3M
™
Adflo
™
Powered Air Respirator
To optimise the effective lifetime of your welding equipment and avoid the additional cost of replacement, regular
maintenance is important. Replace all damaged parts immediately to ensure correct levels of protection.
• Battery. Ensure that it’s adequately charged and fitted
correctly.
• Motor Body. Inspect the unit for damage and ensure it’s
firmly fixed to the belt. Ensure filters are correctly fitted.
• Breathing tube. Inspect the tube and connections
to ensure they are free from splits and holes.
Replace if damaged, deformed or leaking any air.
To extend the life of the breathing tube, use a tube cover
or the heavy-duty rubber breathing tube.
• Air flow check. Fit the breathing tube to the unit and
attach the airflow meter in the other end of the tube and
switch on the Adflo PAPR. If the ball does not rise above
the line, continue fault finding.
• Alarm check. Cover the air outlet of the airflow
meter with your hand until an audible warning is heard
and the red indicator illuminates. Remove your hand.
The alarm should now stop.
834017
834018
835000
835005
836000
836010
837010
837110
837120
837242
837542
837620
837621
837630
837631
837730
837731
838031
ADAPTOR ADFLO BREATHING TUBE 9100 FX AIR
ADAPTOR QRS BREATHING TUBE TO 9000
PAPR MOTOR WITH HOUSING ADFLO
CHARGER BATTERY NIMH ADFLO
CHARGER BATTERY LI-ION ADFLO
BATTERY MULTI-STATION ADFLO
TUBE BREATHING SELF ADJUSTING QRS ADFLO
TUBE BREATHING HEAVY DUTY RUBBER QRS ADFLO
TUBE BREATHING COVER FLAME RESISTANT ADFLO
BELT ADFLO
BELT EXTENSION ADFLO
SPARK ARRESTOR ADFLO
PRE-FILTER ADFLO PK=5
FILTER PARTICLE PSL ADFLO
FILTER ODOUR ADFLO
FILTER ODOUR REPLACEMENT PAD ADFLO
FILTER NUIS LEVEL ORGANIC VAPOUR/ACID GAS
ADFLO FILTER GAS A1 ADFLO
BATTERY STANDARD NIMH ADFLO
BATTERY HEAVY DUTY NIMH ADFLO
BATTERY STANDARD LI-ION ADFLO
BATTERY HEAVY DUTY LI-ION ADFLO
RESPIRATOR STANDARD LI-ION ADFLO
RESPIRATOR HEAVY DUTY LI-ION ADFLO
FILTER COVER LI-ION ADFLO
Part No
Before use
After use
• Clean the equipment. Wipe the motor body with a moist tissue or
cloth. If you suspect that the inside of the breathing tube is dirty,
it must be changed.
DO NOT rinse, immerse in water or clean with solvents.
DO NOT attempt to remove contamination of filters as this will damage
the filters and void the warranty.
• Replace damaged parts. Replace all damaged parts to guarantee the
proper functioning of the respirator. Worn out components should be
disposed of according to local regulations.
• Spark arrestor. Replace if deformed and no longer fitting well.
• Prefilter. Replace regularly to extend the life of the particle
filter. This will save money and also extend the battery run-time.
• Particle filter. Check the filter indicator position and replace if
the red LED is lit. Otherwise, replace whenever the battery operating
time becomes too short, or when “fully loaded” filter triggers low
airflow alarm.
• Gas filter. Replace the gas filter according to your work place
requirements. Do not wait until you can sense odours or smells.
• Odour filter. Replace any time you smell unpleasant odours.
Odour filter is not required if gas filter is used.
• Storage. Put the battery/turbo unit on charge after use. When stored,
recharge every six months. Store the unit in a dry, clean area away
from direct sunlight, high temperatures and solvents. For example use
the Adflo storage bag.
To request a quote or place an order for spare parts, please contact TWS on +61 (0)
7
46
5
9 0044 or visit www.tweld.com.au. Please note that higher than normal levels
of pollutants, heat and sparks will require more frequent replacement of components. If you require additional guidance, please check the care and maintenance videos on our
YouTube Channel (
www.youtube.com/user/3MSpeedglas
) or contact your local TWS representative.
Further information and advice
Care & Maintenance
533505
533506
832000
833101
833111
833709
834016
Description
Part No Description
Part No Description
Part No Description
Authorised 3M Wholesaler
Unit 13, 39 Herbert Street • St Leonards NSW 2065 • Australia
T: (02) 9439 0111 • F: (02) 9439 0100
W: www.speedglas.com.au
83 80 30 83 60 00
83 60 10
83 60 80
83 70 10
83 70 80
83 50 00
83 50 10
83 31 01
83 25 30
83 76 20 83 80 20
83 71 20
83 71 10
83 72 42
83 20 00
83 76 21
83 32 09
83 40 16
83 40 17
83 75 42
83 50 05
83 40 18
53 35 06
83 76 31
83 76 20
83 76 21
83 80 31
83 76 30
83 31 11
83 77 30
83 31 01
83 80 30 83 60 00
83 60 10
83 60 80
83 70 10
83 70 80
83 50 00
83 50 10
83 31 01
83 25 30
83 76 20 83 80 20
83 71 20
83 71 10
83 72 42
83 20 00
83 76 21
83 32 09
83 40 16
83 40 17
83 75 42
83 50 05
83 40 18
53 35 06
53 35 05
* Speedglas 9000 headtop breathing tubes.