background image

- 3 - 

 

10/100Base-T(X) MDI-X (Cross over cable) 

 

Gigabit MDI (straight-through cable) 

 

Gigabit MDI-X (Cross over cable) 

 

MDI/MDI-X  auto  connection  makes  switch  easy  to  use  for 

customers without considering the type of network cable.

 

1000Base SFP fiber port(mini-GBIC) 

1000Base-X  SFP  fiber  port  adopts  Gigabit  mini-GBIC 

transmission, can choice different SFP module according to 

different transfer distance. Fiber interface must use for pair, 

TX port is transmit side, must connect to RX (receive side). 

The fiber interface support loss line indicator. 

Suppose

: If you make your own cable, we suggest labeling 

the  two  sides  of  the  same  line  with  the  same  letter  (A-to-A 

and B-to-B, shown as below, or A1-to-A2 and B1-to-B2). 

 

LED Indicator

 

LED indictor light on the front panel of product, the function 

of each LED is described in the table as below. 

System indication LED 

LED 

State 

Description 

P1 

ON 

Power is being supplied to 

power input PWR1 

OFF 

Power is 

not 

being supplied to 

power input PWR1 

P2 

ON 

Power is being supplied to 

power input PWR2 

OFF 

Power is 

not 

being supplied to 

power input PWR2 

Alarm 

ON 

When the alarm is enabled, 

power or the port’s link is 

inactive. 

OFF 

Power and the port’s link is 

active, the alarm is disabled. 

Run 

ON/OFF 

System is not running well 

Blinking 

System is running well 

Link/ACT 

(G1~G20) 

ON 

Port connection is active 

Blinking 

Data transmitted 

OFF 

Port connection is not active 

Installation

 

Before installation, confirm that the work environment meet 

the  installation  require,  including  the  power  needs  and 

abundant  space.  Whether  it  is  close  to  the  connection 

equipment and other equipments are prepared or not.   

1.  Avoid  in  the  sunshine,  keep  away  from  the  heat 

fountainhead or the area where in intense EMI. 

2.  Examine  the  cables  and  plugs  that  installation 

requirements. 

3.  Examine whether the cables be seemly or not (less than 

100m) according to reasonable scheme.   

4.  Power: support 48VDC power supply 

5.  Environment: working temperature: -40

75

 

Storage Temperature: -40

85

 

Relative humidity 5%

95% 

 

DIN Rail Installation 

In  order  to  use  in  industrial  environments  expediently,  the 

product  adopt  35mm  DIN-Rail  installation,  the  installation 

steps as below: 

1. Examine the DIN-Rail attachment 

2. Examine  DIN  Rail  whether  be  firm  and  the  position  is 

suitability or not. 

3. Insert the top of the DIN-Rail into the slot just below the 

stiff metal spring. 

4. The  DIN-Rail  attachment  unit  will  snap  into  place  as 

shown below. 

Wiring Requirements 

Cable laying need to meet the following requirements:

 

Содержание IES7120G-4GS

Страница 1: ...lution of the economy Packing list The industrial Ethernet switch is shipped with the following items If any of these items are missing or damaged please contact your customer service representative for assistance Industrial Ethernet switch 1 Documentation and software CD 1 User manual 1 DIN Rail mounting kit 1 Warranty card 1 Feature Support IEEE802 3 IEEE802 3u IEEE802 3z ab IEEE802 3x IEEE802 1...

Страница 2: ...hange the status of DIP switch Relay connection Relay access terminals in the top panel of the device Between the two terminal relay as an open circuit state in normal non alarm state when there is any alarm information to the closed state The two terminal block connector are used to detect both power failure and port failure The two wires attached to the Fault contacts form an open circuit when t...

Страница 3: ...nactive OFF Power and the port s link is active the alarm is disabled Run ON OFF System is not running well Blinking System is running well Link ACT G1 G20 ON Port connection is active Blinking Data transmitted OFF Port connection is not active Installation Before installation confirm that the work environment meet the installation require including the power needs and abundant space Whether it is...

Страница 4: ...ress flow control Function Switch function SW Ring QOS 802 1QVLAN RSTP MSTP LLDP LACP ACL ROMN GMRP IGMP Snooping SNMP Port trunking static multicast filter port mirroring bandwidth management broadcast storm control port flow statistics upgrade online up and download configuration file user name access system SW Ring Support Single Couple Chain Dual homing Exchange attribute 100M forward speed 14...

Отзывы: