Item 

Description 

PN 

ITA Module 

 

TriPaddle Signal Module, 96 Position 

 

VP510108126 

 

ITA Tripaddle pin 

 

 

TriPaddle Signal, Contact, 7 Amp, 20-

24 AWG, 30μ" Gold 

 

VP610110108 

 

 

 

 

Содержание YAV904X8

Страница 1: ...X8 Note Before you begin complete the software and hardware installation procedures applicable to your application Note the guidelines in this document are specific to the YAV904X8 The other components in the system might not meet the same safety ratings Refer to the documentation of each component in the system to determine the safety and EMC ratings for the entire system ...

Страница 2: ...LAYOUT AND DIMENSIONS 5 5 RELAY DISTRIBUTION 6 6 PINOUT FRONT 7 7 CONNECTOR PINOUT REAR 8 8 LED BEHAVIOUR 9 9 SWITCH CONFIGURATION 9 10 HARDWARE SPECIFICATIONS 10 11 OPERATION 11 11 1 PHI6 EXPLORER soft interface 11 12 LOW LEVEL CAN COMMANDS 12 13 ACCESSORIES 12 14 UNPACKAGING AND INSTALLING 13 ...

Страница 3: ...t when such failure is due to the parameters incorrect programming The product described in this manual can be configured to comply with the ruling of different countries The manufacturer does not hold any responsibility if the company installing it does not configure it according to the legal commercial or security prescriptions that may be in force in the place of installation or otherwise agree...

Страница 4: ...itation and measuring for example load cells The board is organized in 4 groups of 8 bipolar relays with double contact access to each branch Therefore there is the possibility to set up different multiplexer configurations adding wiring connections inside the test fixture Set up Connections inside the fixture 1 x 32 relay multiplexer Join pin 30 to pin 36 Join pin 31 to pin 37 Join pin 63 to pin ...

Страница 5: ...4 LAYOUTAND DIMENSIONS All dimensions are in millimetres ...

Страница 6: ...5 RELAY DISTRIBUTION ...

Страница 7: ...0L 2 45 Row B Bit P0H 2 77 Row C Bit P1L 2 14 Row D Bit P1H 2 46 Row B Bit P0H 2 78 Row D Bit P1H 2 15 Row A Bit P0L 3 47 79 Row C Bit P1L 3 16 Row A Bit P0L 3 48 Row B Bit P0H 3 80 Row C Bit P1L 3 17 Row D Bit P1H 3 49 Row B Bit P0H 3 81 Row D Bit P1H 3 18 Row A Bit P0L 4 50 82 Row C Bit P1L 4 19 Row A Bit P0L 4 51 Row B Bit P0H 4 83 Row C Bit P1L 4 20 Row D Bit P1H 4 52 Row B Bit P0H 4 84 Row D ...

Страница 8: ...ector Power and CAN Pin Number Signal Description 1 GND Ground connection 2 24V Board power supply 3 CAN L CAN Bus Low signal 4 CAN H CAN Bus High signal X1 pinout description Plug type Manufacturer Weidmuller Model BLZF 3 50 04 180 ...

Страница 9: ...ddress is composed by 2 elements the module identification and the hardware address The module identification is set on firmware and cannot be changed The hardware address is selected by switches 3 to 8 being 3 the least significant bit LSB and 8 the most significant bit MSB ON 1 2 3 4 5 6 7 8 ON 1 OFF 0 LSB MSB Board Address SW1 behaviour Switch ID Description Definition of Behaviour SW2 BOOT0 Fa...

Страница 10: ...peration speed 50 250 kbps Ambient operating temperature 5 65 degC Operation specifications Switching specifications Property Min Typ Max Units Rated current 5 A Maximum switching voltage 250 VAC VDC Minimum switching voltage 5 VAC VDC Switching power 1250 VA Contact resistance 30 mOhm Operate time 5 10 ms Release time 3 8 ms Switching specifications ...

Страница 11: ...system maintenance on site Activate relays By clicking a relay in the panel the relay closes and its status in the panel is updated Reset Reset button will put all relays in Open status Config tags To operate with Phi6 driver each relay must be given a tag name By clicking this button the panel will change its background color from grey to yellow and tag name can be modified ...

Страница 12: ...ing com 22 06 2022 YAV904X8 12 LOW LEVEL CAN COMMANDS 13 ACCESSORIES Item Description PN ITA Module TriPaddle Signal Module 96 Position VP510108126 ITA Tripaddle pin TriPaddle Signal Contact 7 Amp 20 24 AWG 30μ Gold VP610110108 ...

Страница 13: ...ully to avoid damage To install the YAV904X8 simply insert the module on a VPC receiver vertical or horizontally according to the Receiver arrangement Once it is completely inserted fix YAV module with two 4 40 UNC screws on each side of connector Tight them using a 3 32 Allen wrench at full revolutions Torque should be 0 45Nm max Finally connect the X1 rear plug of CAN bus and power supply 24VDC ...

Отзывы: