3M High Flow Series Скачать руководство пользователя страница 6

Equipment Start-up Procedure

1.   Turn on incoming water to system.
2.   Pressurize system by rotating the inlet ball valve handle 1/4 turn counter-clockwise to the “ON” position.
3.   Check for leaks.
4.   Use any downstream vent to remove trapped air. 
5.   Flush system in accordance with the Performance Data Sheet for the water filter cartridge.  System is now 

ready to use.

Cartridge Change-out Procedure

CAUTION

To reduce the risk associated with property damage due to water leakage:

  • Read and follow 

Use Instructions before installation and use of this system.

  • Installation and Use 

MUST

 comply with all state and local plumbing codes.

  • The disposable filter cartridge 

MUST

 be replaced every 12 months or at the rated capacity or if a noticeable 

reduction in flow rate occurs.

The water filter cartridge will need to be changed every 6-12 months or when low pressure is indicated on the 
manifold’s pressure gauge, whichever occurs first. Depending on local water quality, you may need to change the 
cartridges prior to the recommended change-out.

1.  Shut off the inlet water by rotating the inlet ball valve 1/4 turn clockwise to the “OFF” position.
2  Depressurize system.
3.  Push tab to release cartridge locking mechanism while simultaneously rotating cartridge slightly to the left.
4.  Using both hands and holding cartridge from the bottom, rotate the cartridge a quarter turn to the left and 

gently pull down. IMPORTANT NOTE: A small amount of water will drain from manifold as cartridge is re-
moved.

5.  Remove sanitary cap from new cartridge. Install cartridge with a quarter turn to the right until cartridge comes 

to a complete stop. 

6.  Remove the small scale inhibitor cartridge by rotating to the left (counterclockwise) until the threads are dis

-

engaged.  Replace with a new cartridge by rotating to the right (clockwise) until the threads are fully engaged 

and snug, regardless of final label orientation. 

7.   Slowly turn the inlet ball valve on the manifold 1/4 counter-clockwise to the “ON” position and check for 

leaks.

8.  Flush system in accordance with the Performance Data Sheet. System is now ready for use.

6

No water flow through system

Inlet valve closed

Filter clogged

Check shut-off valve position

Replace cartridge

Not enough water to the 

downstream application(s)

Low incoming water pressure

Filter clogged

Check source

Replace cartridge

Short filter life

Temporarily dirty water

Change cartridge or install an 
additional upstream pre-filter.

Troubleshooting

Содержание High Flow Series

Страница 1: ...cale Feeder Manifold Water Filtration System Instruction Manual For SF1XX High Flow Series Water Filtration Systems 3MTM Water Filtration Products Installer Please leave this manual with owner operato...

Страница 2: ...if not avoided could result in death or seri ous injury and or property damage CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or moder ate injury and or p...

Страница 3: ...C Do not install on hot water supply lines The maximum operating water temperature of this filter system is 100 F 37 8 C Do not install if water pressure exceeds 125 psi 862 kPa If your water pressure...

Страница 4: ...i circular in shape with three internal tabs bottom center and top Tab interlaces with windows in the manifold head near each connection port Clip is flexible and easily assembled following these inst...

Страница 5: ...s 3 Select fasteners not included and tools appropriate for the installation location wall support structure mount ed to wall studs concrete etc CAUTION To reduce the risk associated with property dam...

Страница 6: ...sition 2 Depressurize system 3 Push tab to release cartridge locking mechanism while simultaneously rotating cartridge slightly to the left 4 Using both hands and holding cartridge from the bottom rot...

Страница 7: ...1 Scale inhibitor addition 4 85005 49 Pressure gauge 1 Monitor outlet water pressure 5 85 8528 Clip 1 Retain inlet outlet fittings 6 63597320 O ring 1 Seal inlet outlet fittings 7 6225005 Inlet fittin...

Страница 8: ...agraph is Customer s sole remedy and 3M Purification Inc s exclusive obligation This warranty gives you specific legal rights and you may have other rights which may vary from state to state or countr...

Отзывы: