The switch top panel provided 4 bit power supply input terminal
block, support DC input. DC power supply input supported
redundancy function, provided PWR1 and PWR2 power input,
can use for single, and can connect 2 separately power supply
system, use 1 pair terminal block connect the device at the same
time. If one of the power systems broke, the device can work
un-interruptible.
Built-in overcorrect protection,
Reverse
connection protection. Voltage input range is 12
~
48VDC
(
terminal block defined as: V1-
、
V1+
、
V2-
、
V2+
)
.
Important notice:
1.
Power ON operation: first of all, insert power cable’s terminal
block into device’s power port, then insert power supply plug into
power source
2.
Power OFF operation: First off all, unpin power plug, then
strike the terminal block, please take care of operation sequence.
【
Dimension
】
Unit (mm)
【
Communication connector
】
10/100/1000BaseT(X) Ethernet port
The pinout of RJ45 port display as below, connect by UTP or STP.
The connect distance is no more than 100m. 1000Mbps is used
120Ω of UTP 5e; 100Mbps is used 120Ω of UTP 5; 10Mbps is
used 120Ω of UTP 3, 4, 5.
RJ 45 port support automatic MDI/MDI-X operation. That can
connect the PC, Server, Converter and HUB. Pin 1, 2, 3, 4, 5, 6, 7,
8
Corresponding connections in MDI. 1→3, 2→6, 3→1, 4→7,
5
→8, 6→2, 7→4, 8→5, are used as cross wiring in the MDI-X
port of Converter and HUB. In MDI/MDI-X, 100/1000Base-TX
PIN defines is as follows:
PIN
MDI
MDI-X
1
BI_DA+/TX+
BI_DB+/RX+
2
BI_DA-/TX-
BI_DB-/RX-
3
BI_DB+/RX+
BI_DA+/TX+
4
BI_DC+/
—
BI_DD+/
—
5
BI_DC-/
—
BI_DD-/
—
6
BI_DB-/RX-
BI_DA-/TX-
7
BI_DD+/
—
BI_DC+/
—
8
BI_DD-/
—
BI_DC-/
—
Note
:
10Base-T/100Base-TX, “TX
±
”transmit data
±
, “RX
±
”receive data
±
,
“
—
”not use.
10/100Base-T(X) MDI (straight-through cable)
10/100Base-T(X) MDI-X (Cross over cable)
Gigabit MDI (straight-through cable)
Gigabit MDI-X (Cross over cable)
MDI/MDI-X auto connection makes switch easy to use for
customers without considering the type of network cable.