Step 1 Select the device mounting position and ensure

enough mounting size is reserved.

Step 2 Adopt 4 bolts to install the mounting lugs in the

device position as figure below.

Step 3 Place the device in the rack; adopt 4 bolts to fix two

sides mounting lugs in the rack.

Step 4 Check and confirm the product is firmly installed on

the rack, then mounting ends.

Disassembling Device

Step 1 Power off device.
Step 2 Adopt screw driver to loosen the 4 bolts fixed on

the mounting lugs in the rack.

Step 3 Remove the device away from the rack,

disassembling ends.

Note before powering on:

Power ON operation: First insert the power supply terminal
block into the device power supply interface, and then plug
the power supply socket and power on.

Power switch “—” means power ON, “O” means power OFF.

Power OFF operation: First, put the powers switch to the "O"
side and then disconnect the power supply. Finally disconnect

the connector between the device and the power cord. Please
notice the operation order above.

Power Supply Connection

AC power supply

This device provides 2 AC power supply
access interfaces which come with a switch.
The

power

supply

input

range

is

100~240VAC/DC.

DC power supply

This device provides 2 DC power
supplies which are 5-pin 5.08mm pitch
terminal blocks.The power supply

occupies 3 pins and supports anti-reverse connection.
Power supply range: 36~72VDC

Restoring Default Settings

RESET is restoring default settings button. Restoring default
settings steps as follows: Press and hold the RESET button,
disconnect the power supply and then power on the device,
wait for about 3~4 seconds to restore the factory settings.

Relay Connection

R+ and R- are the relay alarm output
section. They are open circuit in normal
non alarm state, closed when any
alarm information occurs. The product

supports 2-way relay alarm output, externally connected to
alarm lights or alarm buzzer or other switching value
collecting device in order to timely notify operators when the
alarm occurs.

Console Port Connection

The series products provide 1 program debugging port
based on RS-232 serial port which can conduct device CLI
command management after connecting to PC. It adopts
RJ45 interface, its pin definition is showed as follows:

Pin No.

2

3

5

Definition

TXD

RXD

GND

Checking LED Indicator

The series products provide LED indicators to monitor the
device working status with a comprehensive simplified
troubleshooting; the function of each LED is described in the
table as below:

LED

State

Description

P1

ON

Power supply is connected or
running normally

OFF

Power supply is disconnected or
running abnormally

P2

ON

Power supply is connected or
running normally

OFF

Power supply is disconnected or
running abnormally

RUN

Blinking System is running normally
OFF

System is not running or running
abnormally

ON

System is running abnormally

ALM

ON

Power supply or the port’s link is
alarming.

OFF

Power and the port’s link exist no
alarm

Link
(G1-G28)

ON

Port connection is active

Blinking Data transmitted
OFF

Port connection is not active

Logging in to WEB Interface

This device supports WEB management and configuration.
Computer can access the device via Ethernet interface. The
way of logging in to device’s configuration interface via IE
browser is shown as below:
Step 1

Configure the IP addresses of computer and the
device to the same network segment, and the

network between them can be mutually
accessed.

Step 2

Enter device’s IP address in the address bar of

Отзывы: