background image

installation.

Mains Supply 230Vac

The mains power supply cable is pre-wired. Connect to a fused outlet or isolator as usual. This is a 
Class 2 isolated appliance without earth, but the earth wire must still be connected and validated 

as usual to provide safety in the event of damage to the supply cable.

Current draw is shown at the end of this manual under Specifications.

NOTE – Do not coil the cables, cut them to an appropriate length. Coiled cables suffer increased 
impedance and are susceptible to voltage induction from nearby circuits and appliances. Where 

possible try to maintain a separation of at least 150mm between mains power cables and low 
voltage cables. 

Operation

Safety Precautions

Mains Voltage – There are exposed electrical conductors inside this appliance. This appliance must 

be installed and serviced by a competent electrical technician to the current requirements of 
BS7671 and IEEE recommendations. Before servicing this appliance, normal safe isolation 

procedures should be implemented.

Do not touch any connection terminals while energised.

Do not attempt to service this item when wet, or in a wet or high humidity environment.

If the housing of the control panel becomes damaged, you must shut down and securely isolate 

this appliance immediately.

Adjustments

Operation is automatic. There are no adjustments to be made at the control unit.

Non-weighted float cables

The level around which the system starts and stops the top-up cycle can be adjusted by moving the 
point at which the float cable is attached within the tank. 

The top-up duration can be adjusted by increasing or decreasing by the length of free cable to the 

3P TCS5JBL/TCS5JBLA 

Page 5 

11/09/16

Содержание TCS5JBLA

Страница 1: ...3P Technik TCS5JBL TCS5JBLA Low Voltage Top Up Switch Installation and Operation Manual 3P TCS5JBL TCS5JBLA Page 1 11 09 16 ...

Страница 2: ...tallation 2 Safety Precautions 2 Included Components 3 Layout 3 Control Panel Mounting 3 Connections 4 Float Switch 4 Solenoid 4 Mains Supply 230Vac 4 Operation 4 Safety Precautions 4 Adjustments 5 Specifications 5 3P TCS5JBL TCS5JBLA Page 2 11 09 16 ...

Страница 3: ...or 24Vac TCS5JBLA with limited current and over voltage protection Installation Safety Precautions Mains Voltage There are exposed electrical conductors inside this appliance This appliance must be installed and serviced by a competent electrical technician to the current requirements of BS7671 and IEEE recommendations Before servicing this appliance normal safe isolation procedures should be impl...

Страница 4: ...t protection and residual current protection at 30mA ideally on it s own circuit but always in accordance with BS7671 and applicable regulations Control Panel Mounting Open the cover of the control panel There are 4 recesses one on each corner of the panel Drill through at these locations and attach to the wall or a suitable support taking care not to damage cabling inside the panel Fixings are no...

Страница 5: ... conductors inside this appliance This appliance must be installed and serviced by a competent electrical technician to the current requirements of BS7671 and IEEE recommendations Before servicing this appliance normal safe isolation procedures should be implemented Do not touch any connection terminals while energised Do not attempt to service this item when wet or in a wet or high humidity envir...

Страница 6: ...and stops the top up cycle can be raising or lowering the float into the tank The top up duration can be adjusted by increasing or decreasing by the length of free cable between the float and the weight Specifications Dimensions W x H x D 130mm x 94mm x 57mm Enclosure Material Polystyrene Ingress Protection IP66 UV Resistant Output TCS5JBL 24Vdc 0 63A max TCS5JBLA 24Vac 1 25A max 3P TCS5JBL TCS5JB...

Отзывы: