manualshive.com logo in svg
background image

3M

 Cross-Connect Cabinets 4220 and 

4230 with 3M

 Self-Strip Blocks 4320 

and 3M

 Quick Connect System (QCS) 

2810 Blocks

Instructions

March 2011

78-8122-3169-0-F

3

Содержание SS 4320

Страница 1: ...3M Cross Connect Cabinets 4220 and 4230 with 3M Self Strip Blocks 4320 and 3M Quick Connect System QCS 2810 Blocks Instructions March 2011 78 8122 3169 0 F 3...

Страница 2: ...nting Pads for Cabinets 10 6 0 3M Cross Connect Cabinet Installation 13 7 0 Cable Port Sealing 14 8 0 Shield Bonding 18 9 0 Cable Termination to the 3M Self Strip Blocks 4320 18 10 0 Identification of...

Страница 3: ...t Maximum Pair Capacity Cabinet Pair Count Provided Connector on the end of stub of the Block Cabinet Color Almond Cabinet with 3M Quick Connect System QCS 2810 Blocks 4220V G SSHCTO 3600 1800 GBM A C...

Страница 4: ...9 3 4 X X 4220EE 1800 2 SS9 36 1 2 x 18 x 49 3 4 X X 4220ET 1350 1 SS1350 36 1 2 x 18 x 64 3 4 X X 4220EET 2700 2 SS1350 36 1 2 x 18 x 64 3 4 X X Cabinets with 3M Quick Connect System QCS Blocks Block...

Страница 5: ...1 2 x 26 x 64 3 4 X X 4230K 5400 6 SS9K 57 1 2 x 26 x 64 3 4 X X 4230KT 5400 6 SS9K 57 1 2 x 26 x 68 3 4 X X 4230T 3600 4 SS9K 44 x 26 x 68 3 4 X X Cabinets with 3M Quick Connect System QCS 2810 Bloc...

Страница 6: ...26 x 49 3 4 X X Cabinets with 3M Quick Connect System QCS 2810 Blocks Cabinet Product Max Pair Count QCS 2810 Max of Frames QCS 2810 Frame Number Dimensions Width Depth Height Single Sided Double Sid...

Страница 7: ...s Connect Cabinets D DD F G Series 3M Frame SS9 for use in 3M Cross Connect Cabinets E EE Series 3M Frame SS9K for use in 3M Cross Connect Cabinets KF K KT T and LF L Series 3M Frame SS6N for use in 3...

Страница 8: ...D F G cabinets b 3M Chamber Cover 4246 K for 3M Quick Connect System QCS Covers empty frame positions in KF K LF L cabinets 3 2 3M Mounting Rings To anchor cabinets onto the concrete slab a 4256 D DD...

Страница 9: ...10 Blocks 3 7 3M Self Strip Replacement Caps 4320 100 tan 100 orange 3 8 Caps for 3M Quick Connect System QCS 2810 Blocks 3 9 3M Priority Circuit Caps 4324 For protecting priority circuits 4324 R 4324...

Страница 10: ...24 AWG orange white jumper wire 4069 250 24AWG orange white jumper wire 4368 800 22 AWG red white jumper wire 4369 250 22 AWG red white jumper wire 4368 800 22 AWG red white jumper wire 4369 250 22 A...

Страница 11: ...odules 4 2 3M 710 Uni Presser 25 Pair Cutter Presser For splicing 3M 710 Connectors 4 3 3M Self Strip Pair Pocket Test Probe 4327P 4 4 3M Self Strip Pair Probe and Dish 4327 A 3M Self Strip Pair Probe...

Страница 12: ...es the anchor bolts Figure Model A B Used With Cabinets 1 4256 D DD 26 19 D DD Series 1 4256 E EE 41 19 E EE ET EET Series 2 4256 F G 62 19 F G KF K MF M LF L KT Series Cable duct location markers Ope...

Страница 13: ...he bottom of the mounting ring with bolts anchors and bolts provided with ring Note Anchors can be located for either internal or external attachment to the cabinet Note Side of mounting ring can be c...

Страница 14: ...t internal or external attachment to cabinet Model Overall Pad W x D Cable Ducts Sweeps Entry Location Concrete Anchor Location Number A B C D E F G H J K 4220 D DD Internal 38 60 9 19 26 7 11 16 25 1...

Страница 15: ...rames to minimize weight c Remove top and front access panels front cable port plate and lower frame support Note If a lift boom truck is used reposition the two side lifting straps for attachment of...

Страница 16: ...Position 6 6 Reverse the doors and removable back panel to install a 3M Cross Connect Cabinet 4220 D E F KF KT or 4230 MF or LF against a wall or obstruction Note Mounting pad requirements are the sa...

Страница 17: ...sealant tape a Remove cable sheath b Clean and scuff cable in location of cable ports c Install shield connectors and attach bond straps making sure that the straps will reach the bond plate Sheath re...

Страница 18: ...larger than the inside diameter of the ports f Slide the tape bundle down into the port openings Leave a 1 2 of space between the tape and the top of the ports for foam expansion Tighten all bolts g M...

Страница 19: ...he front plate from the flexible port entry kit Install the port body onto the threaded studs f Place cables into port and install the front plate Wrap each cable with at least one layer of foam tape...

Страница 20: ...c Fill sleeve with Re enterable Encapsulant 8882 Pedestal Base Sealant 4411 or Encapsulating and Blocking Compound 4407 Note Carefully follow safety health and environmental information on the produc...

Страница 21: ...connector s and the cabinet bond plate 8 2 Identify cable bond straps on bond log label in the cabinet 9 0 Cable Termination to the 3M Self Strip Blocks 4320 9 1 Break feeder and distribution field c...

Страница 22: ...ies 3M Cross Connect Cabinets E EE Series ET EET Series Cabinets in 3M Cross Connect Cabinets F G Series KF K Series Cabinets in 1 300 D I S T R I B U T I O N 301 600 D I S T R I B U T I O N 601 900 D...

Страница 23: ...r company procedure d Cable tie groups creating adequate slack to lower frames Cable Frame Support 9 5 Cable slack storage in the frame optional a Dress field cable to complete an up and down loop of...

Страница 24: ...the same method as the frames h Splice the field conductors and block tails following your company practice i Complete the splicing and install the frame Attach the safety cable to the frame j Bundle...

Страница 25: ...it port 11 3 With a screwdriver blade fully inserted into post slot rotate post 90 clockwise until the wire end cuts off The post slot should be horizontal Note The wire cut off is the indication that...

Страница 26: ...aps test ports b Depress the clamps to allow clearance over cap heads Push probe forward until clamps snap behind cap head c 3M Self Strip Pocket Test Probe 4327P This probe is installed with the same...

Страница 27: ...ur company procedure d Cable tie groups creating adequate slack to lower frames Cable Frame Support 13 4 Cable slack storage in the frame optional a Dress field cable to complete an up and down loop o...

Страница 28: ...ompany practice i Complete the splicing and install the frame Attach the safety cable to the frame j Bundle the splices in the frame the same as the other frames k Secure all frames in the upright pos...

Страница 29: ...y repeating the procedure described in steps 15 1 and 15 2 15 5 Terminate additional jumper wires by repeating the above procedure 15 6 To remove jumper wires open the cap and pull wires straight out...

Страница 30: ...17 3 Standard 3M Cross Connect Frames SS6 or SS9K or narrow 3M Cross Connect Frames SS300N or SS450N can be mounted along side the equipment rack s for combined electronics fiber and cross connect ap...

Страница 31: ...78 8122 3169 0 F 31...

Страница 32: ...Warranty Limited Remedy Limited Liability This product will be free from defects in material and manufacture for a period of one 1 year from the time of purchase 3M MAKES NO OTHER WARRANTIES INCLUDIN...

Отзывы: