PS5026G-2GS-24PoE User Manual

PS5026G-2GS-24PoE

Managed Full Gigabit

Industrial Ethernet PoE Switch

User Manual

Version 1.0, 2017.8.29

Содержание PS5026G-2GS-24PoE

Страница 1: ...PS5026G 2GS 24PoE User Manual PS5026G 2GS 24PoE Managed Full Gigabit Industrial Ethernet PoE Switch User Manual Version 1 0 2017 8 29 ...

Страница 2: ...ter NIC to the Switch 10 Chapter 3 How to Login the Switch 11 3 1 How to Login the Switch 11 Chapter 4 Switch Configuration 13 4 1 Quickly Set 13 4 2 PORT 16 4 2 1 Basic Config 16 4 2 2 Port Aggregation 17 4 2 3 Port Mirroring 18 4 2 4 Port Limit 20 4 2 5 Storm Control 21 4 2 6 Port Isolation 21 4 3 VLAN 22 4 3 1 VLAN setting 23 4 3 2 Trunk port setting 24 4 3 3 Hybrid port setting 25 4 4 Fault Sa...

Страница 3: ...able 52 4 9 1 Mac add and delete 53 4 9 2 Mac study and Aging 54 4 9 3 Mac address filtering 55 4 10 SNMP 56 4 10 1 SNMP Config 56 4 10 1 1 SNMP Config 56 4 10 1 2 Community Config 57 4 10 1 3 Group Config 57 4 10 1 4 User config 58 4 10 1 5 Trap 60 4 10 1 6 View config 61 4 10 2 Rmon Config 62 4 10 2 1 Statistics Group 62 4 10 2 2 History Group 63 4 10 2 3 Alarm Group 64 4 10 2 4 Event Group 65 4...

Страница 4: ...l 3 4 11 3 1 Current configuration 74 4 11 3 2 Configuration backup 76 4 11 3 3 Restore factory configuration 76 4 11 4 Config Save 77 4 11 5 Administrator Privileges 78 4 11 6 Info Collect 79 Appendix Technical Specifications 80 ...

Страница 5: ...nty of VLAN function easy to maintenance and management meet the networking and access requirements of small and medium sized enterprises intelligent village hotel office network and campus network This Switch 24 ports support POE power supply function support IEEE802 3at standard 802 3af downward compatibility power supply equipment for Ethernet can automatically detect identification standard of...

Страница 6: ... a bandwidth of 1000Mbps Each has a corresponding 1000Mbps LED CONSOLE port CONSOLE Designed to connect with the serial port of a computer or terminal for monitoring and configuring the Switch RESET button RESET Keep the device powered on and press down the button for about 5 seconds The system restores the factory default settings LED indicators The LED Indicators will allow you to monitor diagno...

Страница 7: ...g to the power limits of the port Flashing The PoE power circuit may be in short or the power current may be overloaded 1 3 2 Rear Panel The rear panel of the Switch contains AC power connector and one marker shown as below AC Power Connector Power is supplied through an external AC power adapter It supports AC 100 240V 50 60Hz Grounding Terminal The Switch already comes with Lightning Protection ...

Страница 8: ...g the packing list listed OK If any part is lost and damaged please contact your local agent immediately In addition make sure that you have the tools install switches and cables by your hands One PoE Managed Ethernet Switch Four rubber feet two mounting ears and eights screws One AC power cord One User Manual ...

Страница 9: ... input range and matches the voltage labeled on the Switch To keep the Switch free from lightning do not open the Switch s shell even in power failure Make sure that there is proper heat dissipation from and adequate ventilation around the Switch Make sure the cabinet to enough back up the weight of the Switch and its accessories 2 1 1 Desktop Installation Sometimes users are not equipped with the...

Страница 10: ...gure 5 Bracket Installation b use the screws provided with the equipment rack to mount the Switch on the rack and tighten it Figure 6 Rack Installation 2 1 3 Power on the Switch The Switch is powered on by the AC 100 240V 50 60Hz internal high performance power supply Please follow the next tips to connect AC Electrical Outlet It is recommended to use single phase three wire receptacle with neutra...

Страница 11: ...onnect Computer NIC to the Switch Please insert the NIC into the computer after installing network card driver please connect one end of the twisted pair to RJ 45 jack of your computer the other end will be connected to any RJ 45 port of the Switch the distance between Switch and computer is around 100 meters Once the connection is OK and the devices are power on normally the LINK ACT Speed status...

Страница 12: ...he configuration window of the Switch through following steps 1 Connect the Switch with the computer NIC interface 2 Power on the Switch 3 Check whether the IP address of the computer is within this network segment 192 168 2 xxx xxx ranges 2 254 for example 192 168 2 100 4 Open the browser and enter http 192 168 2 1 and then press Enter The Switch login window appears the following picture 5 Enter...

Страница 13: ...PS5026G 2GS 24PoE User Manual 12 ...

Страница 14: ...I the left column shows the configuration menu Above you can see the information for switch system such as memory The middle shows the switch s current link status Green squares indicate the port link is up while gray squares indicate the port link is down The rest of the screen area displays the configuration settings 4 1 Quickly Set In the navigation bar to select Quickly Set can create a VLAN i...

Страница 15: ... is considered belongs to the VLAN Obviously the interface of the default VLAN ID PVID in the IEEE 802 1 Q VLAN ID is the Native VLAN At the same time send belong to Native VLAN frame on the Trunk must adopt UNTAG way Allowed VLAN list A Trunk can transport the equipment support by default all the VLAN traffic 1 4094 But also can by setting the permission VLAN Trunk at the port of the list to limi...

Страница 16: ...ck next step button into other settings such as Manage IP address set as 192 168 2 11 device name set as Switch 123 Default gateway set as 192 168 2 22 DNS server set as 172 16 1 241 Use 192 168 2 11 to log in set a new password for 1234 ...

Страница 17: ...ion 4 2 1 Basic Config In the navigation bar to select Port Basic Config for panel port to port described port speed port status working mode flow control cross line order configuration as shown Parameter Descriptionion Parameter Description Port Select the current configuration port number Port status Open or close ports Flow control Open or close the port flow control function ...

Страница 18: ...tructions Open flow control should be negotiated will close negotiated close is to set port speed rate and working mode Set the port rate more than actual rate of port the port will be up Configuration Example Such as The port is set to 10M Duplex cross line sequence set to Auto open flow control and port state 4 2 2 Port Aggregation In the navigation bar to select Port Port Aggregation in order t...

Страница 19: ...t 1 connected to other switch aggregation port 1 to build switch links 4 2 3 Port Mirroring In the navigation bar to select Port Port Mirroring open port mirror feature all packets on the source port are copied and forwarded to the destination port destination port is usually connected to a packet analyzer to analyze the source port multiple ports can be mirrored to a destination port as shown ...

Страница 20: ...t Set destination port All packets on the source port are copied and forwarded to the destination port Instructions The port of the aggregate port can not be used as a destination port and the source port destination port and source port can not be the same Configuration Example Such as Set a mirror group for port 10 regulatory port 4 6 8 on and out flow conditions ...

Страница 21: ...wn Parameter Description Parameter Description Input speed limit Set port input speed Output speed limit Set port output speed Instructions 1Mbit s 1000Kbit s 1000 8KB s 125KB s That is the theoretical rate of 1M bandwidth is 125KB s Configuration Example Such as The port 9 input rate is set to 6400KB s the output rate is set to 3200KB s ...

Страница 22: ...PS5026G 2GS 24PoE User Manual 21 4 2 5 Storm Control 4 2 6 Port Isolation In the navigation bar to select Port Port Isolation one port can be isolated to one or multiple destination ports as shown ...

Страница 23: ... the isolated port Isolated port Port will be isolated Configuration Example Such as Isolate port 5 6 7 8 port separately Configuration success after Isolate port 5 6 7 8 port separately 4 3 VLAN In the navigation bar to select VLAN You can manage the VLAN setting Trunk port Setting and Hybrid port Setting as shown ...

Страница 24: ...meter Description Parameter Description VLAN ID VLAN number 26GE default VLAN 1 VLAN name VLAN mark VLAN IP address Manage switch ip address Instructions Management VLAN the default VLAN cannot be deleted Add ports to access port port access mode can only be a member of the VLAN Configuration Example Such as Connect switches pc1 pc2 couldn t ping each other will be one of the PC connection port be...

Страница 25: ...to UNTAG send or receive a message on the interface is considered belongs to the VLAN Obviously the interface of the default VLAN ID PVID in the IEEE 802 1 Q VLAN ID is the Native VLAN At the same time send belong to Native VLAN frame on the Trunk must adopt UNTAG way Allowed VLAN list A Trunk can transport the equipment support by default all the VLAN traffic 1 4094 But also can by setting the pe...

Страница 26: ...whether there is a VLAN information if there is no play in port PVID exchanged and forwarding if have whether the Hybrid port allows the VLAN data into if can be forwarded or discarded untag on port configuration is not considered untag configuration only work when to send it a message Hybrid port to send packet 1 Determine the VLAN in this port attributes disp interface can see the port to which ...

Страница 27: ...s at this time to remove packet VLAN10 tag in the form of ordinary package sent to pc2 pc1 p2 is VLAN10 walking at this time Again to analyze pc2 gave pc1 package process data from the pc2 by inter0 2 pvid VLAN20 encapsulation VLAN20 labeled into switch switch found system e0 1 allows VLAN by 20 data so the data is forwarded to the system e0 1 because the system e0 1 on the VLAN is untagged 20 the...

Страница 28: ...letion attack packets ban kangaroo DHCP server as shown Instructions DHCP trusted port configuration select the port as a trusted port Prohibit DHCP for address select the port and save you can disable this feature for the port Open DHCP attack prevention function need to set the DHCP protective VLAN simultaneously other functions to take effect Configuration Example Such as 1 DHCP snooping open 2...

Страница 29: ... 2GS 24PoE User Manual 28 3 Set the connection router 10 ports for trust then 6 port is set to the prohibit 3 Verify source mac F0 DE F1 12 98 D2 set server IP address to 192 168 2 1 4 Set option82 information ...

Страница 30: ...ing 4 4 1 2 DOS In the navigation bar to select Fault Safety Anti Attack Anti DOS open the anti DOS attack function intercept land attack packets illegal TCP packets to ensure that the device or server to provide normal service to legitimate users as shown ...

Страница 31: ...navigation bar to select Fault Safety Anti Attack IP Source Guard through the source port security is enabled on port forwarding the packet filter control prevent illegal message through the port thereby limiting the illegal use of network resources improve the safety of the port as shown Instructions Add the port that is currently being used as a IP source protection enable port the port will not...

Страница 32: ... MAC address of the mapping relationship and then realize the function of a key binding as shown Instructions A bond must be bound before the binding to enable the switch to open and if you want to access shall be binding and switch the IP address of the same network segment Configuration Example Such as The binding to make first can open must be a key bindings port 7 ...

Страница 33: ...r to select Fault Safety Channel Detection Ping testing use ping function to test internet connect and host whether to arrive as shown Parameter Description Parameter Description Destination IP address Fill in the IP address of the need to detect Timeout period Range of 1 to 10 Repeat number Testing number Instructions ...

Страница 34: ... and host whether to arrive Configuration Example Such as Ping connect the IP address of the PC 4 4 2 2 Tracert In the navigation bar to select Fault Safety Channel Detection Tracert testing tracert detection can detect to the destination through as shown Parameter Description ...

Страница 35: ...ruction The function is used to detect more is up to and reach the destination path If a destination unreachable diagnose problems Configuration Example Such as Ping connect the IP address of the PC 4 4 2 3 Cable test In the navigation bar to select Fault Safety Channel Detection Cable testing can detect connection device status as shown Configuration Example ...

Страница 36: ... Basic principles 1 According to the order as long as there is a meet will not continue to find 2 Implied refused if don t match so must match the final implied refused entry cisco default 3 Any only under the condition of the minimum permissions to the user can satisfy their demand 4 Don t forget to apply the ACL to the port Configuration Example Such as Test time is every Monday to Friday 9 to 1...

Страница 37: ...PS5026G 2GS 24PoE User Manual 36 4 5 PoE In the navigation bar to select PoE you can set PoE Config and PoE port Config configuration ...

Страница 38: ...Supply mode Select the mode of PSE power supply Alarm power Configuration of the alarm threshold Reserved power Configuration to keep power Alarm notice State configuration warning announcement Instruction In practical application it is required to control the system to transmit trap notification when the power change and the port are up and down Receive the Trap notices the Snmp must be open and ...

Страница 39: ...owing picture Parameter description Parameter Description Alarm threshold Configuration temperature alarm threshold the range of 70 149 Instruction Receive the Trap notices the Snmp must be open and set the Trap to the target host Configuration example Such as 1 warning threshold is set to 80 chip chip 2 warning threshold is set to 100 chip 3 alarm threshold is set to 120 ...

Страница 40: ...Enable Select configuration can make state Priority Configure port priority when the load exceeds the PoE power low priority under the port of equipment will be dropped first Detection mode Configure port detection mode Instruction Receive the Trap notices the Snmp must be open and set the Trap to the target host Configuration example such as port 8 enable set to active will set the maximum power ...

Страница 41: ...In the navigation bar to select MSTP MSTP Region can modify the domain and domain name add instance is mapped to a VLAN as shown Parameter Description Parameter Description Region name Configure the region name Revision level Parameter configuration revision level Instance ID Select configuration instance ID VLAN ID Mapping of the VLAN configuration instance ...

Страница 42: ...n the first need to create a VLAN 2 4 6 2 MSTP Bridge In the navigation bar to select MSTP MSTP Bridge can be related to bridge port configuration as shown Parameter Description Parameter Description Inst priority Whether open instance priority setting Instance ID Select the created instance id is configured Enable Whether to open the STP bridge function Bridge priority Priority setting bridge exa...

Страница 43: ...ion state Auto ege Select configuration state Point to point Select configuration state Bpdu guard Select configuration state Bpdu filter Select configuration state Compatible Select configuration state Root guard Select configuration state TC guard Select configuration state TC filter Select configuration state Instruction 1 hello_time 1 2 max_age f_delay 1 2 enable the switch to set instance pri...

Страница 44: ...STP has launched port configuration select the created instance set priority port configuration is not online on line configuration will only take effect can click on the view the current configuration button to view the configured completed ...

Страница 45: ...bar to select DHCP Relay you can set to the DHCP Relay and option82 4 7 1 DHCP Relay In the navigation bar to select DHCP Relay open the DHCP relay function set up and view the relay server IP address and its status as shown Parameter Description Parameter Description ...

Страница 46: ...nly take effect Configuration Example Such as Setting DHCP server IP for 192 168 2 22 4 7 2 Option82 In the navigation bar to select DHCP Relay option82 can set to option82 circuit control proxy remote IP address as shown Parameter Description Parameter Description VLAN id The DHCP request message in the VLAN value range is 1 4094 Circuit control Circuit ID to populate the user custom content scop...

Страница 47: ...DHCP message taken VLAN can bring option82 information Configuration Example Such as Add circuit control proxy remote IP address information 4 8 QOS In the navigation bar to select QOS you can set to the Remark Queue Config and Mapping the Queue 4 8 1 Remark In the navigation bar to select QOS Remark according to the rules for port traffic bag tag or queue map as shown ...

Страница 48: ...hing rules such as choice goal Mac just check the data destination Mac address is in accordance with the rules value Set the value of matching such as choice goal Mac for HH HH HH HH HH HH Choose port to config The application of heavy tag on which interface apply Click on the application of heavy marking rules to take effect Instruction According to the different matching rules to map different p...

Страница 49: ...iption Parameter Description Scheduling strategy Can choose four kinds of modes RR round robin scheduling SP absolute priority scheduling WRR weighted round robin scheduling WFQ weighted fair scheduling WRR weights Set the weights of each queue they will be in proportion to occupy the bandwidth to send data Instruction Queue 7 can not for 0 Configuration Example ...

Страница 50: ...g In the navigation bar to select QOS Mapping the Queue Service class queue mapping service category can be mapped to the corresponding queue as shown Parameter Description Parameter Description Server ID COS the VLAN priority fields 0 to 7 Queue ID Set each cosine value mapping queue number 0 to 7 Configuration Example Such as Cos 3 mapping to the queue 7 set the queue weight 7 to 10 ...

Страница 51: ...o the corresponding service categories as shown Parameter Description Parameter Description Server list DSCP field has seven 0 63 is divided into four tables Queue ID Map the DSCP to COS fields 0 to 7 based on the cosine is mapped to a queue Instruction Cos priority is greater than the DSCP DSCP priority is greater than the port Configuration Example Such as The DSCP value of 3 12 23 mapping to co...

Страница 52: ...apping port can be mapped to the corresponding service categories as shown Parameter Description Parameter Description Port Select the port number 1 26 Service ID Mapped to the service ID and then according to the service ID into the queue Instruction Cos priority is greater than the DSCP DSCP priority is greater than the port Configuration Example ...

Страница 53: ... 24PoE User Manual 52 Such as Port 4 5 6 respectively cos4 cos5 cos6 4 9 Address Table In the navigation bar to select Address Table you can set to MAC add and delete MAC study and Aging and MAC address filtering ...

Страница 54: ... Description Parameter Description Clear Mac Can choose to clear the multicast Mac address clear dynamic unicast Mac address clear static unicast Mac address clear the specified Mac address Mac address table VLAN Fill in the need to add or delete VLAN id not create vlans to create can only take effect Instruction According to different conditions to clear Mac address view add learn the Mac address...

Страница 55: ... the navigation bar to select Address Table Mac study and Aging can be set up port Mac address study limit and Mac address aging time as shown Parameter Description Parameter Description Mac address Range 0 8191 default 8191 Mac address study limit Default 300 Configuration Example Such as 1 Setting port 5 6 7 8 address study limit for 2000 ...

Страница 56: ... address filtering In the navigation bar to select Address Table Mac address Filtering can be filtered according to the condition does not need the Mac address as shown Parameter Description Parameter Description Mac address Can not add multicast Mac address VLAN VLAN number Configuration Example Such as The Mac address for 00 20 15 09 12 12 added to the filter in the table ...

Страница 57: ... Config and RMON Config 4 10 1 SNMP Config 4 10 1 1 SNMP Config In the navigation bar to select SNMP SNMP Config you can SNMP function enable as shown Instruction The SNMP function must be turned on in the configuration RMON otherwise it will be configured to fail Configuration Example Such as Open SNMP ...

Страница 58: ...ication between the password Access authority Read only specify the NMS SNMP host of MIB variables can only be read cannot be modified Read only can write specify the NMS SNMP host of MIB variables can only read can also be modified Instruction The upper limit of the number of groups is 8 Configuration Example Such as Add a read write group called public 4 10 1 3 Group Config In the navigation bar...

Страница 59: ...ion also does not need to be kept secret Both authentication and encryption This group of users need to verify the news of transmission and transmission of data need to be kept secret Read view read and write view study view The associated view name Instruction Before the cap on the number set of configuration of 8 the new group needs a new view to create a group Configuration Example Such as Firs...

Страница 60: ... and transmission of data need to be kept secret Authentication mode Specified use MD5 authentication protocol or SHA authentication protocol Authentication password Range 8 10 Encrypt mode Specified using AES encryption protocol or DES encryption protocol Group name A user group name Encrypt password Range 8 60 Instruction Cap on the number configuration of 8 users need a new view and group to us...

Страница 61: ...curity mode Specified using AES encryption protocol or DES encryption protocol Group name User group name Instruction The Trap cap on the number configuration of 8 you can configure a number of different SNMP Trap host used to receive messages Trigger the trap message time Port Linkup Linkdown equipment of cold start restart when power supply drop warm start a warm restart and RMON set port statis...

Страница 62: ...iption View name View mane Include Indicate the MIB object number contained within the view Exclude Indicate the MIB object son number was left out of view MIB subtree OID View the associated MIB object is a number of MIB Subtree mask MIB OID mask Instruction Each view is best to configure a view rule otherwise it will affect the SNMP function Configuration Example Such as Establish a view 123 MIB...

Страница 63: ...Parameter Description Index The index number the value range of statistical information table is 1 65535 Interface mane To monitor the source port Ower Set the table creator range 1 30 characters of a string Instruction At the time of configuration RMON SNMP functions must be open otherwise the prompt dialog box will appear Configuration Example Such as Set up monitoring Ethernet port after 4 to c...

Страница 64: ... Historical control table item index number value range is 1 65535 Interface name To record the Ethernet interface Maximum number of samples Set the history control table item of the corresponding table capacity namely the Max for number of records the history table value range is 1 65535 Sample period Set up the statistical period scope for 5 3600 the unit is in seconds owner Set the table creato...

Страница 65: ...er value range is 1 65535 Static table Statistical type values 3 DropEvents 4 Octets 5 Pkts 6 BroadcastPkts 7 MulticastPkts 8 CRCAlignErrors 9 UndersizePkts 10 OversizePkts 11 Fragments 12 Jabbers 12 Collisions 14 Pkts64Octets 15 Pkts65to127Octets 16 Pkts128to255Octets 17 Pkts256to511Octets 18 Pkts512to1023Octets 19 Pkts1024to1518Octets Statistical index Set up the corresponding statistics statist...

Страница 66: ... threshold limit of events Upper lower limit reached for each event Owner Set the table creator ownername for 1 30 characters of a string Instruction At the time of configuration RMON SNMP functions must be open otherwise the prompt dialog box will appear This configuration need to configure statistics groups and events Configuration Example Such as New statistics group of 77 and the event group 3...

Страница 67: ...d the system will log Owner Set the table creator ownername for 1 30 characters of a string Instruction At the time of configuration RMON SNMP functions must be open otherwise the prompt dialog box will appear Configuration Example Such as Create an event to trigger 345 the system sends the trap message and log 4 11 System In the navigation bar to select System you can set to the System Config Sys...

Страница 68: ...h as shown Parameter Description Parameter Description Device name Switch name Manage VLAN Switches use VLAN management Manage ip Switch IP address management Timeout Don t use more than login timeout after login to log in again Configuration Example Such as 1 Set up the VLAN 2 is management VLAN should first created VLAN 2 the VLAN Settings and set a free port in the VLAN 2 ...

Страница 69: ...026G 2GS 24PoE User Manual 68 2 Insert the PC interface 9 or 10 ports set up the management IP for 192 168 2 12 device name is yoyo timeout for 20 minutes 3 Use 192 168 1 12 logging in sets the system time ...

Страница 70: ... System Config System restart equipment can be restarted as shown Instruction Click the button to restart the switch The restart process may take 1 minute Please wait patiently The page will be refreshed automatically after device restart Configuration Example Such as Click restart button ...

Страница 71: ...ion 1 If you set a new Web login password then log in again after seting the new password 2 Password can not contain Chinese full width characters question marks and spaces 3 If forget the password reset can be reset in the console switch config password admin New Password 3456 Confirm Password 3456 Configuration Example Such as Amend the password to 1234 ...

Страница 72: ...ure the user through the SSH login device to be turned on to enable the switch Configuration Example Such as the SSH open CRT can be used to log on 4 11 1 5 Telnet login In the navigation bar to select System Config Telnet login equipment can be restarted as shown Instruction Configure the user through the Telnet login device to be turned on to enable the switch ...

Страница 73: ...iew the log and set up the log server as shown Parameter Description Parameter Description Log switch Open and close Server IP Appoint to server address Send log level 0 7 key Enter the required query of characters Instruction Open log switch set up the syslog server system log will automatically be pushed to the server Configuration Example Such as 1 The error log information in 192 168 1 3 pushe...

Страница 74: ...ut the Mac keywords click query button click on the clear log button can clear the log 4 11 2 System Upgrade In the navigation bar to select System System Upgrade Optional upgrade file to upgrade as shown Such as select the file to upgrade ...

Страница 75: ...unter flash to make the page is temporarily unable to respond to the page this time can not power off or restart the device until prompted to upgrade successfully 4 11 3 Config Management 4 11 3 1 Current configuration In the navigation bar to select System Config Management Current configuration can import and export configuration files the backup file as shown ...

Страница 76: ...roduction of configuration to enable the new configuration please in this page Restart device Otherwise configuration does not take effect Configuration Example Such as 1 In the configuration first save the page click save configuration to save the current configuration then export the configuration 2 import configuration 3 backup ...

Страница 77: ...up file as shown Instruction Operating this page should be in the current configuration page first the backup file Configuration Example Such as Restore backup 4 11 3 3 Restore factory configuration In the navigation bar to select System Config Management Restore factory configuration can export the current configuration and restore factory configuration as shown ...

Страница 78: ...useful configuration the current system can lead the factory configuration again after the current configuration Configuration Example Such as Restore configuration can be the guide before they leave the current configuration 4 11 4 Config Save In the navigation bar to select System Config Save you can save current configuration as shown ...

Страница 79: ...ator Privileges In the navigation bar to select System Administrator Privileges configurable ordinary users as shown Instruction Only the admin of the super administrator can access this page is used to manage users and visitors The user can log in the Web management system of equipment for routine maintenance In addition to the admin and user can add up to five users Ordinary users can only acces...

Страница 80: ... Info Collect In the navigation bar to select System Info Collect you can collect to the system debug information as shown Instruction Collect useful information it may take a few moment Configuration Example Such as Click on collect button ...

Страница 81: ...x 100 1000Mbps SFP ports 1x Console port Transfer Method Store and Forward Switching Capacity 52G MAC Address Learning 8K Packet Forwarding Rate 38 69Mpps Packet Buffer 4 1Mbit Jumbo Frame 9216Bytes PoE Ports RJ45 24 PoE ports compliant with 802 3at af PoE Budget 380W Power Pin Assignment 1 2 3 6 Indicators Per Device Power System Per Port Link Activity Speed PoE Frame Filtering and Forward Rate 1...

Страница 82: ...trust port Static routing capacity Ping and Traceroute The security policy ACE capacity ACL QoS DAI VLAN Port based VLAN 802 1Q VLAN Safety features Radius Tacacs Preventing DOS attacks dot1x The gateway ARP deception Application protocol DHCP Relay DHCP snooping DHCP Client FTP TFTP Management HTTP WEB Telnet SSH Console Other function LLDP IGMP Snooping SNMPV1 V2c V3 RMON 1 2 3 9 POE Management ...

Отзывы: