background image

 

Installation Guide: 3M™ One-Piece GPS (TD4i) Offender Tracking System and Curfew Unit 

26 

6

 

Dismantling the One-Piece GPS Unit 

Dismantling the One-Piece unit involves: 

 

Performing an End of Service (when applicable). 

 

Removing and packing the One-Piece GPS Unit. 

 

Removing and packing the Curfew Unit. 

6.1

 

Before Dismantling 

Before leaving the monitoring center, check that you have the following dismantling tools: 

 

Strap installation tool – for measuring and cutting the strap 

 

0.2” (5mm) flathead screwdriver – for removing tamper plugs 

In addition, make sure to bring the original carrying case for the One-Piece GPS Unit and the Curfew Unit. 

6.2

 

Performing an End of Service 

In some cases, it is required to remove the One-Piece unit before full period of the offender’s monitoring 
program is completed. In this case, you must perform a manual End of Service procedure removing the 
One-Piece unit from the offender’s ankle. 

To perform End of Service: 

1.

 

Call the monitoring center and ask the monitoring personnel to perform End of Service. 

2.

 

The monitoring center personnel will call back to confirm a successful End of Service. You can 
now remove the One-Piece GPS Unit and Curfew Unit. 

6.3

 

Removing the One-Piece GPS Unit 

The strap installation tool includes a feature that enables you to cut the fiber optic strap in order to 
remove the One-Piece unit from the offender’s ankle.   

 

Figure 9: Position of Strap Cutting Slot on 3M™ Strap Installation Tool 

Strap Cutting Slot 

Содержание TD4i

Страница 1: ...3M One Piece GPS TD4i Offender Tracking System and Curfew Unit Installation Operation April 2017 Installation Guide 3M Electronic Monitoring ...

Страница 2: ...his publication may be reproduced transmitted transcribed stored in a retrieval system or translated into any language in any form by any means for any purpose other than the purchaser s personal use without the permission of 3M Electronic Monitoring 1995 2017 3M Electronic Monitoring All rights reserved Unless otherwise noted all names of companies products street addresses and persons contained ...

Страница 3: ...3M Electronic Monitoring 3 Versions and Changes Table Version Status Changes Author Date 1 0 Initial release version Steve Graniewitz 03 APR 2017 ...

Страница 4: ... Explanation of Signal Word Consequences WARNING Indicates a hazardous situation which if not avoided could result in serious injury or death CAUTION Indicates a hazardous situation which if not avoided could result in minor or moderate injury and or property damage NOTICE Indicates a situation which if not avoided could result in property damage Safety information for Rechargeable hand held weara...

Страница 5: ...s base units WARNING To reduce the risks associated with hazardous voltage Do not modify AC DC power adapter plug Do not force the power plug into an outlet where it does not fit Use only a 3M provided AC DC power adapter to recharge or power the device Do not unplug AC DC adapter by power cord Handle the adapter by the body only Do not attempt to charge the device using an outdoor outlet Only use...

Страница 6: ...ed prior to installation of device If during use the user experiences skin changes or symptoms in the area in contact with the electronic monitoring device the user should immediately contact their agency representative Cancer Patients that have been treated with Radiotherapy Avoid installing the electronic monitoring device in the presence of radiation induced skin changes such as ulcers open wou...

Страница 7: ... in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more ...

Страница 8: ... 4 1 3 Offender Information in the 3M Offender Management Software 17 4 2 Setting Up the 3M Curfew Unit 17 4 2 1 Curfew Unit LED Indication 18 4 3 Checking the One Piece GPS Unit s Battery Status 19 4 4 Attaching the Tamper Plugs 19 4 5 Preparing the Strap 20 4 6 Attaching the One Piece GPS Unit to the Offender s Ankle 22 4 7 Activating the One Piece GPS Unit 23 5 Status Alerts 24 5 1 Low Battery ...

Страница 9: ...able operators to efficiently track offenders at varying levels of intensity Each monitored offender is assigned a tracking unit which continuously tracks their location in real time The One Piece unit stores and processes the tracking data and communicates with the monitoring center or assigned officers to report the offender s location or alert in the event of a violation Alerts are configured a...

Страница 10: ...nts 2 1 LED Indicators The One Piece unit features three LED indicators that inform the offender of the unit s status If vibration notification is enabled the One Piece unit vibrates in order to prompt the offender to check the status of the LEDs The three LED indicators are labeled as follows PWR GPS Zone Activation Button LED Indicators Charging Port Pin Tray Bracket Fiber Optic Strap Zone PWR G...

Страница 11: ...d to be charged Flashing red once per second The One Piece unit is activated and the battery needs to be charged Solid green The One Piece unit is connected to the charger and the battery has been completely recharged You may remove the One Piece GPS unit from the charger Solid red The One Piece unit is connected to the charger and is not yet fully charged LED off The One Piece unit is not active ...

Страница 12: ... These indications are explained in the following table LED Indication LED Pattern Status Description PWR LED flashes red not in sequence with the other LEDs flashing green The activation sequence has begun All three LEDS flash green once per second The data transfer sequence has begun All three LEDS flash green GPS and Zone flash twice per second PWR LED is not in sequence The One Piece unit has ...

Страница 13: ...to send a command to the One Piece unit that causes the unit to vibrate and flash all three LED so that the offender will call the monitoring center LED Indication LED Pattern Status Description All three LEDs flash red once per second The One Piece has received a Vibrate Now command Press the Activation button to acknowledge ...

Страница 14: ...nd Cord Charger Attachment The Cord Charger attachment is connected to a wall mount power supply at one end and to the One Piece unit s charging port at the other The Cord Charger is attached to the One Piece unit using two magnets allowing quick and easy attachment and removal This method helps to prevent any damage to the device or the wearer in the event of unintended pulling 3 2 Cordless Charg...

Страница 15: ...nitoring 15 When attached to the One Piece unit the cordless charger charges the device while allowing the offender to go about their daily routine unhindered Figure 5 One Piece GPS Unit with Cordless Charger Attached ...

Страница 16: ...gement Software application 4 1 1 Installation Equipment The kit of installation equipment should include the following items One Piece GPS unit Power adapter Curfew Unit 1 strap 2 tamper plugs 2 pin trays 4 1 2 Installation Tools You will also need the following installation tools Strap installation tool for measuring and cutting the strap Flat head screwdriver for removing tamper plugs The One P...

Страница 17: ...nder Tracking Operational Guide 4 2 Setting Up the 3M Curfew Unit The Curfew Unit is an RF device that monitors the offender s presence in a fixed curfew area Figure 6 3M Curfew Unit The ideal location for the Curfew Unit is As close as possible to the center of the curfew site On a flat and secure surface 1m above the ground and at least 30cm away from the wall Not close to the ceiling Make sure ...

Страница 18: ... Unit on the middle floor To install the Curfew Unit 1 Place the Curfew unit in position according to the recommendations above 2 Connect the Curfew unit to power The Curfew Unit includes a rechargeable battery that enables the unit to continue functioning in the event of a power outage This battery is recharged automatically and recharging is not controlled by the user 4 2 1 Curfew Unit LED Indic...

Страница 19: ...ternal power is connected Off when external power is disconnected 4 3 Checking the One Piece GPS Unit s Battery Status To check the One Piece GPS Unit s Battery Status Press and hold the Activation button on the front of the One Piece unit for one second The PWR LED flashes green once If the PWR LED flashes red or not at all the One Piece unit needs to be charged 4 4 Attaching the Tamper Plugs On ...

Страница 20: ...ing a reinforced strap make sure that the copper wire is cut evenly and is not protruding from the strap 2 Spread the handles of the strap installation tool and insert the uneven end of the strap into the measuring slot Push the strap in until the edge of the strap is at the edge of the slot Squeeze the handles together to cut the end of the strap Keeping the handles together tilt the strap instal...

Страница 21: ...ray into the bracket of the strap installation tool 8 Place the strap installation tool with the strap around the offender s ankle 9 Insert the free end of the strap into the cutter slot and push it through to the other side 10 Tighten the strap to the desired length It should fit tightly around the offender s ankle allowing room for one finger between the offender s leg and the strap ...

Страница 22: ...e the strap is cut to size with a pin tray attached to both ends you are ready to attach the One Piece unit to the offender s ankle To attach the One Piece unit to the offender s ankle 1 Insert the strap with the attached pin tray into one of the pin tray brackets until it snaps into place 2 Place the One Piece unit on the offender s leg just above the ankle 3 Insert the other end of the strap int...

Страница 23: ...ins PWR GPS and Zone LEDs will begin to flash green once per second 3 After the data transfer is complete the GPS and Zone LEDs begin to flash green twice per second indicating that the One Piece unit is searching for a GPS signal Take the offender outside to acquire a GPS signal 4 After the GPS signal is received the Zone and GPS LEDs begin flashing three times per second indicating that the One ...

Страница 24: ...ce initially vibrates once The GPS LED flashes red once every second The device vibrates once every ten minutes until the violation has cleared by acquiring GPS 5 3 Strap Tamper A Strap Tamper alert occurs if the strap has been damaged or cut By default the One Piece unit does not indicate this condition If vibration notification is enabled the unit vibrates to indicate this status 5 4 Case Tamper...

Страница 25: ...resent during pre scheduled intervals If the offender is not within range of the Curfew Unit according to the defined schedule a violation condition is triggered Curfew Zone alerts are indicated as follows If vibration notification is enabled the device initially vibrates three times The Zone LED flashes red once every second until the zone violation is resolved If vibration notification is enable...

Страница 26: ... 6 2 Performing an End of Service In some cases it is required to remove the One Piece unit before full period of the offender s monitoring program is completed In this case you must perform a manual End of Service procedure removing the One Piece unit from the offender s ankle To perform End of Service 1 Call the monitoring center and ask the monitoring personnel to perform End of Service 2 The m...

Страница 27: ...mper plugs to break them 5 Use the screwdriver to remove the tamper plugs from the brackets 6 At one end of the strap use the screwdriver to depress the latch on the pin tray 7 While keeping the latch depressed pull the strap out of the bracket 8 Repeat steps 6 and 7 for the other end of the strap that is still attached 9 Collect the tamper plugs pin trays and pieces of strap that you have disasse...

Страница 28: ...i Offender Tracking System and Curfew Unit 28 6 4 Removing the Curfew Unit To remove the Curfew Unit 1 Disconnect the Curfew Unit from the external power source The Curfew Unit turns off 2 Pack the Curfew Unit into its original carrying case ...

Отзывы: