2.4 BASE/PORTABLE UNIT
 

  2.4.1 SWITCHING A BASE/PORTABLE UNIT ON

 

   

 

Switch a base unit on by pressing the [

M

] button.

 

   

  In a headset, connected in the headset connector on the unit, a voice confirmation 

“BASE, POWER ON”

 

 

   

  is given and the 

LED

 (light emitting diode) is flashing, showing that the base unit is setting up the system.

 

Notice: 

Initially, a base/portable unit is starting up as a base. (See also 

 

ALTERNATIVE OPERATION MODES OF BASE/PORTABLE UNITS below.)

 

   

  After approximately 20 seconds, the system is ready and a voice message 

“GROUP 1”

 is given. The 

LED

 on the unit is flashing

  

   

  slower, showing that the base unit is ready for use and portable units can be logged on. (The LED can be switched off with use 

 

   

  of special DECT-Com II software.) 

 

  2.4.2 SWITCHING A BASE/PORTABLE UNIT OFF

 

   

 

Switch a base unit off by pressing and holding the [

M

] button for approximately 2 seconds. 

 

   

  A voice confirmation 

“POWER OFF”

 is given, the 

LED

 is unlit, and the unit is turned off.

 

  2.4.3 ALTERNATIVE OPERATION MODES OF BASE/PORTABLE UNITS

 

   

By different start-up sequences the 

base/portable

 main units can be set up to work either as a base or as a portable unit. 

 

   

2.4.3.1 STARTING A BASE/PORTABLE UNIT AS A PORTABLE UNIT

 

   

 

 

Switch the unit on by pressing and holding the [

M

] and [

] buttons simultaneously for approximately 2 seconds. 

 

   

    In a headset, connected in the headset connector on the unit, a voice confirmation 

“POWER ON”

 is given, 

 

   

    confirming that the unit is started as a portable unit.

 

   

    After approximately 15 seconds, the unit is ready and a voice message 

“BASE #, GROUP 1”

 is given. The 

LED

 

 

   

    on the unit is lit, showing that the unit is ready for use as a portable unit, and is logged on to base No. #.

 

   

    (The LED can be switched off with use of special DECT-Com II software.) 

 

Notice: 

All units are always started in listen only mode in group 1.

 

Last used alternative (base or portable) is remembered between sessions.

 

   

2.4.3.2 STARTING THE UNIT AS A BASE UNIT

 

   

 

 

Switch the unit on by pressing and holding the [

M

] and [

+

] buttons simultaneously for approximately 2 seconds. 

 

   

    In a headset, connected in the headset connector on the unit, a voice confirmation 

“BASE, POWER ON”

 is given, 

 

   

    confirming that the unit is started as a base unit.

 

   

   

After approximately 20 seconds, the system is ready and a voice message 

“GROUP 1”

 is given. The 

LED

 on the 

 

   

    unit is flashing slower, showing that the base unit is ready for use and portable units can be logged on.

 

   

    (The LED can be switched off with use of special DECT-Com II software.) 

 

   

    A user with a headset connected in the headset connector on a base unit can also be participating in a 

 

   

    DECT-Com II conference, similar to a portable unit. (See also parts 3, 4 and 6.)

 

Notice: 

All units are always started in listen only mode in group 1.

 

Last used alternative (base or portable) is remembered between sessions.

 

  2.4.4 MAKING A BASE UNIT READY FOR PORTABLES TO BE REGISTERED 

 

   

  Each portable unit should be registered to a base unit to be part of a DECT-Com II conference.

 

   

 

With the base unit in 

LISTEN-ONLY

 and 

VOLUME

 mode, double press on the [

M

] button to enter 

REGISTRATION

 mode. 

 

   

  A base unit in 

REGISTRATION

 mode is indicated by slow flashing 

LED

.  

 

   

 

When all portable units are registered to the base unit, exit 

REGISTRATION

 mode by briefly pressing [

MODE

] button.

Содержание Peltor DECT-Com II

Страница 1: ...3MTM PeltorTM DECT Com IITM Full Duplex Wireless Intercom Instruction Manual...

Страница 2: ...nference 1 Press once to listen in conference 1 For latest revised full user s instructions please see www 3m com peltorcomms on the Internet Look in section Rest of the world and find PDF LIBRARY whe...

Страница 3: ...ONTROLS 4 1 Mode 4 2 PTT Push To Talk 4 3 All Call Emergency Call etc 4 4 Locked buttons 5 OUT OF RANGE 6 POWER SUPPLY 6 1 Internal Batteries 6 2 External Batteries 6 3 Fixed Mounted Power Supply 6 4...

Страница 4: ...lude or restrict 3M s liability for death or personal injury arising from its negligence 2 MAIN UNITS 2 1 PREPAIRING THE MAIN UNIT Open the main unit box Mount one of the three antenna rings on the an...

Страница 5: ...and a voice message BASE GROUP 1 is given The LED on the unit is lit showing that the unit is ready for use as a portable unit and is logged on to base No The LED can be switched off with use of spec...

Страница 6: ...E UNIT ON A BASE Each portable unit is registered to at least one base unit to be part of a DECT Com II conference The unit is searching for bases A voice message SEARCHING is given With the portable...

Страница 7: ...available bases and an auto setting A voice confirmation is given for each available choice AUTO ONE TWO Stop at your preferred base number or auto see below Log on to the base by pressing the M butto...

Страница 8: ...n be set in 5 steps Use the or button to set the sound level from the DECT Com unit A voice message confirms the new setting each time you press a button 4 1 1 1 VOLUME BOOST higher sound pressure The...

Страница 9: ...ronisation should be done by starting the systems in range of each others If this function should always be accessible the bases have to constantly be in range for instance as fixed mounted bases If t...

Страница 10: ...ergy in the battery is very close to empty and the unit will automatically switch off 6 1 3 CHARGING AN INTERNAL BATTERY PACK A rechargeable NiMH battery DC2033 has to be charged in a main unit with a...

Страница 11: ...of the main unit enabling automatic restart after shorter power outages 6 4 MAINS ADAPTER There is also a separately sold mains adapter DC2061 with exchangeable European UK and US type mains connector...

Страница 12: ...s excl batteries DC2033 Rechargeable NiMH accumulator 2100 mAh DC2035 Screw for battery lid DC2031 DC2036 Screw for battery carrier DC2032 DC2041 Antenna general 1 9 GHz for main unit DC2046 Antenna o...

Страница 13: ...ery approx 6 h base unit Peltor DC2033 approx 40 h portable unit With 6xAA additional 2100 approx 18 h base unit mAh NiMH batteries in DC2032 approx 165 h portable unit Usage temperature 26 C to 55 C...

Страница 14: ...operation of the device The Term IC before the certification registration number only signifies that the Industry Canada technical specifications were met 12 WARRANTY Two year guarantee of conformity...

Страница 15: ...A BASE UNIT ON 2 2 4 LOG ON A PORTABLE UNIT TO A BASE 3 1 LOG IN AS A LISTEN ONLY CONFERENCE MEMBER LOGIN 2 2 6 SELECT A BASE FROM A PORTABLE UNIT MICROPHONE 4 1 MODE OUT OF RANGE 2 2 4 LOG ON A PORT...

Страница 16: ...ng information 1 Name 2 Address 3 Phone 4 Fax if one is available 5 Enclose a letter stating the problem 6 If unit is under warranty a copy of the receipt must be included 7 If unit is not under warra...

Страница 17: ...The Sound Solution 18...

Отзывы: