background image

4

GENERAL SAFETY INSTRUCTIONS

IMPROPER USE

PROPER USE

 WARNING: Important safety instructions.  

  Follow all instructions as incorrect installation may result in serious injury.

 WARNING: The drive must be disconnected from the power source during cleaning, maintenance and replacement of parts.

 Danger to life from electric shock when working on electrical equipment. 

 The electrical connection, installation and commissioning of the receiver may only be carried out by qualified personnel.  

 Before installing the drive, remove all unnecessary cables and disable all devices,  

  that are not required for operation with power.

 The relevant regulations and guidelines must be followed without fail, to avoid damage to persons and objects.

 Observe safety instructions according to EN 60 335-2-97: The power supply cable of the drives must be laid internally.

 Installation according to DIN 18073: The roller shutter box cover must be easily accessible and removable.

 Installation according to EN 60335: Only switches / pushbuttons / switching devices with a minimum contact opening 

  of 3 mm may be used, furthermore the up and down direction must be interlocked against each other.

 When installing in damp rooms, observe regulations (VDE 0100, part 701 and 702).

 Please never operate several motors via one switch / pushbutton, unless you are using  

  cut-off relays or other controls that allow parallel operation.

 Do not use defective devices: Never use defective equipment. 

  Periodically inspect the equipment for imbalance and signs of wear or damage to cables and suspension springs. 
  Do not use equipment if repair or touch-up is necessary. 
  There is a risk of personal injury and property damage due to electric shock or short circuit.

 Retain the instructions for future reference.

 Use tubular motors only for automating shutters.

 Only use original components and original accessories from the manufacturer. 

 The mains connection cable of the drives must be laid internally in the empty conduit up to the junction box. 

  The local electrical regulations must be observed.

 For the electrical connection of the tubular motors, a 230 V / 50 Hz 

  power connection with fuse must be available at the installation site.

 Inspect the installation frequently for imbalance and signs of wear or damage to cables and springs. 

  Do not use if repairs or adjustments are required.

3T-MOTORS Tubular motors

  |  Safety instructions

Please read these important safety instructions before commissioning!

Incorrect installation can cause serious personal injury and damage to property. 
The warranty claim expires in case of non-observance of this user information with all contained notes and regulations.
In case of non-observance of these instructions, the manufacturer or supplier shall not be liable for any personal injury or property damage incurred.

 SAFETY INSTRUCTIONS

This symbol indicates danger due to electrical energy. 

Danger to persons and objects may arise if the 

associated information is not observed!  

This symbol indicates information about general danger. 

Non-observance can mean danger to 

persons and objects!

This symbol indicates important information that can 

ensure safe and proper use of the device.

 Persons are to be instructed with the correct operation of the tubular motor. 

 The roller shutter movement must be monitored in order not to endanger persons. 

 Do not allow children to play with motor controls.

 Store the handheld transmitter in such a way that unintentional operation is prevented (e.g. by children playing).

 The device can be used by children aged 8 years and above and persons with reduced physical, sensory or mental 

  capabilities or lack of experience and knowledge, if they have been given supervision and instruction concerning use 
  of the appliance in a safe way and are aware of the hazards involved.

 Children are not allowed to play with the equipment.

 If the power supply cord of this device is damaged, it must be replaced by the manufacturer or its customer service 

  or a similarly qualified person to prevent hazards.

Содержание 3T-MOTORS 3T45

Страница 1: ...EEE Reg Nr DE 77028333 INTELLIGENT DRIVES CONTROLS FOR SHUTTERS AND AWNINGS 3T MOTORS Shutter Awning motors with mechanical limit switches INSTALLATION OPERATING INSTRUCTIONS Instructions and notes fo...

Страница 2: ...wning motor Page 14 16 1 Preparation Page 14 2 Prepare motor for installation Page 14 3 Mounting awning motor Page 14 15 4 Awning motor wiring Page 15 5 Setting the end positions Page 16 Troubleshooti...

Страница 3: ...account rail guidance of approx 10 Roller shutter area m x Weight roller shutter material m Weight roller shutter kg 10 Friction losses Required traction force kg Example PVC Roller shutter area 3 00...

Страница 4: ...ble of the drives must be laid internally in the empty conduit up to the junction box The local electrical regulations must be observed For the electrical connection of the tubular motors a 230 V 50 H...

Страница 5: ...COPE OF DELIVERY MOTOR TYPE 3T45 1 Motor 2 Limit switch adapter 3 Shaft adapter 4 Connection cable 3 meters 5 Adjustment pin 6 Universal bearing cotter pin 7 Cover cap bearing 8 Securing bracket 9 Man...

Страница 6: ...d Steel shafts with an internal fold will damage and destroy the motor Grinding marks of any kind on the motor housing will void the warranty The inspection cover of the roller shutter box must be eas...

Страница 7: ...45 and 3T35 Universal bearing 3T45 3T35 and cover cap bearing 3T45 clip bearing 3T35 Use one of the two motor bearings depending on the installation situation 1 2 3 4 5 6 7 8 9 10 11 Please note The m...

Страница 8: ...clips Motor type 3T35 Installation with universal bearing or clip bearing Installation with universal bearing Push the motor with the square into the opening of the bearing and secure with cotter pin...

Страница 9: ...limit switch adapter fig 4 7 4 8 5 Mount bearings Remove old wall bearing on motor side left or right installation possible Mount motor bearing at this point 2 mounting options Universal bearing and...

Страница 10: ...el If the drive should run in the opposite direction after installation the motor s upstream and downstream leads brown black must be turned The connection diagram of time switches differs from this c...

Страница 11: ...head only Motor type 3T45 Power cable to rear Motor type 3T35 Power cable to rear Motor type 3T45 Power cable to front The straight up and down arrows indicate the direction of rotation of the motor a...

Страница 12: ...shutter to move upwards until the motor stops automatically at the previously set upper end position To set the upper end position turn the adjustment pin on the limit switch screw for the upper end p...

Страница 13: ...W40 only use shafts with an external fold Steel shafts with an internal fold will damage and destroy the motor Explanation Avoid overstressing and resulting premature aging of the motor by using the c...

Страница 14: ...e support tube fig 3 4 Remove the crank mechanism fig 3 5 Attention Awning arms are under strong tension 2 1 Limit switch adapter Motor head 2 2 2 3 Securing bracket 2 4 Click Shaft adapter Side beari...

Страница 15: ...may only be carried out by qualified personnel If the drive should run in the opposite direction after installation the motor s upstream and downstream leads brown black must be turned 3 9 3 10 3 11...

Страница 16: ...h screw in the PLUS direction until the desired position is reached and the awning is fully retracted If the awning motor travels too far While the tubular motor is moving in the relevant direction EX...

Страница 17: ...itch screw in the MINUS direction up to 100 turns depending on the motor type until the motor switches off Then allow the roller shutter shaft to rotate in the opposite direction and turn the other li...

Страница 18: ...rungen der aufgef hrten EG EU Richtlinien erf llt Maschinenrichtlinie 2006 42 EG EMV Richtlinie 2014 30 EU RoHS Richtlinie 2011 65 EU Delegierte Richtlinie EU 2015 863 WEEE Richtlinie 2012 19 EU angew...

Страница 19: ...m 140 cm 160 cm Suspension spring Maxi Required when using roller shutter motors Maxi spring up to 65 mm profile height For roller shutter shaft SW60 Powder coated Anti burglary effect Pick up width 1...

Страница 20: ...FOR SHUTTERS AND AWNINGS Service and Quality make the difference 3T Components GmbH Co KG Bahnhofstr 34 55578 Wallertheim Email info 3t components de Tel 49 0 6732 600 03 69 Fax 49 0 6732 600 54 30 ww...

Отзывы: