2.0 Environmental Conditions
This equipment has been tested and found to be safe to operate within
these environmental conditions.
This is not a warranty of equipment performance within these conditions.
• Indoor use only
• Ingress Protection: IPX0
• Altitude: Up to 2,000 m
• Mains supply voltage fluctuations up to ± 10% of the nominal voltage.
• Transient over-voltages up to the levels of overvoltage category II.
• Temporary over-voltages occurring on mains supply.
• Pollution degree: 2.
• Temperature: Maximum 110°
F / 43°
C Minimum 50
°
F/10
°
C
• Humidity: Maximum 80% relative humidity for temperatures up to 31° C
decreasing linearly to 50% relative humidity at 40° C.
3.0 Package Contents
Check that the following items are included with the 3M
™
WS Aware Workstation
Monitor shipping box
*
:
1 ea. WS Aware Workstation Monitor
2 ea. Remote terminals for wrist straps
1 ea. Ring terminal for grounding
1 ea. 6x32¼" Screw
1 ea. Power Supply Unit
2 ea. 10’ (3 m) mini-DIN cables for connection between 3M WS Aware Workstation Monitor and remote
terminals
1 ea. User’s Guide
*
Note: Packages containing custom configurations will contain items not included on this list.
4.0 General Product Specifications
Power Adapter
Universal Power Supply (included)
Input: 100 - 240VAC, 0.6A, ~ 50 - 60Hz
Output: 12VDC 1.5A, GlobTek Model GT-41080-1817.9-5.9 positive
For most locations, this universal power adapter has replaceable
clip-on blades.
Dimension (ap-
prox.)
3.2" W x2.25" H x1.30" D
(81mm W x 57 mm H x 33 mm D)
Weight (approx.)
120 g