4T Medical AESTHETECH DUAL INJECTOR PRO+ Скачать руководство пользователя страница 1

Dual Injector Pro+ User Manual (Ver. 1-2017) 

 

 

 

 

 

 

 

     Page  1

User Manual

(ver. 1-2017)

DUAL INJECTOR PRO+

Radio Fre Electropo LED unit

Please read and carefully follow the instructions in this manual for optimal and safe use.

4T Medical LTD, G12 Blenheim House, Cambridge Innovation Park, Denny End Road, Waterbeach, Cambridge, CB25 9GL

T: 01223 440285    E: [email protected] 

   

www.4tmedical.com

Содержание AESTHETECH DUAL INJECTOR PRO+

Страница 1: ... Radio Frequency Electroporation LED unit Please read and carefully follow the instructions in this manual for optimal and safe use 4T Medical LTD G12 Blenheim House Cambridge Innovation Park Denny End Road Waterbeach Cambridge CB25 9GL T 01223 440285 E info 4tmedical com www 4tmedical com ...

Страница 2: ...tions 3 2 Illustration of DUAL INJECTOR PRO 4 2 1 DUAL INJECTOR PRO Control Panel 4 3 Preparation before treatment 5 4 How to use DUAL INJECTOR PRO 5 4 1 Cleaning and maintenance 5 4 2 Post DUAL INJECTOR PRO treatment advice 6 5 Safety Warnings 6 6 Warranty and Service 7 7 Troubleshooting 7 8 Technical specifications 7 8 1 Marking description 7 8 2 EUROPEAN REGULATIONS 7 ...

Страница 3: ...l rejuvenation of skin health No recovery or down time No anaesthetic requirement Reduction of minor to moderate early ageing fine lines Stimulation of fibroblasts for collagen production Hyperpigmentation reduction Enhanced penetration of active ingredients 1 2 Treatable Conditions Conditions that can be treated with DUAL INJECTOR PRO Sun induced pigmentation melasma age spots Ageing and sagging ...

Страница 4: ...Injector Pro User Manual Ver 1 2017 Page 4 2 Illustration of DUAL INJECTOR PRO 2 1 DUAL INJECTOR PRO Control Panel TREATMENT HANDLE ELECTROPORATION LEVEL ON OFF RADIO FREQUENCY TIME LEVEL ON OFF LEVEL LEVEL ...

Страница 5: ...f the face 6 ELECTROPORATION Set timer to 5 minutes using Up Down arrows 7 Press silver dial down to turn on Electroporation The head of the probe appears BLUE 8 Use the silver dial to set the intensity Min Max according to the red light around the dial Start intensity half way Always check client comfort 9 Treat one side of the face for 5 minutes then repeat on opposite side of the face for a fur...

Страница 6: ...ons Heart Disease Heart Murmur or Irregular Heart Rate Has a Pacemaker or other type of heart rate balancer Epilepsy Ulcers Disease of Stomach Intestine Liver or Pancreas Breast Cancer Undergoing treatment for any form of Cancer Untreated hypertension Migraines and headaches Any serious illness or disease not listed above Overly aggressive use of RF should not be used on sensitive areas such as ey...

Страница 7: ...s in off position Turn on the on off button on the back of the machine System does not start Power disconnected Turn off the power Check that the power cable is plugged into electrical outlet and connected to the main units power inlet 8 Technical specifications Main Power 230V 50 Hz DC 12V Radio Frequency 500 kHz Red LED Electroporation 1 9 kHz Blue LED Max effect 30 W Size 220 x 100 x 200 mm W x...