3M RESPIRATOR N95 PARTICULATE 8211 Скачать руководство пользователя страница 3

3

Time Use Limitations

If respirator becomes damaged, soiled, or breathing becomes difficult, leave the contaminated area
immediately and replace the respirator.

Fitting Instructions

Must be followed each time respirator is worn.

Fig.1

Fig. 2

Fig. 3

Fig. 4

1.

Cup the respirator in your hand, with the nosepiece at your fingertips, allowing the headbands to hang
freely below your hand.

2.

Position the respirator under your chin with the nosepiece up.  Pull the top strap over your head
resting it high at the top back of your head.  Pull the bottom strap over your head and position it
around the neck below the ears.

3.

Place your fingertips from both hands at the top of the metal nosepiece.  Using two hands, mold the
nose area to the shape of your nose by pushing inward while moving your fingertips down both sides
of the nosepiece.

  Pinching the nosepiece using one hand may result in improper fit and less effective respirator
performance.  Use two hands.

4.

Perform a User Seal Check prior to each wearing.  To check the respirator-to-face seal, place both
hands completely over the respirator and inhale sharply.  Be careful not to disturb the position of the
respirator.  A negative pressure should be felt inside the respirator. If air leaks around nose, readjust

Содержание RESPIRATOR N95 PARTICULATE 8211

Страница 1: ... 8211 07185 Respirator N95 Particulate User Instructions Keep these instructions for reference 07185 is a catalog number only NIOSH approved as 3M 8511 N95 Particulate Respirator See insert for approval label ...

Страница 2: ... written respiratory protection program must be implemented meeting all the requirements of OSHA 29 CFR 1910 134 such as training and fit testing and applicable OSHA substance specific standards In Canada CSA standard Z94 4 93 requirements must be met 3 The particles which can be dangerous to your health include those so small that you cannot see them 4 Leave the contaminated area immediately and ...

Страница 3: ...ull the bottom strap over your head and position it around the neck below the ears 3 Place your fingertips from both hands at the top of the metal nosepiece Using two hands mold the nose area to the shape of your nose by pushing inward while moving your fingertips down both sides of the nosepiece Pinching the nosepiece using one hand may result in improper fit and less effective respirator perform...

Страница 4: ...rvisor Removal Instructions See step 2 of Fitting Instructions and cup respirator in hand to maintain position on face Pull bottom strap over head Still holding respirator in position pull top strap over head and remove respirator NIOSH Approved N95 At least 95 filtration efficiency against solid and liquid aerosols that do not contain oil This respirator contains no components made from natural r...

Страница 5: ...sentative or call 3M OH ESD Technical Service toll free in U S A 1 800 243 4630 In Canada call Technical Service at 1 800 267 4414 Exported by Exporté par Exportado por 3M Occupational Health and Environmental Safety Division 3M Center Building 235 2W 70 P O Box 33010 St Paul MN 55133 3010 Made in U S A 3M 2001 38 9017 1404 8 ...

Отзывы: