3onedata IES5024 Series Скачать руководство пользователя страница 3

Definition of RJ45 pins as follows: 

Restore Factory Defaults

 

Steps of restore factory defaults as follows: Press the button 

of  restore  factory  defaults,  power  on  the  device  again;  after 

3~4s, loosen the button to restore factory defaults. 

Checking LED Indicator

 

The  device  provides  LED  indicators  to  monitor  the  device 

working  status  with  a  comprehensive  and  simplified 

troubleshooting; the function of each LED is described in the 

table as below: 

LED 

Status 

Description 

PWR 

ON 

Power  supply  is  connected  and 

running normally 

OFF 

Power  supply  is  disconnected  or 

running abnormally. 

ALM 

ON 

Power supply, port link alarm 

OFF 

Power supply, port link without alarm 

RUN 

ON 

The  device  is  powering  on  or 

abnormal 

OFF 

The  device  isn't  powered  on  or  is 

abnormal 

Blinking 

Flash 1 time per second, the device 

is running normally. 

Link/Act   

(1-24) 

ON 

Ethernet port connection is active. 

Blinking 

Ethernet  port  is  in  network  active 

status 

OFF 

Ethernet port connection is inactive 

Logging in to WEB Interface

 

This  device  supports  WEB  management  and  configuration. 

Computer  can  access  the  device  via  Ethernet  interface.  The 

way  of  logging  in  to  device

’s  configuration  interface  via  IE 

browser is shown as below: 

Step 1 

Configure  the  IP  addresses  of  computer  and  the 

device  to  the  same  network  segment,  and  the 

network between them can be mutually accessed. 

Step 2 

Enter device

’s IP address in the address bar of the 

computer browser. 

 

Step 3 

Enter device

’s username and password in the login 

window as shown below. 

 

Step 4 

Click 

“OK” button to login to the WEB interface of 

the device. 

Note: 

 

The default IP address of the device is “192.168.1.254”. 

 

The  default  username  and  password  of  the  device  is 
“admin”. 

 

If the username or password is lost, user can restore it to 

factory  settings  via  device  DIP  switch  or  management 

software;  all  modified  configurations  will  be  cleared 

after  restoring  to  factory  settings,  so  please  backup 

configuration file in advance. 

 

Please  refer  to  user  manual  for  specific  configuration 

method  of  logging  in  to  WEB  interface  and  other 

configurations about network management function. 

Specification

 

Panel 

 

100M copper port

 

10/100Base-T(X)  self-adapting 

RJ45 

port, 

half/full 

duplex 

self-adaption, 

support 

MDI/MDI-X self-adaption

 

100M fiber port 

100Base-FX, 

optional 

SC/ST/FC interface 

Alarm interface

 

5  pins  5.08mm  pitch  terminal 

blocks, 

including 

alarm 

terminal blocks. Support 1 relay 

alarm 

output, 

current 

load 

capacity  is  5A@30VDC  or 

10A@125VAC.

 

Indicator 

Power  supply  indicator,  run 

indicator, 

interface 

indicator, 

alarm indicator 

Exchange Attributes

 

 

Backplane bandwidth

 

12.8G

 

Packet buffer size

 

3Mbit

 

MAC table size

 

8K

 

Power supply

 

 

Input power supply

 

100~240VAC/DC, support 

single or dual power supply 

scheme, and 8A output 

overcurrent protection 

Access terminal 

5  pins  5.08mm  pitch  terminal 

blocks,  including  3  pins  power 

supply terminal blocks

 

Consumption 

 

IES5024 

No-load: 7.4W@220VAC 

Full-load: 10.1W@220VAC

 

IES5024-2F 

No-load: 8.7W@220VAC 

Full-load: 11.4W@220VAC 

IES5024-4F 

No-load: 10W@220VAC 

Full-load: 12.7W@220VAC 

IES5024-8F 

No-load: 12.6W@220VAC 

Full-load: 15.3W@220VAC 

IES5024-12F 

No-load: 15.2W@220VAC 

Full-load: 17.9W@220VAC 

Pin Number

 

2

 

3

 

5

 

Pin Definition

 

TXD 

RXD 

GND 

Содержание IES5024 Series

Страница 1: ...ts are 24 port 100M layer 2 rack mounted managed industrial Ethernet switches Models include Model I IES5024 24 100M copper ports Model II IES5024 2F 22 100M copper ports 2 100M fiber ports Model III IES5024 4F 20 100M copper ports 4 100M fiber ports Model IV IES5024 8F 16 100M copper ports 8 100M fiber ports Model V IES5024 12F 12 100M copper ports 12 100M fiber ports Model VI IES5024 16F 8 100M ...

Страница 2: ...orts single power supply scheme power supply value range is 100 240VAC DC Dual power supply This series of products support dual power supply scheme and provide P1 and P2 independent power supply systems When one of the power supply system fails the device can operate uninterruptedly and normally which has improved the reliability of network operation Power supply value range is 100 240VAC DC Note...

Страница 3: ...n below Step 4 Click OK button to login to the WEB interface of the device Note The default IP address of the device is 192 168 1 254 The default username and password of the device is admin If the username or password is lost user can restore it to factory settings via device DIP switch or management software all modified configurations will be cleared after restoring to factory settings so pleas...

Страница 4: ...IES5024 16F No load 17 8W 220VAC Full load 20 5W 220VAC Environmental Limits Working temperature 40 75 Storage temperature 40 85 Working humidity 5 95 no condensation Protection grade IP30 metal shell ...

Отзывы: