Dual Injector Pro+ User Manual (Ver. 1-2017) 

 

 

 

 

 

 

 

     Page  6

4.2 Post DUAL INJECTOR PRO+ treatment advice

Recommended treatment FREQUENCY:

Initial phase for intense treatment:

Young skin should be 1 per week for 4 weeks; middle aged skin 1 per week for 6 weeks; mature skin 1 per 

week for 8 weeks.
Maintenance:

Young skin once every 4 - 6 weeks (up tp 8 weeks); middle aged skin once every 4 - 6 weeks (up to 3 

months); and mature skin once every 3 weeks (up to 5 months).

The following AFTERCARE instructions are advised:

12 hours following the treatment, do not expose treated area to direct heat including hot showers. 

Do not use a jacuzzi, steam room or sauna. Do not participate in activities that may cause excessive 

perspiration. 
Erythema can occur following treatment, but will resolve within a few hours.

5. Safety Warnings

Never operate this equipment on a person that has or suffers from the following medical conditions 

described below. (The salon or operator should consider having the client sign a medical history and 

consent form to the effect that he/she is free of any poor health conditions).

•  Heart Disease 

•  Heart Murmur or Irregular Heart Rate 

•  Has a Pacemaker or other type of heart rate balancer

•  Epilepsy 

•  Ulcers 

•  Disease of Stomach, Intestine, Liver, or Pancreas 

•  Breast Cancer

•  Undergoing treatment for any form of Cancer

•  Untreated hypertension

•  Migraines and headaches

•  Any serious illness or disease not listed above

Overly aggressive use of RF should not be used on sensitive areas such as eyelids.
The machine is intended for professional use and it can be used only by professionals who have proper 

training. The producer is not responsible for liabilities for damages caused by improper use of this 

machine.
Any damage to the cables could cause a risk of electric shock, also they may cause serious damage  to 

the machine and fire. Do not open the cover under threat of loss of warranty. Opening the cover may 

cause electric shock.
Do not modify nor repair the machine by yourself under threat of loss of warranty. Protect the machine 

from moisture, water and dust, and keep the machine away from electric heater and other sources of 

heat. Do not cover the ventilation holes.
The machine can not be used for purposes other than those described in this manual.
Do not modify or attempt to repair the machine, contact your dealer or distributor for repair or 

maintenance.

Содержание AESTHETECH DUAL INJECTOR PRO+

Страница 1: ... Radio Frequency Electroporation LED unit Please read and carefully follow the instructions in this manual for optimal and safe use 4T Medical LTD G12 Blenheim House Cambridge Innovation Park Denny End Road Waterbeach Cambridge CB25 9GL T 01223 440285 E info 4tmedical com www 4tmedical com ...

Страница 2: ...tions 3 2 Illustration of DUAL INJECTOR PRO 4 2 1 DUAL INJECTOR PRO Control Panel 4 3 Preparation before treatment 5 4 How to use DUAL INJECTOR PRO 5 4 1 Cleaning and maintenance 5 4 2 Post DUAL INJECTOR PRO treatment advice 6 5 Safety Warnings 6 6 Warranty and Service 7 7 Troubleshooting 7 8 Technical specifications 7 8 1 Marking description 7 8 2 EUROPEAN REGULATIONS 7 ...

Страница 3: ...l rejuvenation of skin health No recovery or down time No anaesthetic requirement Reduction of minor to moderate early ageing fine lines Stimulation of fibroblasts for collagen production Hyperpigmentation reduction Enhanced penetration of active ingredients 1 2 Treatable Conditions Conditions that can be treated with DUAL INJECTOR PRO Sun induced pigmentation melasma age spots Ageing and sagging ...

Страница 4: ...Injector Pro User Manual Ver 1 2017 Page 4 2 Illustration of DUAL INJECTOR PRO 2 1 DUAL INJECTOR PRO Control Panel TREATMENT HANDLE ELECTROPORATION LEVEL ON OFF RADIO FREQUENCY TIME LEVEL ON OFF LEVEL LEVEL ...

Страница 5: ...f the face 6 ELECTROPORATION Set timer to 5 minutes using Up Down arrows 7 Press silver dial down to turn on Electroporation The head of the probe appears BLUE 8 Use the silver dial to set the intensity Min Max according to the red light around the dial Start intensity half way Always check client comfort 9 Treat one side of the face for 5 minutes then repeat on opposite side of the face for a fur...

Страница 6: ...ons Heart Disease Heart Murmur or Irregular Heart Rate Has a Pacemaker or other type of heart rate balancer Epilepsy Ulcers Disease of Stomach Intestine Liver or Pancreas Breast Cancer Undergoing treatment for any form of Cancer Untreated hypertension Migraines and headaches Any serious illness or disease not listed above Overly aggressive use of RF should not be used on sensitive areas such as ey...

Страница 7: ...s in off position Turn on the on off button on the back of the machine System does not start Power disconnected Turn off the power Check that the power cable is plugged into electrical outlet and connected to the main units power inlet 8 Technical specifications Main Power 230V 50 Hz DC 12V Radio Frequency 500 kHz Red LED Electroporation 1 9 kHz Blue LED Max effect 30 W Size 220 x 100 x 200 mm W x...

Отзывы: