background image

1   Spa operation

1.1 

Hydro-massage Pump

This Spa has 1 pump (two speed) enabling you to select the preferred intensity of hydro-massage. This pump is connected and operated through
the display (Fig.1). 

• Press on the buttons          to activate the pump at low speed. 
• Press the same button a second time to turn to high speed.
• Pressing the same button a third time turns the Pump off. 

A built-in timer automatically turns off the Pump after 20 minutes. 

For spa’s without circulation pumps only: if the pump is running automatically at low speed or remains running on low speed then the heating and/or fi ltration 
cycle is operating and the pump will continue until the water has reached the desired temperature and/or the fi lter cycle is fi nished.

1.2 

Lighting

• Press the         to turn light on.
• Press a second time (within 4 seconds) to switch to a different color.
• Press a third time (within 4 seconds) to continue changing the color or alter the lighting sequence.

A built-in timer automatically turns off the light after 2 hours.

1.3 

Blower (where fi tted)

When your spa has a blower you can start it the following way:

• Press the         to turn blower on.
• Press a second time to stop the blower.

A built-in timer automatically turns off the Blower after 20 minutes.

1   Spa Operation

4

Содержание Anna 33

Страница 1: ...USER MANUAL EasyMini control box Spa models Savannah Lisa 23 and Augusta 20 Anna 33 With and without circulation pump ...

Страница 2: ...ridges 5 2 2 Filtering 5 2 3 Water Temperature 6 2 4 Economy Mode 7 3 OTHER 7 3 1 Display Lock 7 3 2 Display Rotation 8 3 3 Stand By Function 8 3 4 Clock Function 8 4 HYDRO MASSAGE 9 4 1 Regulating the Jet power 9 4 2 Jets 9 5 EMPTYING THE SPA 9 6 WATERTREATMENT 10 6 1 Preparations 10 6 2 3 step Water treatment 10 7 IMPORTANT THINGS TO KNOW DO TO MAINTAIN YOUR SPA 11 8 SERVICE 12 Contents ...

Страница 3: ... Operating spa display The Spa is operated through the main display enabling you to activate the Spa pump light and blower where fitted and control the settings filtration temperature time Icon Solid Blinking Pump 1 active at high speed Pump 1 active at low speed Blower active Light on Display showing the desired temperature Filter or Purge function active Filter or Purge function in stand by Heater...

Страница 4: ...ow speed or remains running on low speed then the heating and or filtration cycle is operating and the pump will continue until the water has reached the desired temperature and or the filter cycle is finished 1 2 Lighting Press the to turn light on Press a second time within 4 seconds to switch to a different color Press a third time within 4 seconds to continue changing the color or alter the light...

Страница 5: ...lease ask your dealer and check page 10 2 1 Filter Cartridges The Spa is equipped with 1 or 2 cartridge water filters to filter small impurities from the water As a result the filters may become clogged resulting In reduced water flow It is important to maintain a clean unobstructed filtration system Clean the filter cartridge every week by rinsing it with a powerful water jet a garden hose not a pressu...

Страница 6: ...ter temperature to the desired level The newly selected water temperature will be shown on the display for five seconds confirming the new settings display shows After 5 seconds the display will again show the current temperature The water will be re heated when the temperature has dropped 0 5 degrees Celsius The water temperature can be set at a value between 15 and 40 C be shown on the display for...

Страница 7: ...an be a useful safety measure when the Spa is often used by children There are two settings possible Partial LOCK P buttons operating pumps and the light can be operated Full LOCK F none of the buttons will function Press and hold the button for 3 seconds the partial display lock LOCK P is activated Press and hold the button for 6 seconds all buttons are disabled LOCK F Press and hold the button a...

Страница 8: ...n your display and the elapsing time will be in minutes The STAND BY function locks the filtering purging cycles which are programmed and carried out every 40 min after the end of the stand by function This function can be terminated by pressing the key LIGHT for 5 seconds or available time has elapsed 60 minutes 3 4 Clock Function This function is controlled by the user by the key which helps you ...

Страница 9: ...e venturi system The air supply is regulated using one of the venturi air valves Turn the valve to the left to open the air supply or to the right to close the air supply Each seat combination has its own venturi air valve You will only see an effect when the pump is operating at high speed The air valves are the small controllers found on the top edge of the spa To regulate the water distribution...

Страница 10: ...l your spa use only regular tap water As soon as the spa is filled begin water treatment The filtration mechanism has to be on continuously which requires constant current to be available 6 2 3 step Water treatment 1 Test the pH value of the water and adjust if necessary Keep the pH between 7 2 and 7 6 At this pH value disinfecting products will work best The total alkaline value should be kept betw...

Страница 11: ...n hose not a high pressure washer Once every 2 or 3 months clean and grease the diverters to prevent dehydration and lime calcification When your diverters are turning smoothly 7 Important things to know do to maintain your spa 11 To test for these values use a reliable testing kit and record the values in a log book This way you can maintain an overview of the manner in which the water is treated ...

Страница 12: ...ur spa resulting in a specific code on your display please check the table below The description after the display code explains what it means Problem and provides advice on how to solve it Action If the problem persists after following recommended actions please get in contact with your authorized 4SeasonsSpa dealer Your closest 4SeasonsSpa dealer can be found at www 4Seasonsspa com stores Display...