3onedata IES618-4D Series Скачать руководство пользователя страница 2

15. 

RS-485 interface 

Mounting Dimension

 

Unit: mm 

 

Attention before mounting:

 

 

Don't place or install the device in area near water or 

moist, keep the relative humidity of the device 

surrounding between 5%~95% without condensation. 

 

Before power on, first confirm the supported power 

supply specification to avoid over-voltage damaging the 

device. 

 

The device surface temperature is high after running; 

please don't directly contact to avoid scalding. 

DIN-Rail Mounting

 

For convenient usage in industrial environments, the product 

adopts 35mm DIN-Rail mounting, mounting steps as below: 

 

 

Check  whether  the  DIN-Rail  mounting  kit  that 

Step 1

comes with the device is installed firmly. 

 

Insert the bottom of DIN-Rail mounting kit (one side 

Step 2

with  spring  support)  into  DIN-Rail,  and  then  insert 

the top into DIN-Rail. 

Tips: 

Insert a little to the bottom, lift upward and then insert 

to the top. 

 

Check and confirm the product is firmly installed on 

Step 3

DIN-Rail, and then mounting ends. 

Disassembling DIN-Rail

 

 

Power off the device. 

Step 1

 

After lift the device upward slightly, first shift out the 

Step 2

top of DIN-Rail mounting kit, and then shift out the 

bottom of DIN-Rail, disassembling ends. 

Attention before powering on: 

 

Power ON operation: first connect power line to the 

connection terminal of device power supply, and then 

power on. 

 

Power OFF operation: first unpin the power plug, and 

then remove the power line, please note the operation 

order above. 

Power Supply Connection

 

This  series  provide  4-pin  7.62mm  pitch 

input 

terminal 

blocks, 

and 

two 

independent DC power supply systems of 

P1 and P2. It could be used individually or 

connecting  to  two  independent  DC  power  supply  systems 

externally.  The  power  supply  supports  non-polarity  and 

anti-reverse  connection,  which  could  still  work  after  reverse 

connection. 

Input voltage of power supply: 12VDC

48VDC 

Relay Connection

 

This  series  provide  2-pin  7.62mm  pitch  input 

terminal  blocks.  Relay  terminal  blocks  are  a 

pair  of  normally  open  contacts  in  the  alarm 

relay of the device. They are open circuit in the 

status  of  normal  no  alarm,  and  closed  when  any  warning 

message occurs. For example: they are closed and send out 

alarm when power off. The product supports 1 relay warning 

message  output,  and  warning  messages  output  of  the  DC 

power  supply  or  network  abnormal  alarm  output.  It  can  be 

connected to alarm indicator, alarm buzzer, or other switching 

value  collecting  devices  for  timely  warning  operating  staffs 

when the warning message occurs. 

DIP Switch Settings

 

The  products  provide  4  pins  DIP  switch  for 

function  settings,  where  "ON"  is  the  enable  valid 

terminal.  Please  power  off  and  power  on  after 

changing the DIP switch status. 

DIP switches definitions as follows: 

DIP 

Definition 

Operation 

Reserved 

Upgrade 

Set the DIP switch to ON, the device 

can conduct program upgrade, set it 

back when upgrade is finished 

Restore 

factory 

defaults 

Set the DIP switch to ON, power on 

the device again and it will restore 

factory defaults, and then set it back. 

Reserved 

Serial Port Connection

 

 

RS-232 

This  device  provides  RS-232  ports,  whose 

interface  type  is  DB9  male  head.  Its  pin 

definitions display as the table below. 

PIN 

RS-232 

DCD

 

RxD

 

TxD

 

DTR

 

GND

 

DSR

 

RTS

 

CTS

 

 

RS-485/422 

This series Model IV, Model V and Model 

VI provide 5-pin RS-485/422 serial port of 

industrial  terminal.  Its  pin  definitions 

display as the table below. 

PIN 

RS-422 

T+ 

T- 

GND 

R+ 

R- 

RS-485 

D+ 

D- 

— 

— 

— 

Содержание IES618-4D Series

Страница 1: ...orts 4 RS 232 Interfaces Model II IES618 2F 4D RS 232 6 100M Copper Ports 2 100M Fiber Ports 4 RS 232 Interfaces Model III IES618 4F 4D RS 232 4 100M Copper Ports 4 100M Fiber Ports 4 RS 232 Interfaces Model IV IES618 4DI RS 485 8 100M Copper Ports 4 RS 485 Interfaces Model V IES618 2F 4DI RS 485 6 100M Copper Ports 2 100M Fiber Ports 4 RS 485 Interfaces Model VI IES618 4F 4DI RS 485 4100M Copper ...

Страница 2: ...ually or connecting to two independent DC power supply systems externally The power supply supports non polarity and anti reverse connection which could still work after reverse connection Input voltage of power supply 12VDC 48VDC Relay Connection This series provide 2 pin 7 62mm pitch input terminal blocks Relay terminal blocks are a pair of normally open contacts in the alarm relay of the device...

Страница 3: ...hem can be mutually accessed Enter device s IP address in the address bar of the Step 2 computer browser Enter device s username and password in the login Step 3 window as shown below Click OK button to login to the WEB interface of Step 4 the device Note The default IP address of the device is 192 168 1 254 The default username and password of the device is admin If the username or password is lo...

Страница 4: ...VDC Model IV No load 1 80W 24VDC Full load 3 90W 24VDC Model V No load 3 58W 24VDC Full load 5 35W 24VDC Model VI No load 4 80W 24VDC Full load 6 90W 24VDC Environmental Limits Working temperature 40 75 Storage temperature 40 85 Working humidity 5 95 no condensation Protection grade IP40 metal shell ...

Отзывы: