15
Sensor name
Raw value
Dynamic range value
Scaled value
Lower calibration value
Upper calibration value
Graph bottom
value
Graph top
value
Current graph
value
Figure 16 – The Sensor Info Box
The upper and lower calibration values may be fine-tuned by adjusting the
minimum and maximum values of the dynamic range. These values are
automatically adjusted during auto calibration. Please note that the calibration
mode is automatically switched to manual calibration during fine-tuning.
The sensor info box has three levels of detail, depending on the pixel resolution
available to GloveManager. The highest level of detail is shown in Figure 16. As
the pixel resolution decreases, the second level of detail is switched to, as in
Figure 17. The value shown next to the sensor name is:
•
the current scaled value (when scaled graphs are visible)
•
the current raw value (when raw graphs are visible)
Figure 17 – The Second Level of Detail of the Sensor Info Box.
If the pixel resolution is decreased more, only the sensor name and current
graph value are shown.
Figure 18 – The Lowest Level of Detail of the Sensor Info Box.