background image

Page  6  of  8

Page  3  of  8

WARRANTY INFORMATION

1. EXCLUSIVE WRITTEN LIMITED WARRANTY

ALL PRODUCTS SOLD ARE WARRANTED BY THE

COMPANY (4B COMPONENTS LIMITED, (4B) BRAIME

ELEVATOR COMPONENTS LIMITED, AND (4B) S.E.T.E.M.

Sarl) HEREIN AFTER REFERRED TO AS 4B TO THE

ORIGINAL PURCHASER AGAINST DEFECTS IN

WORKMANSHIP OR MATERIALS UNDER NORMAL USE

FOR ONE (1) YEAR AFTER DATE OF PURCHASE FROM 4B.

ANY PRODUCT DETERMINED BY 4B AT ITS SOLE

DISCRETION TO BE DEFECTIVE IN MATERIAL OR

WORKMANSHIP AND RETURNED TO A 4B BRANCH OR

AUTHORIZED SERVICE LOCATION, AS 4B DESIGNATES,

SHIPPING COSTS PREPAID, WILL BE, AS THE EXCLUSIVE

REMEDY, REPAIRED OR REPLACED AT 4B’S OPTION.

2. DISCLAIMER OF IMPLIED WARRANTY

NO WARRANTY OR AFFIRMATION OF FACT, EXPRESSED

OR IMPLIED, OTHER THAN AS SET FORTH IN THE

EXCLUSIVE WRITTEN LIMITED WARRANTY STATEMENT

ABOVE IS MADE OR AUTHORIZED BY 4B. 4B SPECIFICALLY

DISCLAIMS ANY LIABILITY FOR PRODUCT DEFECT CLAIMS

THAT ARE DUE TO PRODUCT MISUSE, ABUSE OR

MISAPPLICATIONS, AS AUTHORIZED BY LAW, 4B

SPECIFICALLY DISCLAIMS ALL WARRANTIES THAT THE

PRODUCT IS FIT OR MERCHANTABLE FOR A PARTICULAR

PURPOSE.

3. NO WARRANTY “BY SAMPLE OR EXAMPLE”

ALTHOUGH 4B HAS USED REASONABLE EFFORTS TO

ACCURATELY ILLUSTRATE AND DESCRIBE THE

PRODUCTS IN ITS CATALOGS, LITERATURE, AND

WEBSITES, SUCH ILLUSTRATIONS AND DESCRIPTIONS

ARE FOR THE SOLE PURPOSE OF PRODUCT

IDENTIFICATION AND DO NOT EXPRESS OR IMPLY A

WARRANTY AFFIRMATION OF FACT, OF ANY KIND OR A

WARRANTY OR AFFIRMATION OF FACT THAT THE

PRODUCTS WILL CONFORM TO THEIR RESPECTIVE

ILLUSTRATIONS OR DESCRIPTIONS.  4B EXPRESSLY

DISCLAIMS ANY WARRANTY OR AFFIRMATION OF FACT,

EXPRESSED OR IMPLIED, OTHER THAN AS SET FORTH IN

THE EXCLUSIVE WRITTEN LIMITED WARRANTY

STATEMENT ABOVE, INCLUDING, WITHOUT LIMITATION,

THE IMPLIED WARRANTIES OF MERCHANTABILITY AND

FITNESS FOR A PARTICULAR PURPOSE.

4. LIMITATION OF DAMAGES

ANY LIABILITY FOR CONSEQUENTIAL, INCIDENTAL,

SPECIAL, EXEMPLARY, OR PUNITIVE DAMAGES, OR FOR

LOSS OF PROFIT WHETHER DIRECT OR INDIRECT, IS

EXPRESSLY DISCLAIMED.

Dear 4B Customer:

Congratulations on your purchase.  4B appreciates your business and is pleased you have chosen our

products to meet your needs.

Please read in its entirety and understand the literature accompanying the product before you place

the product into service.  Please read the safety precautions carefully before operating the product.

With each product you purchase from 4B, there are some basic but important safety considerations

you must follow to be sure your purchase is permitted to perform its design function and operate

properly and safely, giving you many years of reliable service.  Please read and understand the

Customer Safety Responsibilities listed below.  Failure to follow this safety directive and the Operation

Manuals and other material furnished or referenced, may result in serious injury or death.

SAFETY NOTICE TO OUR CUSTOMERS

A. In order to maximize efficiency and safety, selecting the right equipment for each operation

is vital.  The proper installation of the equipment, and regular maintenance and

inspection is equally important in continuing the proper operation and safety of the

product.  The proper installation and maintenance of all our products is the responsibility

of the user unless you have asked 4B to perform these tasks.

B. All installation and wiring must be in accordance with Local and National Electrical Codes

and other standards applicable to your industry.  (Please see the article “Hazard

Monitoring Equipment Selection, Installation and Maintenance” at www.go4b.com.)

The installation of the wiring should be undertaken by an experienced and qualified

professional electrician.  Failure to correctly wire any product and/or machinery can

result in the product or machine failing to operate as intended, and can defeat its design

function.

C. Periodic inspection by a qualified person will help assure your 4B product is performing

properly.  4B recommends a documented inspection at least annually and more frequently

under high use conditions.

D. Please see the last page of this manual for all warranty information regarding this product.

CUSTOMER SAFETY RESPONSIBILITIES

1.  READ ALL LITERATURE PROVIDED WITH YOUR PRODUCT

Please read all user, instruction and safety manuals to ensure that you understand your product

operation and are able to safely and effectively use this product.

2. YOU BEST UNDERSTAND YOUR NEEDS

Every customer and operation is unique, and only you best know the specific needs and capabilities

of your operation.  Please call the 24-hour hotline at 309-698-5611 for assistance with any questions

about the performance of products purchased from 4B.  4B is happy to discuss product performance

with you at any time.

3. SELECT A QUALIFIED AND COMPETENT INSTALLER

Correct installation of the product is important for safety and performance.  If you have not asked 4B

to perform the installation of the unit on your behalf, it is critical for the safety of your operation and those

who may perform work on your operation that you select a qualified and competent electrical installer

to undertake the installation.  The product must be installed properly to perform its designed functions.

The installer should be qualified, trained, and competent to perform the installation in accordance with

Local and National Electrical Codes, all relevant OSHA Regulations, as well as any of your own

standards and preventive maintenance requirements, and other product installation information

supplied with the product.  You should be prepared to provide the installer with all necessary installation

information to assist in the installation.

4. ESTABLISH AND FOLLOW A REGULAR MAINTENANCE AND INSPECTION

SCHEDULE FOR YOUR 4B PRODUCTS

You should develop a proper maintenance and inspection program to confirm that your system is in

good working order at all times.  You will be in the best position to determine the appropriate frequency

for inspection.  Many different factors known to the user will assist you in deciding the frequency of

inspection.  These factors may include but are not limited to weather conditions; construction work at

the facility; hours of operation; animal or insect infestation; and the real-world experience of knowing

how your employees perform their jobs.  The personnel or person you select to install, operate,

maintain, inspect or perform any work whatsoever, should be trained and qualified to perform these

important functions.  Complete and accurate records of the maintenance and inspection process

should be created and retained by you at all times.

5. RETAIN AND REFER TO THE OPERATION MANUAL FOR 4B’S SUGGESTED

MAINTENANCE AND INSPECTION RECOMMENDATIONS

As all operations are different, please understand that your specific operation may require additional

adjustments in the maintenance and inspection process essential to permit the monitoring device to

perform its intended function.  Retain the Operation Manual and other important maintenance and

service documents provided by 4B and have them readily available for people servicing your 4B

equipment.  Should you have any questions, please call the 4B location who supplied the product or

the 24-hour hotline number in the USA -309-698-5611.

6. SERVICE REQUEST AND ONLINE PRODUCT REGISTRATION

If you have questions or comments about the operation of your unit or require the unit to be serviced

please contact the 4B location who supplied the product or send your request via fax (309-698-5615),

email ([email protected]), or call us via our 24-hour hotline number in the USA - 309-698-5611.

Please have available product part numbers, serial numbers, and approximate date of installation.  In

order to assist you, after the product has been placed into service, complete the Online Product

Registration section which is accessed via our website 

www.go4b.com

5

UV

UV

UV

UV

UV

blue

12-240V dc

       2VA

24-240V ac

Supply

brown

3A 240V max

Non-inductive.

output Relay

black/orange

black/red

black

Apply power to the machine and 

SLIPSWITCH

.

Ensure that the machine has reached normal running

speed and then place the magnet on the 'Cal' point (located

on label on rear of unit),  Count flashes of the green LED to

set the start delay required in seconds, then remove

magnet.
The output LED will echo the setting in seconds, during

which time, automatic calibration to 20% below normal

speed will be carried out.

Recalibration for a Different Setting

If the unit is to be used for a slower speed or with longer

time delay than previously set, the unit may trip out before it

can be calibrated.  This can be avoided by applying power

while holding the magnet on the Cal point and removing the

magnet only when the machine has reached normal speed.

Wait for the green LED to illuminate permanently and then

recalibrate as above.

Connections

Introduction

The 

SLIPSWITCH

 series is designed to detect slippage or

stoppage on elevators, conveyors, fans etc.
The units require no connection with the shaft, have no

moving parts and a virtually unlimited life. They incorporate

microcontroller circuitry which automatically calibrates to

20% under normal speed and provides a programmable 0-

30 second start up delay.

Installation

The Inductive sensor section detects a metal target on the

shaft.  The target can be an existing bolt head or similar.
Ideally, the target should be of ferrous metal but non ferrous

metal will be detected at short range.  Maximum range

ferrous/non-ferrous materials is 12/5mm with a 30mm

diameter circular target.  Smaller targets may be used but

operating distance will be reduced.
The 

SLIPSWITCH

 should be mounted adjacent to the

target, ensuring that the distance to the target does not

exceed the stated maximum. When mounted against a solid

steel shaft, the target or bolt head should protrude from the

shaft at least 15mm, otherwise the sensor will not be able to

distinguish the target from the shaft and red input light would

stay on permanently.
Wiring to the 

SLIPSWITCH

 can be any length as required,

using ordinary unscreeened cable. However, if long cable

runs are to be used, the wiring should 

not

 be positioned

adjacent to cables  carrying high voltage or current.
Two locknuts are provided to mount the units in position.

Mount securely to withstand vibration.Ensure that the unit

and target are adequately  guarded.

Cabling

Connect the unit as shown in the connections diagram.

Commissioning & Auto-calibration.

Two LED's are provided for information purposes, on the

SLIPSWITCH

. The input LED is red and flashes everytime

a target passes the face of the sensor. The output LED is

green. With normal running, the output LED is a static

green and the output is on (energised).
With an underspeed condition both the LED and output will

be off  (de-energised). The 

SLIPSWITCH

 is factory set to a

speed of 10PPM and a start up time of 5 seconds.  If the

time delay required is greater than 5 seconds, see

'Recalibration for a Different Setting', otherwise, proceed as

follows-

Low Risk

Dimensions (in mm)

12345678901234

12345678901234

12345678901234

12345678901234

12345678901234

12345678901234

12345678901234

12345678901234

12345678901234

12345678901234

12345678901234

12345678901234

12345678901234

12345678901234

12345678901234

12345678901234

92

30

36

30mm x 1.5mm

<12

5 Metres cable

 

Output LED

Green

Sensing LED

Red

Page  4  of  8

Page  5  of  8

Содержание SLIPSWITCH M300

Страница 1: ...05V10CA CSA ATEX APPROVED SELF CONTAINED UNDERSPEED MONITOR Manual No M2479 INSTALLATION INSTRUCTIONS UNDERSPEED MONITOR M3005V10CA PROGRAMMABLE UNDERSPEED MONITOR M300 CSA ATEX Approved TECHNICAL INFORMATION Page 1 of 8 ...

Страница 2: ...ct is important for safety and performance If you have not asked 4B to perform the installation of the unit on your behalf it is critical for the safety of your operation and those who may perform work on your operation that you select a qualified and competent electrical installer to undertake the installation The product must be installed properly to perform its designed functions The installer ...

Страница 3: ...rom the shaft at least 15mm otherwise the sensor will not be able to distinguish the target from the shaft and red input light would stay on permanently Wiring to the SLIPSWITCH can be any length as required using ordinary unscreeened cable However if long cable runs are to be used the wiring should not be positioned adjacent to cables carrying high voltage or current Two locknuts are provided to ...

Страница 4: ...ifferentSetting If the unit is to be used for a slower speed or with longer time delay than previously set the unit may trip out before it can be calibrated This can be avoided by applying power while holding the magnet on the Cal point and removing the magnet only when the machine has reached normal speed Wait for the green LED to illuminate permanently and then recalibrate as above Connections L...

Страница 5: ...CT CLAIMS THAT ARE DUE TO PRODUCT MISUSE ABUSE OR MISAPPLICATIONS AS AUTHORIZED BY LAW 4B SPECIFICALLY DISCLAIMS ALL WARRANTIES THAT THE PRODUCT IS FIT OR MERCHANTABLE FOR A PARTICULAR PURPOSE 3 NO WARRANTY BY SAMPLE OR EXAMPLE ALTHOUGH 4B HAS USED REASONABLE EFFORTS TO ACCURATELY ILLUSTRATE AND DESCRIBE THE PRODUCTS IN ITS CATALOGS LITERATURE AND WEBSITES SUCH ILLUSTRATIONS AND DESCRIPTIONS ARE F...

Страница 6: ...Accuracy 1 Start Up Delay Adjustable to 0 30 seconds Operation Setting Automatic calibration by applying magnet to Cal point Relay de energises at 20 under set speed Enclosure Moulded Nylon DIN threaded 30mm by 1 5mm pitch Protection IP65 Relative Humidity 90 RH LED Indication Target Detected Output Cable Supplied with 2 metres 5 core 600 1000V flame retardant to EN60332 1 Baseefa Approval CSA App...

Отзывы: