background image

OFF 

Ethernet port connection has not 

established valid network connection. 

TX 

(1-2) 

OFF 

No data or abnormal data is being 

transmitted through serial port 

Blinking 

Serial port is transmitting data 

RX 

(1-2) 

OFF 

No data or abnormal data is being 

received through serial port 

Blinking 

Serial port is receiving data 

Logging in to WEB Interface

 

This  device  supports  WEB  management  and  configuration. 

Computer  can  access  the  device  via  Ethernet  interface.  The 

way  of  logging  in  to  device

’s  configuration  interface  via  IE 

browser is shown as below: 

 

Configure  the  IP  addresses  of  computer  and  the 

Step 1

device  to  the  same  network  segment,  and  the 

network between them can be mutually accessed. 

 

Enter device

’s IP address in the address bar of the 

Step 2

computer browser. 

 

 

Enter device

’s username and password in the login 

Step 3

window as shown below. 

 

 

Click 

“OK” button to login to the WEB interface of 

Step 4

the device. 

Note: 

 

The default IP address of the device is “192.168.1.254”. 

 

The  default  username  and  password  of  the  device  is 

“admin”. 

 

If the username or password is lost, user can restore it to 

factory  settings  via  device  DIP  switch  or  management 

software;  all  modified  configurations  will  be  cleared 

after  restoring  to  factory  settings,  so  please  backup 

configuration file in advance. 

 

Please  refer  to  user  manual  for  specific  configuration 

method  of  logging  in  to  WEB  interface  and  other 

configurations about network management function. 

Specification

 

Panel 

 

100M copper port

 

10/100Base-T(X)

 

self-adapting 

RJ45 

port, 

full/half  duplex  self-adaption 

or  specified  operating  mode, 

support 

MDI/MDI-X 

self-adaption

 

100M fiber port 

100Base-FX, support 

SC/ST/FC interface 

RS-232 serial port 

DB9 male connector, 

electrostatic protection 15kV 

RS-485/422 serial port 

5-pin 5.08mm pitch terminal 

block, isolation voltage 2kV, 

electrostatic protection 15kV 

Alarm interface

 

2-core  7.62mm  pitch  terminal 

block,  support  1  relay  alarm 

information  output,  current 

loading  capability  1A/24VDC, 

0.5A/120VAC

 

Indicator 

Power indicator, running 

indicator, interface indicator, 

alarm indicator and serial port 

transmission indicator 

Switch property

 

 

Backplane bandwidth

 

1.2G

 

Packet buffer size

 

0.5Mbit

 

MAC table size

 

2K

 

Power supply

 

 

Input power supply

 

DC power supply products 

12~48VDC 

Support dual power supply 

redundancy, nonpolarity, and 

anti-reverse connection 

Support built-in overcurrent 

3.0A protection 

Access terminal 

4 pins 7.62mm pitch terminal 

blocks

 

Consumption 

 

IES615-2D (RS-232) 

No-load: 0.84W@24VDC 

Full-load: 1.54W@24VDC

 

IES615-1F-2D (RS-232) 

No-load: 1.80W@24VDC 

Full-load: 2.40W@24VDC

 

IES615-2F-2D (RS-232) 

No-load: 2.50W@24VDC 

Full-load: 3.00W@24VDC

 

IES615-2DI (RS-485) 

No-load: 1.22W@24VDC 

Full-load: 1.90W@24VDC 

IES615-1F-2DI (RS-485) 

No-load: 2.10W@24VDC 

Full-load: 2.60W@24VDC 

IES615-2F-2DI (RS-485) 

No-load: 3.00W@24VDC 

Full-load: 3.50W@24VDC 

Environmental Limits 

 

Working temperature

 

-40

75

 

Storage temperature

 

-40

85

 

Working humidity

 

5%

95% (no condensation) 

Protection grade 