3onedata SW4485 Скачать руководство пользователя страница 2

protection(contact discharge) and 2-stage radiation

immunity

Industrial design, IP40 protection

Support DIN-Rail and wall mounting installation

Working Temperature: -40

~85

Panel Layout

Main view

Top view

Bottom view

1. RS-485 PC port

3PIN terminal

2. RS-232 PC port

DB9F

3. Company name, product line identification

4. hangers

5. Power indicator

PWR

6. data transmit status indicator(TXD)

7. data receiving status indicator(RXD)

8. Indicator of RS-485 lower position controller port

E1~E4

9. RS-485 lower position controller port( 10PIN terminal

block)

10. DC-5V Power interface

Dimensions

Unit

mm

Power Input

The lower panel of SW4485 HUB provides access

port of DC power, wherein the power input is 5VDC.

Recommend to use the power adapter of DC head

specification with 2.5mm inner diameter and 5.5mm

outer diameter.

Communication Interface

RS-232 PC interface

For SW4485, RS-232 port is a standard

DB9F

socket,

pin

definition

is

consistent

with

RS-232

specification, here is the three-wire connection.

Distribué

par

 GMI

-Databo

x  

T

el:
 01

69

 90

 03

 03

0

9

 70
 61
 64
 1

9

 

v

entes@

g

midatabox.fr

 

 

 

Fax
 : 

Содержание SW4485

Страница 1: ...cture split network segment You can design a unique and reliable RS 485 system through making reasonable use of SW4485 SW4485 adopts EMC protection design supports wall mounting and panel mounting installation and can be used at the harsh environment from 40 to 85 Packing List The first time use this product please check the packaging is intact or not and the attachment is complete or not at first...

Страница 2: ...S 485 lower position controller port E1 E4 9 RS 485 lower position controller port 10PIN terminal block 10 DC 5V Power interface Dimensions Unit mm Power Input The lower panel of SW4485 HUB provides access port of DC power wherein the power input is 5VDC Recommend to use the power adapter of DC head specification with 2 5mm inner diameter and 5 5mm outer diameter Communication Interface RS 232 PC ...

Страница 3: ... signal of RS 485 input out side 4 2D signal of RS 485 input out side 5 3D signal of RS 485 input out side 6 3D signal of RS 485 input out side 7 4D signal of RS 485 input out side 8 4D signal of RS 485 input out side 9 GND Signal Ground 10 GND Signal Ground RS 485 Port fault alarm and protection RS 485 port fault alarm and protection is the solution to connect multiple RS 485 devices an effective...

Страница 4: ...ws nuts and tools to ensure reliable installation Power 5VDC Environment Working Temperature 40 85 Humidity 5 95 Installation Type Wall mount and Panel mount Cable Laying Cable laying should meet the following conditions Check all cable specifications models and quantity meet the demand or not before cable laying Check the cable is damaged or not whether has factory leaving record and quality assu...

Страница 5: ...n 5m Interface mode RS 232 PC port mode DB9M Male RS 485 PC port mode 3PIN terminal RS 485 Lower Position Controller port mode 10PIN terminal Indicator PWR power indicator TXD data transmit status indicator RXD data receiving status indicator E1 E4 status indicator of RS 485 lower position controller interface Power Input 5VDC No load Power 0 455W 5VDC Full Power 0 485W 5VDC Mechanical Structure S...