14.

 

Maintenance Procedure 

 

DANGER:

 

EXPOSED  BUCKETS  AND  MOVING  PARTS  WILL  CAUSE  SERIOUS  INJURY  OR 

DEATH.  THE  OPERATOR  MUST  ALWAYS  LOCKOUT  POWER  BEFORE  REMOVING  COVER  OF 
THE  INSPECTION  DOOR  OF  THE  ELEVATOR  OR  PERFORMING  ANY  INSTALLATION  OR 
MAINTENANCE WORK. 
 

DANGER:

 

ALL ELECTRICAL POWER TO THE SYSTEM AND WIRING MUST BE ISOLATED PRIOR 

TO  STARTING  ANY  INSTALLATION  OR  MAINTENANCE  WORK.  WORKING  ON  OPEN  LIVE 
CIRCUITS IN ATEX ZONES IS PROHIBITED AND CAN LEAD TO AN EXPLOSION. 
 

Even though this system conforms to  ISO13849 Cat 2 PLd, 4B recommends that the system and all of its 
components are inspected at least once every 6 months. Below is the procedure that the end user must 
adhere to in order to maintain the system in a safe state. 
 

1)

 

Inspect  that  all  the  cabling  is  in  good  state  and  that  all  the  electrical  connections,  including  the 
terminal blocks in the junction boxes are secure and in good order 

2)

 

Make sure there is no water damage to the inside of the controller or any junction boxes used 

3)

 

Verify  that  the  TouchSwitch  sensors  are  operational  by  following  the  procedure  stated  in  9.6.2  
Testing and Commissioning 

4)

 

Verify that the speed sensor and the Whirligig are securely mounted on the shaft 

5)

 

Verify that the configuration switches of the W4005NV46AI /B controller are set as intended. Please 
refer to 10.13 - Settings Switches for more information. 

6)

 

Perform the W4005NV46AI /B controller simple test to check that all the LEDs are in working state. 
Please refer to 10.16.1 - Simple Test  for the explanation of this procedure. 

7)

 

Perform the W4005NV46AI /B controller extended test while elevator is running to verify that the 
W4005NV46AI /B can stop the elevator. This is needed to make sure that the control wiring is correct 
and  has  not  been  modified  since  the  last  test.  Please  refer  to  10.16.2  -  Extended  Test  for  the 
explanation of this procedure. 

 
IF  THE  SYSTEM  DOES  NOT  ALARM  AND  SHUTDOWN  AS  REQUIRED,  THEN  REMOVE  THE 
MACHINE FROM SERVICE UNTIL THE PROBLEM HAS BEEN DIAGNOSED AND CORRECTED. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание W4005V46-SYS/B Series

Страница 1: ...6 SYSx B B HLER Elevator Monitoring System OPERATION MANUAL MODELS W4005V46 SYS1 B W4005V46 SYS2 B Hardware Version R4 Software Main Processor 4 2 x Ethernet Processor 3 1 x www go4b com INSTALLATION...

Страница 2: ...AND P300V34AI B PROXIMITY SPEED SENSOR AND BRACKET INSTALLATION 15 8 3 ADB910V3AI B ADJUSTABLE DEPTH BEARING TEMPERATURE SENSOR 16 8 4 W4005NV46AI B W400 SERIES ELEVATOR CONTROLLER 17 9 ELECTRICAL INS...

Страница 3: ...020 Page 3 of 48 12 19 ETHERNET DATA ALLOCATION 34 13 TROUBLESHOOTING GUIDE 40 14 MAINTENANCE PROCEDURE 41 15 COMMISSIONING 42 16 SYSTEM BREAKDOWN PROCEDURE 42 17 MANUFACTURER INFORMATION 42 17 20 MAN...

Страница 4: ...E CONTROLLER AND THE ONE STATED ON THE FRONT OF THIS MANUAL MATCH MAKE SURE THE LATEST MANUAL FOR THE VERSION OF THE CONTROLLER IS OBTAINED ONLINE THE CONTROLLER VERSION INFORMATION CAN BE FOUND ON TH...

Страница 5: ...0231X Ex II 1D Ex ta IIIC T125 C Da IP65 Tamb 40 C to 60 C IECEx BAS 09 0111X Ex ta IIIC T125 C Da IP65 Tamb 40 C to 60 C NEPSI Ex GYJ16 1484X Ex tD A20 IP65 T125 C Ex ta IIIC T125 C Da X P300V34AI Ba...

Страница 6: ...Code Equipment Description Manufactured By Certificate No s 1 W4005NV46A W400 Elite 24V Controller Don Electronics Ltd DE COSC 101214 4 TS1V4AI Cable Entry TouchSwitch 24V Don Electronics Ltd IECEx BA...

Страница 7: ...ent Description Manufactured By Certificate No s 1 W4005NV46AI W400 Elite 24V Controller Don Electronics Ltd DE COSC 101214 4 TS1V4AI Cable Entry TouchSwitch 24V Don Electronics Ltd IECEx BAS13 0116X...

Страница 8: ...er Seal W400 BSA KIT B 1 4 x 1 8 Female to M6 Male Thread Adapters 4 x M6 Seal tights 2 x 1 8 Rp Female to 1 4 Rc Male Thread Adapters Table 3 System Components NB This item is only included in the W4...

Страница 9: ...the complete assembly either bolts to the machines shaft through a M12 tapped hole or is connected magnetically using 4B s patented Mag Con adaptor not included in the System kit Shaft or machine vibr...

Страница 10: ...troller Specifications 7 3 1 W4005NV46AI B Controller Fuses The W400 series controller has three replaceable fuses Please use the information below when ordering new fuses Fuse Reference Fuse Value Fu...

Страница 11: ...tions 7 6 WG4A BR B Whirligig Speed Sensor Mounting Whirligig Specifications Shaft Material Stainless Steel Body Material Polypropylene Bearing Type Sealed Stainless Steel Mounting Thread Size M12 Max...

Страница 12: ...d on a flat surface preferably with the cable entrance between the 3 to 9 o clock Figure 2 TouchSwitch Mounting Hole Drill The TouchSwitch can be mounted using one of the following three methods a Dri...

Страница 13: ...y to mount TouchSwitches so they are accessible from the head section walkway Be sure to mount TouchSwitches straight across from one another For typical mounting positions on a bucket elevator see Fi...

Страница 14: ...installed above the head shaft between the 9 o clock and 3 o clock position and as close to the 3 o clock as possible Note mount pair of TouchSwitches directly across from each other on right and lef...

Страница 15: ...suitable thread locking adhesive Loctite or similar Option 2 Use Mag Con magnetic connector Thread the Mag Con onto the Whirligig using a suitable thread locking adhesive Loctite or similar and attach...

Страница 16: ...earing sensor b Drill out and tap to 1 8 Rp BSPT x 6mm deep if needed c Slacken the olive nut and remove the sensor probe d Screw the sensor body into the new tapped hole in the bearing housing e Re i...

Страница 17: ...wiring must be carried out in accordance with relevant codes of practice and or instructions IEC 60079 14 IEC 60079 10 e The electronics inside the enclosure should not be modified No new components c...

Страница 18: ...onnected to the sensor contains the following 22 AWG wires Wire Color Function Red 24VDC Black 0VDC Green PE Power Earth White Relay Common Connection Blue Relay Contact N O Sensor Output to Controlle...

Страница 19: ...y and indicate the OK state by a lit up LED see Figure 8 NOTE TouchSwitchTM is delivered factory pre calibrated and no sensitivity adjustment is possible The sensor is calibrated to switch to the alar...

Страница 20: ...signal is visible to the operators at least annually The test procedure is given below 1 Observe that the red output LED on the sensor housing see Figure 8 is ON and the belt or pulley are not touchi...

Страница 21: ...ATOR MONITORING SYSTEM R9 6 22 May 2020 Page 21 of 48 9 7 P300V34AI B Proximity Speed Sensor Figure 11 Speed Sensor Wiring Diagram 9 8 ADB910V3AI B Adjustable Depth Bearing Temperature Sensor Figure 1...

Страница 22: ...4B W4005 B HLER ELEVATOR MONITORING SYSTEM R9 6 22 May 2020 Page 22 of 48 9 9 W4005NV46AI B W400 Elevator Controller 9 9 1 Overall System Wiring Schematics Figure 13 Overall System Wiring Diagram...

Страница 23: ...4B W4005 B HLER ELEVATOR MONITORING SYSTEM R9 6 22 May 2020 Page 23 of 48 9 9 2 Motor Start Stop Circuit Wiring Diagram 24VDC Power Figure 14 Motor Start Stop circuit wiring 24VDC Power...

Страница 24: ...4B W4005 B HLER ELEVATOR MONITORING SYSTEM R9 6 22 May 2020 Page 24 of 48 9 9 3 Motor Start Stop Circuit Wiring Diagram 100 240VAC Power Figure 15 Motor Start Stop circuit wiring 100 240VAC Power...

Страница 25: ...er than this will damage this circuit and should not be used Note Please see section 7 3 W4005NV46AI B W400 Series Elevator Controller for information on the relays Voltage and Current ratings Note Al...

Страница 26: ...splays the status of 4 bearing temperatures OFF Sensor OK AMBER Alarm LED Misalignment Indicators Displays the status of Top Bottom misalignment sensors OFF Sensor OK RED Alarm LED ALARM STOP Displays...

Страница 27: ...ose after the controller fault was reset TEST Button Short Press Simple Controller Test All LEDs blink once Two Short Presses Full System Test Must press second time within 1 second of the first press...

Страница 28: ...he switch states during power up If any changes to the settings are needed then the unit must be powered down the switch states changed and then the W4005NV46AI B can be powered up again and the new s...

Страница 29: ...red for the user to install two P300 sensors The W4005NV46AI B will be calibrated to a ratio between the bottom and top shaft speeds The running speed of the elevator can vary since the W4005NV46AI B...

Страница 30: ...se b Operate the START button on the motor starter This provides a motor run signal to the W4005NV46AI B terminal 16 which will cause the Stop relay to be energised and allow the machine to start The...

Страница 31: ...y is used for speed monitoring During this start up delay the speed is not monitored Additionally elevator Jam Block detection is implemented in the W4005NV46AI B controller If after the delays specif...

Страница 32: ...wice in quick succession Make sure to press and release the second time while the LEDs are lit from the first press i e when the simple test is running All the LEDs will toggle after which the Alarm F...

Страница 33: ...em is resolved It is prohibited to open the lid of the W4005NV46AI B controller or any junction boxes used in wiring of the system when electrical power is applied Please isolate the power before open...

Страница 34: ...Byte Offset System Status 1 System State 2 0 2 State Time 0 1s 2 2 3 Flags 2 4 Alarm 4 Shutdown Cause 2 6 5 Time to Shutdown 0 1s 2 8 6 Muted Not Active 2 10 Speed Section 7 Status 2 12 8 Nominal Spe...

Страница 35: ...r Occurred Contact the manufacturer 7 INVALID Invalid State System Error Occurred Contact the manufacturer 8 INVALID Invalid State System Error Occurred Contact the manufacturer 9 INVALID Invalid Stat...

Страница 36: ...Shutdown Source This field informs the user of what the shutdown source currently is This value is latched after an alarm shutdown until the elevator is restarted The list of shutdown sources is given...

Страница 37: ...This field returns the current elevator speed in of the calibrated speed or speed fraction when in differential speed mode The resolution is 0 1 and this must be divided by 10 in the PLC 12 19 9 Top...

Страница 38: ...to convert to the C units 12 19 15 Temperature Status Value State Name Description 0 NOT USED Temperature sensor input disabled in settings 1 OK No Temperature Alarm Detected 2 OPEN CIRCUIT Open Circu...

Страница 39: ...supports the remote clearing of a start lock out state which happens after a shut down because of an alarm and prevents further starts until this fault state is cleared For more information please re...

Страница 40: ...ecessary Sensor in Alarm Fault Check if the sensor is in a state of alarm and clear it Check if the sensor is powered correctly 24VDC Replace the faulty sensor if needed Bearing Temperature Sensor Ala...

Страница 41: ...n boxes are secure and in good order 2 Make sure there is no water damage to the inside of the controller or any junction boxes used 3 Verify that the TouchSwitch sensors are operational by following...

Страница 42: ...tart of this manual 16 System Breakdown Procedure In the event of the W4005V46 SYSx B system or any part of it not operating correctly the machine must be stopped immediately and the system repaired o...

Страница 43: ...power LED colour to Green 3 Updated the Temperature Alarm LED colour to Amber 4 Added the ProfiNet section 5 Added various other sections in accordance with the machinery directive 5 14 May 2014 1 Ad...

Страница 44: ...n 4 Minor syntax updates 5 Changed the alarm fault relay polarity 6 Updated system wiring diagram to R4 version 7 Added gland and thread adapter kits 8 Updated company names and addresses 9 Updated Do...

Страница 45: ...4B W4005 B HLER ELEVATOR MONITORING SYSTEM R9 6 22 May 2020 Page 45 of 48 This page is intentionally left blank...

Страница 46: ...4B W4005 B HLER ELEVATOR MONITORING SYSTEM R9 6 22 May 2020 Page 46 of 48 This page is intentionally left blank...

Страница 47: ...4B W4005 B HLER ELEVATOR MONITORING SYSTEM R9 6 22 May 2020 Page 47 of 48 This page is intentionally left blank...

Страница 48: ...l 49 0 700 2242 4091 Fax 49 0 700 2242 3733 4B FRANCE 9 Route de Corbie 80800 Lamotte Warfusee France Tel 33 0 3 22 42 32 26 Fax 33 0 3 22 42 37 33 4B COMPONENTS LTD 625 Erie Ave Morton IL 61550 USA T...

Отзывы: