PAGE 13
TIME DELAY -
The Auto-Set has an adjustable delay from 0 to 60 seconds, the timer operating on both material arriving
and leaving.
To set the time delay, proceed as follows:
10.
Set the Cal/Park switch (A - Image D) to Cal.
11. Press and hold the timer button (G - Image D), the display will show T000 (zero delay). To
set a time delay, continue to hold the timer button and the display will start to increase by
1 second increments (maximum delay is 128 seconds). When the required delay time is
shown, release the timer button. To reset the delay, press and hold the timer button again to
restart the entire process from T000 (zero delay).
12.
Return the Cal/Park switch (A - Image D) to Park and press the timer button (G - Image D) to
confirm the timer setting.
13. The timer can be altered to a longer or shorter delay by repeating the entire procedure from
steps 10 to 12.
NOTE
For questions regarding non-standard Digimatic probe lengths or diameters, contact 4B.