background image

 

 

INDUSTRIAL VACUUM CLEANER 

 
EN

 

 

 

 

TECHNICAL DATA 

Operating voltage and frequency 

220-240 VAC - 50/60 Hz 

Power 

1600 W

 

Power at socket (max) 

2000 W, Сlass 1

 

Total power (max) 

3600 W

 

Air capacity 

119 m

3

/h 

Vacuum level 

180 hPa 

Weight Brutto/Netto  

15 / 12 kg 

Dimensions 

600 x 375 x 575 mm 

Class of protection 

IPX 4 

Noise level EN 60704-3 

73 dB (A) 

Container capacity 

8 L 

Inlet air pressure 

6 bar 

Max compressed air flow 

1400 L/min 

 

GENERAL EQUIMPENT SAFETY WARNINGS 

  

WARNING

! Read all safety warnings and all instructions. Failure to follow the warnings and instructions may result in 

electric shock, fire and/or serious injury. Save all warnings and instructions for future reference. 
The term “equipment” on the warnings refers to your mains-operated (corded) Mobile Vacuum Cleaner. 

1)

 

WORK AREA SAFETY 
a)

 

Keep work area clean and well lit. Cluttered or dark areas invite accidents. 

b)

 

Do  not  operate  equipment  in  explosive  atmospheres,  such  as  in  the  presence  of  flammable  liquids,  gases  or  dust. 

Equipment creates sparks which may ignite the dust or fumes. 

c)

 

Keep children and bystanders away while operating equipment. Distractions can cause you to lose control. 

2)

 

ELECTRICAL SAFETY 
a)

 

Equipment  plugs  must  match  the  outlet.  Never  modify  the  plug  in  any  way.  Do  not  use  any  adapter  plugs  with  earthed 

(grounded) equipment. Unmodified plugs and matching outlets will reduce risk of electric shock. 

b)

 

Avoid  body  contact  with  earthed  or  grounded  surfaces,  such  as  pipes,  radiators,  ranges  and  refrigerators.  There  is  an 

increased risk of electric shock if your body is earthed or grounded. 

c)

 

Do not expose equipment to rain or wet conditions. Water entering equipment will increase the risk of electric shock. 

d)

 

Do not abuse the cord. Never use the cord for carrying, pulling or unplugging the equipment. Keep cord away from heat, 

oil, sharp edges or moving parts. Damaged or entangled cords increase the risk of electric shock. 

e)

 

When operating a equipment outdoors, use an extension cord suitable for outdoor use. Use of a cord suitable for outdoor 

use reduces the risk of electric shock. 

f)

 

If operating equipment in a damp location is unavoidable, use a residual current device (RCD) protected supply. Use of an 

RCD reduces the risk of electric shock. 

3)

 

PERSONAL SAFETY 
a)

 

Stay alert, watch what you are doing and use common sense when operating equipment. Do not use equipment while you 
are tired or under the influence of drugs, alcohol or medication. A moment of inattention while operating equipment may 
result in serious personal injury. 

b)

 

Use personal protective equipment. Always wear eye protection. Protective equipment such as dust mask, non-skid safety 
shoes, hard hat, or hearing protection used for appropriate conditions will reduce personal injuries. 

c)

 

Prevent  unintentional  starting.  Ensure  the  switch  is  in  the  off-position  before  connecting  to  power  source,  picking  up  or 

carrying the equipment. Carrying equipment with your finger on the switch or energising equipment that have the switch 
on invites accidents. 

d)

 

Remove any adjusting key or wrench before turning the equipment on. A wrench or a key left attached to a rotating part of 

the power tool may result in personal injury. 

e)

 

Do not overreach. Keep proper footing and balance at all times. This enables better control of the power tool in unexpected 

situations. 

f)

 

Dress  properly.  Do  not  wear  loose  clothing  or  jewellery.  Keep  your  hair,  clothing  and  gloves  away  from  moving  parts. 

PICTOGRAMS 

 

Read the following instruction 
first before operating the product

 

 

Important safety indications

 

 

Caution! This appliance contains 
dust hazardous to health. 
Emptying and manteinance 
operations, including removal of 
the dust collection means, must 
be carried out only by authorized 
personnel wearing suitable 
personal protections. Do not 
operate without the full filtration 
system fitted. 

Содержание 9500

Страница 1: ...ff 4 Front hose nozzle 5 Handle 6 Power cord 7 Head lockers 8 Water tank 9 Pneumatic tool connection 10 Electric tool socket 11 Speed control 12 Rubber cap 13 Castor wheels with lock 14 Operating air...

Страница 2: ...INDUSTRIAL VACUUM CLEANER EN 2...

Страница 3: ...arp edges or moving parts Damaged or entangled cords increase the risk of electric shock e When operating a equipment outdoors use an extension cord suitable for outdoor use Use of a cord suitable for...

Страница 4: ...hazardous situation 5 SERVICE a Have your equipment serviced by a qualified repair person using only identical replacement parts This will ensure that the safety of the equipment is maintained INSPEC...

Страница 5: ...d detach the floor brush hose by turning it counter clockwise with the other hand Installation of the front wheels 5 Remove the upper part of the vacuum cleaner body Insert the steering axles of the t...

Страница 6: ...rt automatically After operating in hazardous dust contaminated environment all appliance parts must be considered as contaminated before handling the appliance out the 1 contaminated area or servicin...

Страница 7: ...top part of the vacuum cleaner Use the water level to control the amount of water at the bottom part of the vacuum cleaner Drain the excess amount of water if necessary Removal of dust from the dust...

Страница 8: ...ised service centre Tools do not start 3 way switch malfunction Contact an authorised service centre Insufficient Power for pneumatic tool Insufficient compressed air feeding Check air passage DISPOSA...

Отзывы: