightness
1300 Nits
Aspect Ratio
4:3
Contrast Ratio
900
Touch Panel
Glass-Film-Glass 5-Wire resistor touch panel (Optional)
System SPEC
Dual Mode
Day Mode: Ultra-Brightness 1300 nits; Night Mode: NVIS (Dimmable under 1% Nits)
Function key
7 Soft Touch Buttons, including :
3 for OSD (Brig, Brightness-, Blackout);
3 for Programmable;
1 for power button (On/Off)
DC-IN
18V ~ 36 V, 28Vdc
Connectors
DC-IN
Amphenol TV07RW-11-54P
IO Ports
X1:DVI (Amphenol TV07RW-13-35S);
X2:2xUSB (Amphenol TV07RW-13-98S)
Applications
Applications
Marine, Naval, Ground and Airborne environment.
Physical
Dimension
310 x 280 x 90 mm (W x D x H)
Weight
TBD
Finish
Anodic aluminum oxide
Chassis
Aluminum Alloy, Corrosion Resistant.
Ingress Protection
IP65 Dust /water Proof
MIL Compliance
MIL-STD-810G (Operation Test)
Low Temp.
Method 502.5 Procedure 2
Exposure(24h x 3 cycle) at -10
℃
min.
High Temp.
Method 501.5 Procedure 2
60
º
C for 2 hrs after temperature stabilization.
Humidity
Method 507.5 Procedure 2
RH -95%. Test cycles: ten 24-hrs , functional test after 5th and
10th cycles
Vibration
Method 514.6 Category 20
10-500Hz 1.04Grms Test duration: 1 hr x 3 axis (total 3 hrs)
Shock
Method 516.6 Procedure 1
20G, 11mSec, 3 per axis
MIL-STD-810G (Non-Operating Tests)
Low Temp.
Method 502.5
Exposure(24h x 7 cycle) at -20
℃
min.
High Temp.
Method 501.5 Procedure 1
71
º
C for 2 hrs after temperature stabilization.
Vibration
Method 514.6 Category 24
200 to 2000Hz Test duration: 1hr per axis; rms = 7.7 gs
Shock
Method 516.6 Procedure 1
20G, 11mSec, 3 per axis