background image

 

Quick Installation Guide 

EAP750 Enterprise Access Point 

ENGLISH 

Copyright © 4IPNET, INC. All rights reserved.   

iii

CE CAUTION 

 

Declaration of Conformity with Regard to the 1999/5/EC (R&TTE Directive) for   

European Community, Switzerland, Norway, Iceland, and Liechtenstein   

Model: EAP750   

For 2.4 GHz radios, the device has been tested and passed the requirements of the following standards, and 

hence fulfills the EMC and safety requirements of R&TTE Directive within the CE marking requirement. 

• Radio: EN 300.328

:

 

• EMC: EN 301.489-1, EN 301.489-17,   

• EMC: EN 55022

 

Class B, EN 55024

:

+ A1 + A2

 

including the followings: 

      EN 61000-3-2, EN 61000-3-3. 

      EN 61000-4-2, EN 61000-4-3, EN 61000-4-4,   

      EN 61000-4-5, EN 61000-4-6, EN 61000-4-11 

• Safety: EN 60950-1 + A11, 

 

Caution:

   

 

This declaration is only valid for configurations (combinations of software, firmware, and hardware) 

provided and supported by 4ipnet Inc. The use of software or firmware not provided and supported by 

4ipnet Inc. may result in the equipment no longer being compliant with the regulatory requirements.   

European standards dictate maximum radiated transmit power of 100mW EIRP and frequency range 

2.400-2.4835 GHz. This equipment is intended to be used in all EU and EFTA countries. Outdoor use may be 

restricted to certain frequencies and/or may require a license for operation. Contact your local regulatory 

authority for compliance. 

 

Taiwan NCC Statement

 

 

 

根據

NCC

低功率電波輻射性電機管理辦法

 

規定

:

 

第十二條

 

經型式認證合格之低功率射頻電機,非經許可,公司、商號或使用者均不得擅自變更頻率、加大功率或

變更原設計之特性及功能。

 

第十四條

 

 

 

低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經發現有干擾現象時應立即停用,並改善至

無干擾時方得繼續使用。

 

前項合法通信,指依電信法規定作業之無線電通信。

 

低功率射頻電機須忍受合法通信或工業、科學及醫療用電波輻射性電機設備之擾。

 

 

 

Содержание EAP750 V1.00

Страница 1: ...EAP750 V1 00 Enterprise Access Point ...

Страница 2: ... not copy reproduce distribute publish display perform or modify any part of this publication in any form or by any means without prior written permission from 4IPNET INC You may not alter or remove any copyright or other notice from copies of the content All other brand and product names are claimed or registered marks of their respective companies or organizations All rights reserved To download...

Страница 3: ...n If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit diff...

Страница 4: ... 4 11 Safety EN 60950 1 A11 Caution This declaration is only valid for configurations combinations of software firmware and hardware provided and supported by 4ipnet Inc The use of software or firmware not provided and supported by 4ipnet Inc may result in the equipment no longer being compliant with the regulatory requirements European standards dictate maximum radiated transmit power of 100mW EI...

Страница 5: ...to bridge wireless links of multiple EAP750s for forming a wider wireless network coverage EAP750 also features multiple ESSIDs with VLAN tags and multiple Virtual APs great for enterprise applications such as separating traffic from different departments using different ESSIDs The PoE Uplink port is able to receive power from Power over Ethernet PoE sourcing devices This Quick Installation Guide ...

Страница 6: ...et to factory default 3 WES Button WDS Easy Setup Press the button to build up a WDS link with another peer 4 LED Indicators 6 LED lights are available What the numbers stand for is listed at the bottom of the panel 5 Uplink PoE Port Offers uplink connection This port can be used to connect to a controller gateway or directly to the Internet PoE is also supported 6 LAN 1 2 Ports Attach Ethernet ca...

Страница 7: ...ne end of the Ethernet cable to the Uplink port of EAP750 and the other end of the cable to a switch a router or a hub EAP750 is then connected to your existing wired LAN network There are two ways to supply power over to EAP750 3 Connect the DC power adapter to the EAP750 power socket EAP750 Uplink port is capable of receiving DC currents Connect an IEEE 802 3af compliant PSE device e g a PoE swi...

Страница 8: ...bnet Mask 255 255 255 0 Steps 1 To access the Web Management Interface connect the administrator PC to the Uplink port of EAP750 via an Ethernet cable Then set a static IP address on the same subnet mask as EAP750 in TCP IP of your PC such as the following example IP Address 192 168 1 100 Subnet Mask 255 255 255 0 2 Launch the web browser on your PC by entering the IP address of EAP750 https 192 1...

Страница 9: ...age 4 After a successful login to EAP750 a System Overview page of the Web Management Interface will appear as depicted below The Web Management Interface System Overview Page 5 To logout simply click on the Logout button at the upper right hand corner of the interface to return to the Administrator Login Page Click OK to logout ...

Страница 10: ...n Settings Step 1 Change Administrator s Password Change Password Page Click on the Utilities icon on the main menu and select the Change Password tab Enter the old password and then a new password with a length of up to 32 characters and retype it in the Re enter New Password field Click SAVE to save the changes ...

Страница 11: ...ect your preferred Band and Channel for you wireless connection For example select 802 11g 802 11n for the band and 6 for the channel Note Admin should be aware of Dynamic Frequency Selection DFS mandated on some channels of the 5GHz band When an EAP750 detects interference this mechanism will limit the ability to broadcast the SSID on one of the channels listed below 1 Country Code 840 US DFS Cha...

Страница 12: ...hown EAP750 supports up to 8 virtual APs VAPs per RF Card Configure VAP profile settings a Select the VAP Configuration tab to configure the settings of the desired VAP b Enable a specific VAP from the drop down menu of Profile Name and configure related settings below Check VAP status After finishing VAP configuration the status of enabled Virtual APs shall be reflected on the VAP Overview page ...

Страница 13: ...Quick Installation Guide EAP750 Enterprise Access Point ENGLISH Copyright 4IPNET INC All rights reserved 9 Virtual AP Overview Page ...

Страница 14: ... tab Choose WDS as the Repeater Type Choose the desired WDS profile a Enable WDS b Enter the MAC Address peer AP and then Click SAVE If you are using another EAP750 as the peer AP simply repeat the above mentioned steps to configure another peer AP s Note On each and every configuration page you may click SAVE to save the changes of your configured settings but you must reboot the system for the c...

Страница 15: ...se remember to change the IP Address of your PC Connection Properties back to its original settings in order to ensure that your PC functions properly in its real network environments It is strongly recommended to make a backup copy of your configuration settings For further configuration and backup information please refer to the User s Manual P N V10020120713 ...

Отзывы: