Unit: mm
Attention before mounting:
Don't place or install the device in area near water or
moist, keep the relative humidity of the device
surrounding between 5%~95% without condensation.
Before power on, first confirm the supported power
supply specification to avoid over-voltage damaging the
device.
The device surface temperature is high after running;
please don't directly contact to avoid scalding.
【
Mounting the Device
】
Step 1
Select the device mounting location to ensure
enough size.
Step 2
Use 4 screws to mount the mounting lugs to the
device as shown below.
Step 3
Place the device on the rack surface plate; adopt 4
screws to mount the right and left mounting lugs on
the rack.
Step 4
Check and confirm that the product is mounted
firmly on the rack, mounting ends
【
Dismounting the Device
】
Step 1
Device powers off.
Step 2
Unscrew the fixed mounting lug screw on the rack.
Step 3
Remove the device from rack, disassembling ends.
Note before power on:
Power ON operation: first connect power line to the
connection terminal of device power supply, then power
on.
The “—” of AC power supply switch means power-on
state; and “O” means power-off state.
Power OFF operation: first unpin the power plug, then
remove the power line, please note the operation order
above.
【
Power Supply Connection
】
2 AC power supplies
The Model IV of this series provides 2 AC power
supplies, two power supply systems inside the
device, one outlet outside. When one power supply
fails, it can switch to another one automatically and
immediately to ensure device
’s normal power supply. Power
supply input: 220VAC (100~240VAC)
1 DC power 1 AC power supply
The Model II of this series provides 1 DC power supply and 1
AC power supply:
Power
supply type
Power supply
Schematic
Power supply range
DC
48VDC
(
12~48VDC
)
AC
220VAC(100~240VAC)
2 DC power supplies
The Model I and Model III of this
series provide 1 6-pin 5.08mm pitch
input DC terminal. The power supply
occupies 4 pins and provides 2
independent power supply systems, PWR1 and PWR2. When
one power supply fails, it can switch to another one
automatically and immediately to ensure device
’s normal
power supply. Power supply input of Model I: 48VDC, power
supply range of Model III: 48VDC (12~48VDC).
【
Relay Connection
】
Relay terminal is a set of normally open contacts of device
’s
alarm relay. It is in open circuit status when it has no alarm,
close circuit when it has any alarm. For example: when
powered off, it
’s in close circuit and sending out alarm. This
switch supports 1 relay alarm information output, output power
supply alarm or network anomaly alarm. It can attach external
warning light, alarm buzzer or other switch states acquisition
device to warn operators in time when there has an alarm.
【
Flange Interface Connection
】
This device provides Bypass function. As shown below, A2
and B2 ends that on the left side represent internal terminal
blocks of flange interface, A1 and B1 ends that on the right
side of dotted line represent external terminal blocks of flange
interface.
Status
Description