CLI user manual
Page13
Serial(COM2)#
set UDP 1 1 55555 0 192.168.1.55 44444 0
[OK]
Example:
Configuration
“
session: 1, local port: 3333, diable DNS, IP address: 192.168.17.11, destination port:
2222, connection mode: link now, heartbeat time: 0, Timeout: 20s, virtual COM port disable”, enter the bold
type command as follows and enter return key:
Serial(COM2)#
set tCP_C 1 1 33333 0 192.168.17.11 22222 1 0 20 0
[OK]
Example:
COM2 in advanced mode, configuration working mode: TCP server, session: 4, enter the bold type
command as follows and enter return key:
Serial(COM2)#
SET session_multi 1 4
[OK]
Example:
COM2 in advanced mode, configuration destination port:2000, heart time: 0s, timeout: 30s, Virtual
COM port disable, enter the bold type command as follows and enter return key:
Serial(COM2)#
set TCP_S_multi 2000 0 30 0
[OK]
Example:
COM2 in advanced mode, session: 1, destination: 1000, DNS disable, IP address from 192.168.17.11
to 192.168.17.254, destination port: 2000, virtual COM port disable, enter the bold type command as follows and
enter return key:Serial(COM2)#
set UDP_multi 1 1000 0 192.168.17.11 192.168.17.254 2000 0
[OK]