background image

LINK 

ON 

The copper port has established 

an active network connection. 

Blinking 

The copper port is in a network 

activity state. 

OFF 

The copper port does not establish 

an active network connection. 

TX 

OFF 

The serial port is not sending data 

or sending abnormally 

Blinking 

The serial port is sending data   

RX 

OFF 

The serial port is not receiving data 

or receiving data abnormally 

Blinking 

The serial port is receiving data 

Logging in to WEB Interface

 

This  device  supports  WEB  management  and  configuration. 

Computer  can  access  the  device  via  Ethernet  interface.  The 

way  of  logging  in  to  device

’s  configuration  interface  via  IE 

browser is shown as below: 

 

Configure  the  IP  addresses  of  computer  and  the 

Step 1

device  to  the  same  network  segment,  and  the 

network between them can be mutually accessed. 

 

Enter device

’s IP address in the address bar of the 

Step 2

computer browser. 

 

 

Enter device

’s username and password in the login 

Step 3

window as shown below. 

 

 

Click 

“OK” button to login to the WEB interface of 

Step 4

the device. 

Note: 

 

The default IP address of the device is “192.168.1.254”. 

 

The  default  username  and  password  of  the  device  is 

“admin”. 

 

If the username or password is lost, user can restore it to 

factory  settings  via  device  DIP  switch  or  management 

software;  all  modified  configurations  will  be  cleared 

after  restoring  to  factory  settings,  so  please  backup 

configuration file in advance. 

 

Please  refer  to  user  manual  for  specific  configuration 

method  of  logging  in  to  WEB  interface  and  other 

configurations about network management function. 

Specification

 

Panel 

 

100M copper port

 

10/100Base-T(X) 

self-adaptive 

RJ45 port

 

Serial port

 

RS-232  RJ45  port  or  RS-485/422 

terminal 

 

Indicator 

Power  indicator,  network  Link/Act 

indicator,  serial  port  transmission 

and receiving data indicator 

Power supply 

 

Input power supply

 

9

48VDC

 

Access terminal 

2-pin 5.08mm terminal

 

Consumption 

 

Model I 

No-load: 0.53W@9VDC 

Full-load: 0.77W@9VDC 

Model II 

No-load: 0.86W@9VDC 

Full-load: 1.15W@9VDC 

Working 

environment 

 

Working temperature 

-40

75

 

Storage temperature 

-40

85

 

Working humidity 

5%

95% (non-condensing) 

Protection grade 

IP40 (metal shell) 

 