Attention before mounting:

 

 

Don't place or install the device in area near water or 

moist, keep the relative humidity of the device 

surrounding between 5%~95% without condensation. 

 

Before power on, first confirm the supported power 

supply specification to avoid over-voltage damaging the 

device. 

 

The device surface temperature is high after running; 

please don't directly contact to avoid scalding. 

Wall-mounting the Device

 

 

Put  the  device  on  the  wall  it  will  be  mounted  as 

Step 1

reference or to refer to its mounting dimension, and 

mark the locations of the 4 expansion screws.   

 

Mount  the  screws  on  the  wall  and  reserve  7mm 

Step 2

void.   

 

Hang  the  device  on  the  4  expansion  screws  and 

Step 3

slide  it  down,  then  tighten  the  screws,  mounting 

ends.   

 

Disassembling the Device

 

Step 1 

Device powers off 

Step 2 

Unscrew the screws on the wall about 7mm.   

Step 3 

Lift the device then take it out, disassembling ends.   

Note: 

 

Power ON operation: first connect power line to the 

connection terminal of device power supply, then power 

on. 

 

Power OFF operation: first unpin the power plug, then 

remove the power line, please note the operation order 

above.   

Power Supply Connection

 

 

DC power supply 

The series devices provide 1 power supply 

input. The interface adopts M12 A-Coded 4-pin 

needle (male) connector, which could be 

connected to M12 A-Coded 4-pin slot (female). 

Power supply range: 110VDC (70-160VDC). 

The pin definitions of M12 (Male) are as follows: 

No. 

Definition 

FG 

V- 

V+ 

NC 

Description 

Ground  Power 

input   

negative 

Power 

input 

positive 

reserved 

 

 

 

Relay Connection

 

This device provides 1 M12 D-Coded 4-Pin slot 

(female) for relay output. R1 and R2 is a pair of 

normally open contacts of device alarm relay. 

They are open circuit in normal non alarm state, 

closed when any alarm information occurs. 

Such as: it's closed when power off, and send out alarm. This 

series switches support 1 channel relay alarm information 

output, support DC power alarm information or network 

abnormal alarm output, it can be connected to alerting lamp, 

alarm buzzer, or other switching value collecting devices for 

timely warning operating staffs when alarm information occurs. 

The pin definitions of relay are as follows: 

No. 

Definiton 

R1 

R2 

NC 

NC 

Console Port Connection

 

This  device provides 1  program  debugging  port 

based  on  RS232,  which  could  be  connected  to 

PC for  device  CLI command management.  The 

interface  adopts  M12  D-Coded  4-pin  slot 

(female). The pin definitions of M12 are as follows:   

No. 

Definition 

TX 

RX 

NC 

GND 

Description 

RS-232 

sending 

signal 

RS-232 

receiving 

signal 

Reserved  Ground 

Communication Interface Connection

 

 

M12 100M Copper Port 

This  device  provides  8  10/100Base-T(X)  ports. 

The  interface  type  is  M12  D-Coded  4-pin  slot 

(female).  The  pin  definitions  of  M12  are  as 

follows: 

No. 

Definition 

Description 

TD+ 

100M Ethernet transmitted 

signal Positive 

TD- 

100M Ethernet transmitted 

Содержание TNS5800D Series

Страница 1: ...ed for rail transit industry The module is TNS5800D 4GT 8T 4 Gigabit copper ports 8 100M copper ports Panel Design Front view Bottom view Top view Left view Right view 1 Hanger 2 Relay alarm output terminal block 3 Console port 4 Indicator of power supply input status PWR 5 Relay alarm indicator ALARM 6 Indicator of device running status RUN 7 Grounding screw 8 Power input terminal block 9 10 100 ...

Страница 2: ...emale Power supply range 110VDC 70 160VDC The pin definitions of M12 Male are as follows No 1 2 3 4 Definition FG V V NC Description Ground Power input negative Power input positive reserved Relay Connection This device provides 1 M12 D Coded 4 Pin slot female for relay output R1 and R2 is a pair of normally open contacts of device alarm relay They are open circuit in normal non alarm state closed...

Страница 3: ...N ON The device is powered on or the device is abnormal OFF The device is powered off or the device is abnormal Blinking Blink 1 time s system is running well Link Act 1 8 G1 G4 ON Ethernet port connection is active Blinking Data transmitted OFF Ethernet port connection is inactive Logging in to WEB Interface This device supports WEB management and configuration Computer can access the device via ...

Страница 4: ...output M12 D coded port Indicator Power indicator run indicator interface indicator alarm indicator Exchange attributes Backplane bandwidth 128G Packet buffer size 12Mbit MAC table size 16K Power supply Input power supply 110VDC 70 160VDC M12 A coded port Consumption No load 14 30W 110VDC Full load 14 85W 110VDC Working environment Working temperature 40 75 Storage temperature 40 75 Working humidi...

Отзывы: