3onedata IES605-2D series Скачать руководство пользователя страница 8

configure

OFF is default factory

,1 and 2 keep for future function.

3 is for upgrade. 4 is recovery default factory. Please power off

and power on when you change the status of DIP switch.

Communication connector

10/100BaseT(X) Ethernet port

The pinout of RJ45 port display as below, connect by UTP or

STP. The connect distance is no more than 100m. 100Mbps is

used 120

Ω

of UTP 5 , 10Mbps is used 120

Ω

of UTP 3,4,5.

RJ 45 port support automatic MDI/MDI-X operation. can

connect the PC, Server, Converter and HUB .Pin 1,2,3,6

Corresponding connection in MDI. 1→3, 2→6, 3→1, 6→2 are

used as cross wiring in the MDI-X port of Converter and HUB.

10Base-T/100Base-TX are used in MDI/MDI-X, the define of Pin

in the table as below.

NO.

MDI signal

MDI-X signal

1

TX+

RX+

2

TX-

RX-

3

RX+

TX+

6

RX-

TX-

4, 5, 7, 8

Note

TX

±”

Transmit Data

±,

RX

±”

Receive Data

±,

“—”

Not Use

MDI (straight-through cable)

1

8

Содержание IES605-2D series

Страница 1: ...IES605 2D series Industrial Ethernet switch User manual Shenzhen 3onedata Technology Co Ltd Tel 86 755 26702668 Fax 86 755 26703485 www 3onedata com ...

Страница 2: ...C Support 3 port is 10 100BaseT X Ethernet 2 port is 100BaseFX fiber port and 2 port RS 232 6 IES605 2F 2DI RS 485 P 12 48VDC Support 3 port is 10 100BaseT X Ethernet 2 port is 100BaseFX fiber port and 2 port RS 485 422 it adopted SW Ring redundant technology Recovery time 20ms users can set the redundant easily to increase network reliability furthermore It adopted no fan low power consumption de...

Страница 3: ...2 port RS 232 RS 485 RS 422 serial device server Support based on socket application access Support Sever Client UDP based mode and Sever UDP advanced mode Support TCP UDP ARP and DHCP protocol Support Web management Support 2K MAC address table Support 2 power supply input and 1 relay alarm output Support port line and redundant network faulty unusual local and remote alarm High strength iron she...

Страница 4: ...lay output terminal block 4 DIP switch 4 bits 5 DIN Rail 6 LED indicator 7 10 100Base TX RJ45 port 8 RS 232 port IES605 2DI RS 485 P 12 48VDC 1 PWR1 PWR2 power supply 2 Ground screw 3 Relay output terminal block 4 DIP switch 4 bits 5 DIN Rail 6 LED indicator 7 10 100Base TX RJ45 port 8 RS 485 422 port ...

Страница 5: ... 10 100Base TX RJ45 port IES605 1F 2DI RS 485 P 12 48VDC 1 PWR1 PWR2 power supply 2 Ground screw 3 Relay output terminal block 4 DIP switch 4 bits 5 DIN Rail 6 LED indicator 7 100Base FX fiber port 8 RS 485 422 port 9 10 100Base TX RJ45 port IES605 2F 2D RS 232 P 12 48VDC 1 PWR1 PWR2 power supply 2 Ground screw 3 Relay output terminal block 4 DIP switch 4 bits 5 DIN Rail 6 LED indicator ...

Страница 6: ...S605 2F 2DI RS 485 P 12 48VDC 1 PWR1 PWR2 power supply 2 Ground screw 3 Relay output terminal block 4 DIP switch 4 bits 5 DIN Rail 6 LED indicator 7 100Base FX fiber port 8 RS 485 422 port 9 10 100Base TX RJ45 port Appearance and dimension Unit mm Front view Back view ...

Страница 7: ...e at the same time If one of the power system broke the device can work un interruptible built in over current protection Reverse connection protection Relay connection Vertical view Top view The relay owns two contacts of the terminal block on the top panel of IES605 2D series It is used to detect both power failure and port failure The two wires attached to contacts form an open circuit when 1 I...

Страница 8: ...s no more than 100m 100Mbps is used 120Ωof UTP 5 10Mbps is used 120Ωof UTP 3 4 5 RJ 45 port support automatic MDI MDI X operation can connect the PC Server Converter and HUB Pin 1 2 3 6 Corresponding connection in MDI 1 3 2 6 3 1 6 2 are used as cross wiring in the MDI X port of Converter and HUB 10Base T 100Base TX are used in MDI MDI X the define of Pin in the table as below NO MDI signal MDI X ...

Страница 9: ...port must be used in pair TX transmit port connect remote switch s RX receive port RX receive port connect remote switch s TX transmit port The optical fiber connection supports the line to instruct enhance the reliability of network effectively Suppose If you make your own cable we suggest labeling the two sides of the same line with the same letter A to A and B to B shown as below or A1 to A2 an...

Страница 10: ...ND 6 DSR 7 RTS 8 CTS 9 DB9 male RS 232 RS 485 422 port PIN RS 422 RS 485 1 T D 2 T D 3 GND 4 R 5 R RS 485 422 LED indicator IES605 2D series LED indicator light on the front panel the function of each LED is described in the table as below ...

Страница 11: ...tion Blinking Network in activity status OFF Did not establish effective network connection TX Blinking Transmit data unwonted OFF Transmit data wonted RX Blinking Receive data unwonted OFF Receive data wonted Installation Before installation confirm that the work environment meet the installation require including the power needs and abundant space Whether it is close to the connection equipment ...

Страница 12: ...DIN Rail attachment 2 Examine DIN Rail whether be firm and the position be suitability or not 3 Insert the top of the DIN Rail into the slot just below the stiff metal spring 4 The DIN Rail attachment unit will snap into place as shown below Wiring Requirements Cable laying need to meet the following requirements 1 It is needed to check whether the type quantity and specification of cable match th...

Страница 13: ...er cable but structure in the middle of alignment rack 8 Pigtail cannot be tied and swerved as less as possible Swerving radius cannot be too small small swerving causes terrible loss of link Its banding should be moderate not too tight and should be separated from other cables 9 It should have corresponding simple signal at both sides of the cable for maintaining Specification Technology Standard...

Страница 14: ...ogy auto detect and control data transfer direction Loading RS 485 422 side support 32 nodes loop back Protection 2KV isolation 15KV static protection Connector RS232 DB9 male RS485 4225 bit terminal block Transfer distance Twisted cable 100m CAT5 CAT5e Multi mode fiber 1310nm 2 5Km Single mode fiber 1310nm 20 40 60Km 1550nm 80 100 120Km RS 485 422 1200m RS 232 15m Exchange attribute 100M transmit...

Страница 15: ...ption 1 9 W 24VDC IES605 1F 2D RS 232 P 12 48VDC None load consumption 1 5W 24VDC Full load consumption 2W 24VDC IES605 1F 2DI RS 485 P 12 48VDC None load consumption 1 7W 24VDC Full load consumption 2 4W 24VDC IES605 2F 2D RS 232 P 12 48VDC None load consumption 2 2W 24VDC Full load consumption 2 3W 24VDC IES605 2F 2DI RS 485 P 12 48VDC None load consumption 2 4W 24VDC Full load consumption 2 7W ...

Страница 16: ...95 non condensing Standard EMI FCC Part 15 CISPR EN55022 class A EMS EN61000 4 2 ESD Level 4 EN61000 4 3 RS Level 3 EN61000 4 4 EFT Level 4 EN61000 4 5 Surge Level 4 EN61000 4 6 CS Level 3 EN61000 4 8 PFM Level 5 Shock IEC 60068 2 27 Free fall IEC 60068 2 32 Vibration IEC 60068 2 6 Certification CE FCC RoHS UL508 Pending Warranty Warranty time 5 years ...