AM04-1  Sensitivity Adjustment 

The adjustment of AM04-1 is very  easy.  There are  only two  potentiometers on  PCB. These 
adjustments are  R31  (Sensitivity) and  R87 (Volume).  Both  of these adjustments will  increase the effect 
on  the system when  turned  to  the right (clockwise). 

SENSITIVITY 
The R31  adjustment varies the gain or sensitivity of the PCB.  Hold the label or tag  in a side carry at the 
desired  detection  distance

and then turn  R31  clockwise  until detection  is  made. 

MAXIMUM SENSITIVITY 
Use a multimeter to  connect to  TPD

(Red  Probe) and G N D  (Black Probe)

then turn  R31  and  make 

sure the voltage at this test  point is  never higher then  90mV

60-90mV is  ideal. 

A too  much higher DC Noise  (More  then  90mV)  will  cause  false  alarm. 

Sometimes,  the  detection at(under)  90mV may better then  over 90mV(such as  120mV). 

VOLUME 
The  R87 varies the volume of the sonalert or alarm  sounder for the desired  effect.  Turning this 
adjustment to  the  right (clockwise) will  increase the volume of the sounder. 

[] 