Notice Before Mounting: 

 

Don't place or install the device in area near water or 
moist, keep the relative humidity of the device 
surrounding between 5%~95% without condensation. 

 

Before power on, first confirm the supported power 
supply specification to avoid over-voltage damaging the 
device. 

 

The device surface temperature is high after running; 
please don't directly contact to avoid scalding. 

DIN-Rail Mounting

 

Adopt 35mm standard DIN-Rail mounting which is suitable for 
most industrial scenes, mounting steps as follows: 

 

Step 1 

Check if the DIN-Rail mounting kit is installed firmly. 

Step 2 

Clip the upper part of the DIN-Rail mounting kit, i.e. 
the fixed side, into the DIN rail. 

Step 3 

Press the lower side of the device and insert the 
lower part of DIN-Rail mounting kit (the side with 
spring support) into DIN-Rail. 

Tips: 
The DIN-Rail spring support  is a metal sheet that can 
move up and down, and there will be a sound after it is 
clamped in. 

Step 4 

Check and confirm the product is firmly installed on 
DIN rail, then mounting ends. 

Disassembling DIN-Rail

 

 

Step 1 

Power off the device. 

Step 2 

Use a slot type screwdriver or other tools to move 
the DIN rail spring support downward; At the same 
time, move the lower side of the device outward 
and move out the lower part of the DIN rail 
mounting kit. 

Step 3 

Lift the device upward slightly, move out the upper 
part of DIN-Rail mounting kit. Disassembling ends. 

Notice before power on: 

 

Power ON operation: First insert the power supply 
terminal block into the device power supply interface, 
then plug the power supply plug contact and power on. 

 

Power OFF operation: First, remove the power plug, 
then remove the wiring section of terminal block. Please 
pay attention to the above operation sequence. 

Power Supply Connection

 

The device provides 6-pin 5.08mm pitch power 
supply terminal blocks and power supply occupies 
the top 4 pins. It supports two independent DC 
power supply systems, P1 and P2. The series of 
device supports redundant power supply, two 
power supply can work at the same time. The 

device will still run non-stop when one power supply fails. 
Power supply supports anti-reverse connection, which protect 
the device from damage but the device cannot be powered on. 
The definitions of power pin are shown in the left figure, and 
the power input range is 12~48VDC. 

Relay Connection

 

This device provides 6-pin 5.08mm pitch terminal 
blocks,  relay occupies the lower 2 pins. Relay 
terminals are a set of normally open contacts of 
the device alarm relay. They are open circuit in the 
state of normal non alarm, closed when any alarm 
information occurs. For example, they are closed 

when powered off, and send out alarm. The switch supports 1 
relay alarm information output that can output power supply 
alarm or network abnormality alarm. It can be connected to 
alarm light or alarm buzzer or other switching value collecting 
devices, which can timely inform operators when the alarm 
occurs.

 

DIP Switch Settings

 

The device provides 4-pin DIP switch for function 
setting, in which “ON” is the enabled end. The 
definitions of DIP switch are as follows: 

DIP  Definition  Operation 

Restore 
Factory 
Settings 

Set the DIP switch to ON, the device 
will root automatically and restore to 
factory settings, then turn off the DIP 
switch. 

2-4 

Reserved 

— 

Console Port Connection

 

The device provides 1 program debugging port 
based on RS-232 serial port which can conduct 
device CLI command management after 

connecting to PC. The interface adopts RJ45 port, the RJ45 
pin definition as follows: 

Pin No. 

Pin Definition 

TXD 

RXD 

GND 

Checking LED Indicator

 

The device provides LED indicators to monitor its operating 
status,  which has simplified the overall troubleshooting 
process. The function of each LED is described in the table 
below: 