3M GVP-1 Скачать руководство пользователя страница 3

GVP-123 – Maintenance / GVP-1 - Disassembly 

 

© 3M June 2006.  All rights reserved. 

temperature between 41º F to 77º F (5º C to 25º C). The time 
required for a full charge will increase and the potential recharge 
cycles will be reduced if charging takes place above 77º F  
(25º C). 

 
d.  To charge the battery: 
 

i.   Plug the GVP-112 Battery Charger into a 115-volt AC 

outlet and push the connector into the battery. 
 

ii.  A red light on the battery charger indicates an electrical 

connection to the battery has been made. The light on 
the charger will remain on as long as electrical power is 
available and the charger is functioning. 

 

e.  To properly dispose of the battery, follow local solid waste 

disposal regulations or the RBRC Battery disposal regulations 
or call the RBRC Battery Recycling Information Help Line at  
1-800-8-BATTERY (1-800-822-8837). 

 
f. Additional 

battery Information: 

 

i.  The initial charge on the battery should be for a minimum 

of 20 hours prior to use. Recharge the battery for 14-16 
hours when the red battery recharge indicator light 
comes on during use or after every 6 to 8 hours of use. 
This battery is not harmed if it is left on a continuous 
charge past the normal 14-16 hour recharge time. 
However, a continuous charging for extended periods of 
time will reduce the life of the battery. Therefore, we 
recommend that a continuous charge be limited to no 
more than 1 week. The battery will lose approximately 
20% of its capacity per month without use. 

 

6)  The GVP-115 is the set of Plugs used when cleaning the motor 

blower

. The plugs should be replaced when they are damaged, worn 

or missing. To remove the plugs:

 

 

a.  Unscrew the GVP-115 Blower Plug and Filter Plug from the 

motor blower unit. 

 

Отзывы: