Use a straight twisted pair CAT5 (or higher) cable with RJ45 plugs (included with DCA 2.500 amplifier). Any
standard Ethernet patch cable may be used.
NOTE: Mind the connection order of the DCA2.500 amplifiers on the AMP LINK! The connection order
determines the local AMP LINK address of the amplifier, according to software configuration settings for
Impact amplifiers. Settings and commands will be applied by the controller according to that addressing.
Use a straight twisted pair CAT5 (or higher) cable with RJ45 plugs (included with DCA 2.500 amplifier). Any
standard Ethernet patch cable may be used.
NOTE:
The AMP LINK is a monitored main system bus providing audio and surveillance data.
The
AMP LINK
does not support redundancy
and therefore, in EN54 compliant applications, the AMP LINK cable must be
located entirely inside the system cabinet. No part of it may be exposed to external access.