GVP-123 – Maintenance / GVP-1 - Disassembly
© 3M June 2006. All rights reserved.
temperature between 41º F to 77º F (5º C to 25º C). The time
required for a full charge will increase and the potential recharge
cycles will be reduced if charging takes place above 77º F
(25º C).
d. To charge the battery:
i. Plug the GVP-112 Battery Charger into a 115-volt AC
outlet and push the connector into the battery.
ii. A red light on the battery charger indicates an electrical
connection to the battery has been made. The light on
the charger will remain on as long as electrical power is
available and the charger is functioning.
e. To properly dispose of the battery, follow local solid waste
disposal regulations or the RBRC Battery disposal regulations
or call the RBRC Battery Recycling Information Help Line at
1-800-8-BATTERY (1-800-822-8837).
f. Additional
battery Information:
i. The initial charge on the battery should be for a minimum
of 20 hours prior to use. Recharge the battery for 14-16
hours when the red battery recharge indicator light
comes on during use or after every 6 to 8 hours of use.
This battery is not harmed if it is left on a continuous
charge past the normal 14-16 hour recharge time.
However, a continuous charging for extended periods of
time will reduce the life of the battery. Therefore, we
recommend that a continuous charge be limited to no
more than 1 week. The battery will lose approximately
20% of its capacity per month without use.
6) The GVP-115 is the set of Plugs used when cleaning the motor
blower
. The plugs should be replaced when they are damaged, worn
or missing. To remove the plugs:
a. Unscrew the GVP-115 Blower Plug and Filter Plug from the
motor blower unit.