4E-FMTC installation and user guide 

Author: 

DD 

 

 

 

Page 16 of 17 

  

 

6.

 

Technical specifications 

 

 

 

4E-FMTC 

 

Number of zones 

max. 255 zones (global network access) 

Controls and indications 

Mandatory LEDs: power, fault, evac, busy, fireman PTT button; 

RGB touchscreen witch user-configurable buttons: zone / group selection, 

sources, events, fault/event logging 

Microphone (dual) 

 

 

General paging 

Condenser, gooseneck 

 

Emergency 

MEMS transducer, handheld, monitored 

Power consumption 

 

 

24V (L-Net) 

max. 180mA 

Audio 

 

 

Frequency response 

100 Hz – 12 kHz 

 

Digital audio format 

24 kHz sampling, ADPCM compressed 

 

Audio processing 

Fixed BP filter, fixed dynamics compression 

Local network interface 

 

 

Architecture 

Master-slave, up to 16 slave devices per C500 main unit 

 

Connection 

RJ-45, powered daisy chain, digital audio & control data 

 

Cabling 

X-over FTP CAT5e (or higher) 

 

Current rating via single link 

max. 500 mA (up to 8 slave devices) via L-Net port,  

 

Max. length of L-Net link 

250 m 

Mechanical 

 

 

Base dimensions (HxWxL) 

6 x 26 x 21 cm 

 

Gooseneck mic length 

31.5 cm 

 

Weight 

1850 g 

 

Housing material 

Steel / ABS 

 

IP rating 

IP 30 

 

Mounting 

Desktop wedge / wall-mounted (incl. wall bracket) 

Operating conditions 

 

 

Temperature 

10–40°C 

 

Relative humidity 

max. 90% (non condensing) 

Storage temperature 

-40–70°C 

Содержание 4E-FMTC

Страница 1: ...ion System It explains how the 4E FMTC should be installed and configured The installation instructions are addressed to trained technical personnel such as installers service technicians and commissi...

Страница 2: ...t 3 3 Configuration settings 4 4 Hardware installation and settings 5 L Net 5 4 1 1 Network ports 5 4 1 2 Redundant link 6 4 1 3 Network cabling 7 Device ID 8 5 Front Panel 9 LED indicators 10 5 1 1 P...

Страница 3: ...e paging and emergency evacuation management is necessary 4E FMTC includes fault monitoring and EVAC functionality thus is suitable as an emergency microphone 2 Where do I start First make sure that y...

Страница 4: ...ilable for audio routing BGM inputs general purpose messages microphone volume level individual for both gooseneck and fireman s mic TALK button mode PTT toggle etc The configuration file should be pr...

Страница 5: ...m 8 of stations per L Net port A maximum 16 of stations per single C500 main unit total sum of all 3 L net ports The microphone station may be also daisy chained together with other L Net devices Comp...

Страница 6: ...ith other L Net devices NOTE The device is equipped with a power link jumper which by default is in the ON position pass through power over L Net In order to create a redundant link the jumper must be...

Страница 7: ...least FTP NOTE If you use a straight cable the device will power up but the Tx Rx data terminals will not be properly connected This will result in a communication fault between the L Net device and...

Страница 8: ...set the Device ID you must access the rotary switches on the back side of the unit 1 Remove the steel plate covering back of the station 2 Identify the high significant and low significant rotary swi...

Страница 9: ...eck microphone Emergency section with fireman microphone The emergency section is closed behind a transparent door for access level protection While the door remains closed the 4E FMTC remains in gene...

Страница 10: ...east one device in the system is reporting a fault Continuous when a local station fault is detected o Microphone short or open circuit o PTT button short or open circuit o Network link fault Blinking...

Страница 11: ...reen If there are more than 6 zones accessible use the scroll arrow button to scroll through pages with zone selection 5 2 1 2 Source selection Next on the right section of the screen select the sourc...

Страница 12: ...nel ALL CALL NOTE In paging mode you can use only gooseneck microphone 5 2 1 4 Stop message BGM Select zones where the message BGM audio signal is being transmitted and press STOP This will reset thes...

Страница 13: ...group of zones For more information about programming events please look in the user manual of the 4EVAC Manager where all configuration settings are explained 5 2 3 LOG tab Under the LOG tab you will...

Страница 14: ...nes accessible than the screen can display at one time use the scroll arrow button to scroll through pages with zone selection 5 3 1 2 Emergency Message selection Next on the left bottom section of th...

Страница 15: ...L NOTE In emergency mode you can only use the fireman s microphone 5 3 1 4 Stop emergency message Select the zones where the message audio signal is being transmitted and press STOP This will reset th...

Страница 16: ...ncy response 100 Hz 12 kHz Digital audio format 24 kHz sampling ADPCM compressed Audio processing Fixed BP filter fixed dynamics compression Local network interface Architecture Master slave up to 16...

Страница 17: ...651BC Berkel Rodenrijs 4E FMTC installation and user guide Author DD Page 17 of 17 M A D E I N T H E N E T H E R L A N D S 4EVAC is a trade name of Hacousto Holland bv Industrieweg 87 2651BC Berkel Ro...

Отзывы: