3onedata IES5028G Series Скачать руководство пользователя страница 3

- 3 - 

”not use. 

10/100Base-T(X) MDI (straight-through cable) 

 

10/100Base-T(X) MDI-X (Cross over cable) 

 

Gigabit MDI (straight-through cable) 

 

Gigabit MDI-X (Cross over cable) 

 

MDI/MDI-X auto connection makes switch easy to use for 

customers without considering the type of network cable.

 

1000Base SFP fiber port 

1000BaseSFP  optical fiber interface is used  SFP optical module 
communication through optical fiber transmission, can choice 
different SFP module according to different transfer distance. 
Fiber interface must use for pair, TX port is transmit side, must 
connect to RX (receive side). The fiber interface support loss line 
indicator. 

Suppose

:  If you make your own cable, we suggest  labeling  the 

two sides of the same line with the same letter (A-to-A and 
B-to-B, shown as below, or A1-to-A2 and B1-to-B2). 

   

 

LED Indicator

 

LED indictor light on the front panel of product, the function of 
each LED is described in the table as below. 

System Indication LED 

LED 

State   

Description 

PWR 

(P1~P2) 

ON 

Power is being supplied to 
power input PWR input 

OFF 

Power is 

not

 being supplied 

to power input PWR input 

RUN 

ON/OFF  System is not running well 
Blinking  System is running well 

Alarm 

ON 

When the alarm is enabled, 
power or the port’s link is 
inactive. 

OFF 

Power and the port’s link is 
active, the alarm is disabled. 

Link/ACT 

(1~28) 

ON 

Port connection is active 

Blinking  Data transmitted 
OFF 

Port connection is not active 

Installation

 

Before installation, confirm that the work environment meet the 
installation require, including the power needs and abundant 
space. Whether it is close to the connection equipment and other 
equipments are prepared or not.   
1. Avoid in the sunshine, keep away from the heat fountainhead or 

the area where in intense EMI. 

2. Examine the cables and plugs that installation requirements. 
3. Examine whether the cables be seemly or not (less than 100m) 

according to reasonable scheme.   

4. Power: 100-240VAC power input 
5. Environment: working temperature: -40

75

 

Storage Temperature: -40

85

 

Relative humidity 5%

95% 

Rack mount installation 

In most of industrial application, it is convenience to use rack 
mount installation, the step of installation is as follows: 
1.

 

Check if have rack mount installation tools and components 
(The package provided parts of components) 

2.

 

Check installation place strong or not, have the place to install 
the device or not. 

3.

 

Put the device into rack, aim at the screw hole of device and 
rack, fixed it in strong screw. Easy and convenience to 
operation. 

Wiring Requirements 

Cable laying need to meet the following requirements,

 

1.

 

It is needed to check whether the type, quantity and 
specification of cable match the requirement before cable 
laying; 

2.

 

It is needed to check the cable is damaged or not, factory 
records and quality assurance booklet before cable laying; 

3.

 

The required cable specification, quantity, direction and 
laying position need to match construction requirements, and 
cable length depends on actual position; 