3onedata IES3000 Series Скачать руководство пользователя страница 2

Unit: mm 

 

Attention before mounting:

 

 

Don't place or install the device in area near water or 

moist, keep the relative humidity of the device 

surrounding between 5%~95% without condensation. 

 

Before power on, first confirm the supported power 

supply specification to avoid over-voltage damaging the 

device. 

 

The device surface temperature is high after running; 

please don't directly contact to avoid scalding. 

Mounting the Device

 

Step 1 

Select  the  device  mounting  location  to  ensure 

enough size. 

Step 2 

Use  4  screws  to  mount  the  mounting  lugs  to  the 

device as shown below. 

 

Step 3 

Place the device on the rack surface plate; adopt 4 

screws to mount the right and left mounting lugs on 

the rack. 

 

Step 4 

Check  and  confirm  that  the  product  is  mounted 

firmly on the rack, mounting ends 

Dismounting the Device

 

Step 1 

Device powers off. 

Step 2 

Unscrew the fixed mounting lug screw on the rack. 

Step 3 

Remove the device from rack, disassembling ends. 

 

Note before power on:   

 

Power  ON  operation:  first  connect  power  line  to  the 

connection terminal of device power supply, then power 

on. 

 

The  “—”  of  AC  power  supply  switch  means  power-on 

state; and “O” means power-off state. 

 

Power  OFF  operation:  first  unpin  the  power  plug,  then 

remove  the  power  line,  please  note  the  operation  order 

above.

 

Power Supply Connection

 

 

2 AC power supplies 

The  Model  IV  of  this  series  provides  2  AC  power 

supplies,  two  power  supply  systems  inside  the 

device, one outlet outside. When one power supply 

fails,  it  can  switch  to  another  one  automatically  and 

immediately  to  ensure  device

’s  normal  power  supply.  Power 

supply input: 220VAC (100~240VAC) 

 

1 DC power  1 AC power supply 

The Model II of this series provides 1 DC power supply and 1 

AC power supply: 

Power 

supply type 

Power supply 

Schematic 

Power supply range 

DC 

 

48VDC

12~48VDC

 

AC 

 

220VAC(100~240VAC) 

 

2 DC power supplies 

The  Model  I  and  Model  III  of  this 

series provide 1 6-pin 5.08mm pitch 

input DC terminal. The power supply 

occupies  4  pins  and  provides  2 

independent power supply systems, PWR1 and PWR2. When 

one  power  supply  fails,  it  can  switch  to  another  one 

automatically  and  immediately  to  ensure  device

’s  normal 

power supply. Power supply input of Model I: 48VDC, power 

supply range of Model III: 48VDC (12~48VDC).

 

Relay Connection

 

Relay  terminal  is  a  set  of  normally  open contacts of device

’s 

alarm  relay.  It  is  in  open  circuit  status  when  it  has  no  alarm, 

close  circuit  when  it  has  any  alarm.  For  example:  when 

powered  off,  it

’s  in close circuit  and sending out  alarm.  This 

switch supports 1 relay alarm information output, output power 

supply alarm or network anomaly alarm. It can attach external 

warning  light,  alarm  buzzer  or  other switch states  acquisition 

device to warn operators in time when there has an alarm. 

Flange Interface Connection

 

This  device  provides  Bypass  function.  As  shown  below,  A2 

and  B2  ends  that  on  the  left  side  represent  internal  terminal 

blocks  of  flange  interface,  A1  and  B1  ends  that  on  the  right 

side of dotted line represent external terminal blocks of flange 

interface. 

Status 

Description 

Содержание IES3000 Series

Страница 1: ...power consumption Model II IES3000 8GT4GS 2BP P48P220 8 Gigabit copper ports 4 Gigabit SFP 2 Bypass 1 48VDC power supply 1 220VAC power supply Model III IES3000 8GT4GS 2BP 2P48 8 Gigabit copper ports 4 Gigabit SFP 2 Bypass 2 48VDC power supplies Model IV IES3000 8GT4GS 2BP 2P220 8 Gigabit copper ports 4 Gigabit SFP 2 Bypass 2 220VAC power supplies Panel Design Front view Model I Model II Model III...

Страница 2: ...let outside When one power supply fails it can switch to another one automatically and immediately to ensure device s normal power supply Power supply input 220VAC 100 240VAC 1 DC power supply 1 AC power supply The Model II of this series provides 1 DC power supply and 1 AC power supply Power supply type Power supply Schematic Power supply range DC 48VDC 12 48VDC AC 220VAC 100 240VAC 2 DC power su...

Страница 3: ...bugging port based on RS232 serial port which could connect to PC for device s CLI command management It adopts RJ45 port and its pin definitions are as follows Pin 2 3 5 Definition TXD RXD GND Checking LED Indicator The device provides LED indicators to monitor device s operation status and comprehensively simplify troubleshooting process The detailed status of each LED is described in the table ...

Страница 4: ...arrying capacity is 0 3A 125VAC or 1A 30VDC Indicator Running indicator port indicator power supply indicator alarm indicator Switch property Backplane bandwidth 24G Packet buffer size 4Mbit MAC address 8K Power supply Input power supply AC power supply product 220VAC 100 240VAC DC power supply product 48VDC 12 48VDC PoE product 48VDC Power consumption Model IV No load 5 9W 220VAC Full load 11 6W ...