![3M MictoTouch EX712 Скачать руководство пользователя страница 33](http://html.mh-extra.com/html/3m/mictotouch-ex712/mictotouch-ex712_reference-manual_442637033.webp)
3M™ MicroTouch™ Controller EX712 Reference Guide
33
3M Touch Systems, Inc. Proprietary Information
Ambient Operating and Storage Environmental Conditions
All Humidity is Non-Condensing
Operating Temperature Range
- 40
°
C to +70
°
C
Operating Humidity Range
<36° C 0-95% RH
≥
36
°
C
Storage Temperature Range
- 50
°
C to +85
°
C
Storage Humidity Range
< 36°C 0-80% RH
≥
36
°
C
Performance and Reliability
Minimum Touch Duration
As low as
3 msec.
Touch Resolution – (Maximum addressable coordinates generated by the controller) 16K
x 16K
ESD Susceptibility -
±
8 kV Contact Discharge
*
– Class 2 per section 9 of IEC 61000-4-2
Compliant
1 false touch allowed
±
27 kV Air Discharge
*
– Class 1 per section 9 of IEC 61000-4-2
Compliant
Normal Operation – No false touches
* ESD discharges to a 3M™ MicroTouch™ sensor connected to the controller
MTBF (by MIL Std. 217F Calculation)> 700,000 Hours
Touch System Parameters
Accuracy vs. Dynamic Temperature Change Maintains 1% Accuracy
(tested at 0 deg. C to 60 deg. C with a 0.5 deg. C/minute temperature ramp)
Sensor Compatibility
3M™ MicroTouch™ Capacitive Sensors
Communications Protocol
Serial RS 232