Connected network cable and switch port keep invariant, change other
computers;
-
Connected network cable and computer keep invariant, change other
switch port;
-
If the switch port faults are confirmed, please contact supplier for
maintenance.
2.
How about the order of port self-adaption state detection?
The port self-adaption state detection is conducted according to following order:
1000Mbps full duplex, 100Mbps full duplex, 100Mbps half-duplex, 10Mbps full
duplex, 10Mbps half-duplex, detect in order from high to low, connect
automatically in supported highest speed.
5.3 Indicator Problem
1.
Power indicator isn't bright, what's the reason?
Possible reasons include:
-
Not connected to the power socket; troubleshooting, connected to the
power socket.
-
Power supply or indicators faults; troubleshooting, change the power
supply or device test.
-
Power supply voltage can't meet the device requirements; troubleshooting,
configure the power supply voltage according to the device manual.
2.
Link/Act indicator isn't bright, what's the reason?
Possible reasons include:
-
The network cable portion of Ethernet copper port is disconnected or bad
contact; troubleshooting, connect the network cable again.
-
Ethernet terminal device or network card works abnormally; troubleshooting,
eliminate the terminal device fault.
-
Not connected to the power socket; troubleshooting, connected to the
power socket.
-
Interface rate doesn't match the pattern; troubleshooting, examine whether
the device transmission speed matches the duplex mode.