Hardware installation and settings 

 

L-Net 

4E-CMP is a remote station connected to the L-Net port of the C500 main unit. Multiple 4E-CMP stations 

may be used in the same L-Net, with the following limitations: 

 

A maximum of 8 stations per L-Net port 

 

A maximum of 16 stations per single C500 main unit (total sum of all 3 L-net ports) 

The microphone station may also be daisy-chained together with other L-Net devices 
 

 

Compact 500 L-Net (local network) 

4.1.1.

 

Network ports 

4E-CMP offers 2 L-Net ports (RJ-45) for network connections to the C500 main unit and distributed parts 

of the 4EVAC Voice Evacuation System. Both L-Net ports are equal, therefore it makes no difference which 

port is connected to which side of the L-Net daisy-chain. 
 

 

L-Net ports on the back side of 4E-CMP 

Содержание 4E-CMP

Страница 1: ...xplains how the 4E CMP should be installed and configured Installation instructions are addressed to trained technical personnel such as installers service technicians and commissioning engineers User...

Страница 2: ...t is the 4E CMP 3 2 Where do I start 3 3 Configuration settings 4 4 Hardware installation and settings 5 L Net 5 4 1 1 Network ports 5 4 1 2 Network cabling 6 Device ID 7 5 Front Panel 8 LED indicator...

Страница 3: ...ke sure that you are officially allowed to access the hardware of Compact 500 system devices This is usually the case if you are an authorized representative of 4EVAC you have been trained by 4EVAC or...

Страница 4: ...as zone selection buttons microphone volume level TALK button mode PTT toggle etc The configuration file should be prepared in the C500 Manager C500 Manager is GUI software running on Windows OS More...

Страница 5: ...tations per L Net port A maximum of 16 stations per single C500 main unit total sum of all 3 L net ports The microphone station may also be daisy chained together with other L Net devices Compact 500...

Страница 6: ...ired at least FTP NOTE If you use a straight cable the device will power up but the Tx Rx data terminals will not be properly connected This will result in a communication fault between the L Net devi...

Страница 7: ...check or set the Device ID you must access the rotary switches on the back side of the unit 1 Remove the steel plate covering back of the station 2 Identify the high significant and low significant ro...

Страница 8: ...l but is in SILENCE mode triggered by the SILENCE input or manual SILENCE button Blinking slow indicates that the zone is currently transmitting an audio signal except BGM from another device Blinking...

Страница 9: ...iguration settings 5 2 2 TALK This button starts voice transmission to selected zones Depending on configuration settings the TALK button works in one of two ways PTT push to talk Toggle Zone labels T...

Страница 10: ...mpling ADPCM compressed Audio processing Fixed BP filter fixed dynamics compression Local network interface Architecture Master slave up to 16 slave devices per C500 main unit Connection RJ 45 powered...

Страница 11: ...651BC Berkel Rodenrijs 4E CMP installation and user guide Author DD Page 11 of 11 M A D E I N T H E N E T H E R L A N D S 4EVAC is a trade name of Hacousto Holland bv Industrieweg 87 2651BC Berkel Rod...

Отзывы: